NetXpress LX & CM-30 Installation & Operation Manual
3 – Installation & Wiring
Version 1, September 2010
3-4
Harris Corporation
Intraplex Products
For IP transport in original Intraplex T1 or E1 systems, insert the CM-30 module into the same slot
number as the MA-230 module adapter in either a 3RU multiplexer or a 1RU multiplexer.
Table 3-1 gives CM-30 indicator light descriptions.
Table 3-1. CM-30 Indicator Light Descriptions
Light
Color
Description
WAN
100 Lnk/Act
Green
The Ethernet link is established at 100 Mbps, and the blinking light indicates activity.
OFF
There is no activity.
WAN
10 Lnk/Act
Green
The Ethernet link is established at 10 Mbps, and blinking light indicates activity.
OFF
There is no activity.
WAN
FD
Green
The Ethernet link is full-duplex.
OFF
The Ethernet link is half-duplex.
LAN
100 Lnk/Act
Green
The Ethernet link is established at 100 Mbps, and blinking light indicates activity.
OFF
There is no activity.
LAN
10 Lnk/Act
Green
The Ethernet link is established at 10 Mbps, and blinking light indicates activity.
OFF
There is no activity.
LAN
FD
Green
The Ethernet link is full-duplex.
OFF
The Ethernet link is half-duplex.
LPBK
Yellow
Any CM-30 loopback is enabled.
OFF
Any CM-30 loopback is disabled.
TIMG
Green
The system timing is locked.
Yellow
There is a timing alert.
Red
There is a timing alarm.
OFF
The system timing is unlocked.
ACTIVE
Green
The module is active (online).
Yellow
There is an active alert.
Red
There is an active alarm.
OFF
The module is not active (offline).
STATUS
Green
The module is not reporting an alarm or alert.
Yellow
The module is reporting an alert.
Red
The module is reporting an alarm.
3.2.2.2 CM-30 Switches and Contacts
Table 3-2 gives CM-30 switch settings.
Table 3-2. CM-30 Switch Settings
Label
Setting
Effect
ON
ON
Set the system to factory default settings.
OFF
On restart, the system reverts to LAN interface to the factory default IP address:
192.168.2.1
OFF
ON
Start up with streams out of service and default the TDM Bus Map.
OFF
On restart, the module retains the latest configurations.