10/6/10
888-2629-200
5-11
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Maxiva ULX COFDM Series
5.6
PA and IPA (driver) Pallet Replacement
Figure 5-5 PA Module Pallet (one of four per module)
STEP 1
Turn off PA module breaker.
!
WARNING:
MODULE MAY BE HOT. ALLOW THE MODULE TO COOL BEFORE REMOVAL.
STEP 2
Wait 30 seconds for the module to cool.
STEP 3
Unscrew retaining screws and remove PA module.
STEP 4
Remove PA module cover.
STEP 5
Remove four (4) center pallet hold down screws (Allen head).
STEP 6
Remove five (5) additional pallet hold down screws (Phillips head).
Allen Screws
(torque)
Jumper
Jumper
Blue &
Gray Wires
Support