WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
Maxiva ULX COFDM Series
NOTE:
The MCM card (in the TCU) contains LED’s that will flicker on and off at a ran-
dom rate indicating that there is activity on the CAN bus. If the LED’s are off or
always on, then the CAN bus is most likely not communicating. The LED pair
DS7 and DS8 are for the cabinet CAN bus (Rx & Tx respectively). LED’s DS11
& DS12 are indicators for the System CAN bus (Rx & Tx respectively).
Figure 4-9 CAN Transceiver Diagram
All fault reporting, status and metering information displayed on the GUI is sent on the
CAN bus to the MCM. Transmitter control signals are also sent via CAN but are also
sent over hardwired parallel control lines.
4.4.7
System Bus
The
system control bus
is a twenty five conductor ribbon cable which distributes the
CAN (Controller Area Network) bus and parallel control lines from the MCM card in
cabinet one to other MCM controllers in a multi cabinet system.
If system bus communications with the master TCU (in cabinet 1) are interrupted, the
cabinet bus, drive A and B busses, and BP1 through BP4 busses allow each cabinet to
operate independently.
The system bus connector J6 (on the rear of the MCM card) has the following pin
assignments:
1
8
7
6
5
4
3
2
Standby
Control
Reference
Voltage
Transmitter
Receiver
VREF
RXD
TXD
RS
CANH
CANL
GND
VCC
TXD and RXD
connect to the
CAN controller
built into the
Micro Module
(Differential CAN Bus)
Summary of Contents for Maxiva ULX COFDM Series
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...