Acendo BookInstallation
19
AMX RoomBook Scheduling Touch Panels - Instruction Manual
Removing the RMBK-1001/701 Panel from the Backbox
The tabs on the bottom edge of the Backbox lock down the RMBK-1001 and must be unlatched in order to remove the touch panel
from the Backbox. To do this, you ll need a thin probe such as an straightened paper clip, or the (optional) MXSA-REM-TL Bezel
Removal Tool:
NOTE:
The (optional) MXSA-REM-TL, Bezel Removal Tool (FG5968-99) provides a convenient method to release these clips. The Bezel
Removal Tool makes it easy to locate the appropriate release points for each panel size. Refer to the MXSA-REM-TL Quick Start Guide
for details.
1.
With a thin probe, carefully press straight into the access holes on the bottom of the bezel (near the center of the bottom
tabs) to disconnect the two bottom clips (FIG. 16, FIG. 17) .
.
2.
Grasp the bottom of the panel and pull gently outward until the side of the panel is free of the snap. Use your other hand to
stabilize the front of the touch panel (FIG. 18):
FIG. 16
RMBK-1001/Backbox assembly
FIG. 17
RMBK-701/BACKBOX ASSEMBLY - BOTTOM VIEW
FIG. 18
RMBK-1001/BACKBOX ASSEMBLY (RELEASING THE BOTTOM EDGE OF THE PANEL)
Bottom Clip
Bottom Clip
Insert probe (or Bezel Removal Tool) straight into access holes to push
the bottom clips in and away from the panel to release the bottom edge
Bezel (bottom edge)
Bottom Clip
Bottom Clip
Insert probe (or Bezel Removal Tool) straight into access holes to push
the bottom clips in and away from the panel to release the bottom edge
Bezel (bottom edge)
Lift the bottom edge of the panel by the plastic bezel
and gently rotate up and away from the Backbox
Note: To avoid damaging the panel, always pull on the plastic bezel - do not pull on the glass.
Note: Hold the panel to prevent it from falling once the bottom edge is free