![Harris CM-30 Installation & Operation Manual Download Page 72](http://html1.mh-extra.com/html/harris/cm-30/cm-30_installation-and-operation-manual_4019658072.webp)
NetXpress LX & CM-30 Installation & Operation Manual
4 – Configuration & Operation
Version 1, September 2010
4-26
Harris Corporation
Intraplex Products
Timeslot Activity:
The TDM bus time slot tables. Thirty two time slots appear for an E1 system, and
twenty four appear for a T1 system. The time slot color codes are:
●
Activity in Timeslot:
Green indicates a channel card is writing data to the time slot.
●
No Activity in Timeslot:
Gray indicates no channel card is writing data to the time slot.
●
Loopback in Timeslot:
Yellow indicates the time slot has been placed in either internal or
external loopback.
●
Conflict in Timeslot:
Red indicates multiple channel cards on the bus are trying to write data to
the same time slot(s).
Change loopback configuration:
Click
on a specific TDM bus row to view or change loopback
configuration operations for the bus (Figure 4-14).
Current System Mode:
Indicates whether the internal TDM busses are operating in E1 or T1 mode.
Configured System Mode:
Click
E1
or
T1
and
Submit
to change the configured system mode. If
you change the system mode, a dialog box appears (Figure 4-33) reminding you to re-configure the
FPGA image to reflect this change.
Figure 4-28. Changes to System Mode Dialog Box
Go to
System Cfg
|
Software
Images
to complete this system mode change.
Submit:
Click this button to change the current system mode.
Figure 4-29. TDM Bus Information | TDM Bus Configuration
Refresh:
Click this button to refresh the browser.