WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
Maxiva ULX COFDM Series
Table 6-3 Power Supply Faults List
TYPE
Description
Fault Level or
Threshold
Transmitter
Action
Three
Strike
Available
in Life
Support
+VA VDC
FLT
+15V Voltage Fail-
ure
Value is more than +/-
15% of normal reading
WARNING
NO
YES
-VA VDC FLT
-15V Voltage Failure
Value is more than +/-
15% of normal reading
WARNING
NO
YES
+5 VDC FLT
+5V Voltage Failure
Value is more than +/-
15% of normal reading
WARNING
NO
YES
+3.3 VDC
FLT
+3.3V Voltage Fail-
ure
WARNING
WARNING
NO
YES
AC Mains
High
AC Mains voltage
has exceeded 10%
above nominal
WARNING
NO
YES
AC Mains
Low
AC Mains voltage
has exceeded 15%
below nominal
Any phase is greater
than +/- 5% of the
average of all three
phases
NO
YES
AC Phase
Imbalance
AC line imbalance
phase to phase
Wrong sequence
WARNING
NO
YES
AC Phase
Sequence
Wrong Phase
sequence detected
FUSE OPEN
RF MUTE,
Pump and
Heat
exchanger
turned OFF.
Transmitter
returns to ON
state automati-
cally when
fault clears.
NO
YES
MOV Fuse 1
Fuse failed on MOV
board
FUSE OPEN
WARNING
NO
YES
Summary of Contents for Maxiva ULX COFDM Series
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...