Chimneys taller than 20’ above the connection will require a
draft test to determine if the draft is too high.
Note: The high burn draft should not exceed .85 IWC. Some
form of a restrictor plate may be required at the top of high
chimneys to reduce the draft. See
Draft Test Procedure
under
the installation section of this manual.
This boiler may be used and installed into an existing masonry
or Class A metal chimney.
Certain Canadian and local Codes may require that the
chimney be fully relined.
The venting Can Not
be installed in a chimney serving
another appliance.
The chimney should be cleaned and or inspected before
installation of the venting.
Creosote - Formation and Need for Removal -
When wood is burned slowly, it produces tar and other organic vapors,
which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue
of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an
extremely hot fire. The pellet vent pipe should be inspected at least twice monthly during the heating season to determine
if a creosote buildup has occurred. If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
Guidance on minimizing creosote formation and the need for periodic creosote removal: The chimney should be inspected
during the heating season to determine if a creosote build-up has occurred. If a significant layer of creosote has accumulated
(3mm or more) it should be removed to reduce the risk of a chimney fire.
Venting Installation
NOTe: All installation clearances and restrictions must
be adhered to.
NOTe: Read and follow all of the vent pipe manufacturers’
instructions on the proper installation and support of the
vent pipe. Adhere to all clearances.
dO NOT INSTAll A FlUe dAMPeR IN THe eXHAUST
VeNTING SYSTeM OF THIS UNIT.
dO NOT CONNeCT THIS UNIT TO A CHIMNeY FlUe
SeRVING ANOTHeR APPlIANCe.
INSTAll VeNT WAll PASS-THROUGHS AT CleARANCeS
SPeCIFIed BY THe VeNT MANUFACTUReR
INSTAllATION IS TO Be PeRFORMed BY A QUAlIFIed
INSTAlleR.
NOTe: Use only 4” diameter approved pellet venting
system. Be sure to inspect and clean exhaust venting
system frequently.
Other examples of possible installations of the venting.
36”
18”
Ceiling Height
Min. 66”
62.23
12.40
20.00
12”
36”
KeeP COMBUSTIBle MATeRIAlS SUCH AS GRASS,
leAVeS, eTC. AT leAST 3 FeeT AWAY FROM THe
POINT dIReCTlY UNdeR THe VeNT TeRMINATION.
(BeTWeeN THe VeNT ANd THe GROUNd)
WARNING
!
KeeP COMBUSTIBleS AWAY FROM FlUe OUTleT.
CAUTION
!
12”
36”