WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
Maxiva ULX COFDM Series
Table 4-2 RF Detector/Pump Control/ Interlocks Card Connector J3 Pinout
Pin
Signal
Description
1
CABINET_SAFETY_INTLK
Input - Active high, cabinet safety interlock
2
CABINET_RF_MUTE_INTLK
Input - Active high, cabinet RF mute interlock
3
SYSTEM_SAFETY_INTLK
Input - Active high, system safety interlock
4
SYSTEM_RF_MUTE_INTLK
Input - Active high, system RF mute
5
PUMP_ON_CMD
Output - Active high to turn on selected pump
6
PUMP_SWITCH_CMD
Output - Pulsed active high to switch between
pumps A and B
7
PUMP_INTLK
Output, active high
8
COOLANT_FAULT
Input - connect to open drain or relay contacts.
Active low 20mA sink.
9
COOLANT_WARN
Input - connect to open drain or relay contacts.
Active low, 20mA sink.
10
PUMP_A_STATUS
Input - connect to open drain or relay contacts.
Active low 20mA sink.
11
PUMP_B_STATUS
Input - connect to open drain or relay contacts.
Active low 20mA sink.
12
PUMP_RMT/
LOCAL)_STATUS
Input - connect to open drain or relay contacts.
Active low 20mA sink.
Remote = High, Local = Low
13
EXT_VDD
+12V dc voltage supplied by pump.
14-17
GND
18-25
GNDB
Summary of Contents for Maxiva ULX COFDM Series
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...