5-14
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Maxiva ULX COFDM Series
STEP 8
Install a new heat transfer pad (411-0126-000).
STEP 9
Install PS hold down screws.
STEP 10
Reconnect supply wire to WAGO.
STEP 11
Replace PA module cover.
STEP 12
Replace PA module in rack. Tighten module hold down screws.
STEP 13
Turn on PA module breaker.
5.7.2
AC/DC Converter (PS) Board Output Voltage
The output of the PS board (also referred to as the AC/ DC converter board) changes
depending on transmitter modulation type. To operate properly the output of the PS
board must be initially adjusted to 48V. This adjustment is made in the factory on each
board prior to installation into a module or shipment as a replacement part. The output
voltage can also be set in the field if a module test system is available. The optional PA
module test system part number is
971-0040-080.
5.7.2.1
Setting Voltage:
STEP 1
Follow the PS board replacement steps outlined in Section 5.7.1 on page
5-13 stopping at step 10.
STEP 2
Place the module in the module test fixture.
STEP 3
Remove JP1
STEP 4
Activate the module and set Vout to 48V using the trim pot shown in
Figure 5-6 on page 5-13.
STEP 5
Replace JP1.
STEP 6
Complete steps 10 -13 in Section 5.7.1 on page 5-13.
The TCU sends a Vtrim voltage to the PS boards. The Vtrim voltage varies depending
on the transmitter modulation selection. The PS output varies depending on the Vtrim
signal received from the TCU. The Vtrim levels are given below.
Vtrim Levels:
•
5.755V ---- 44V
•
4.122 V --- 46V
•
2.490V ---- 48V
Summary of Contents for Maxiva ULX COFDM Series
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...