3-90-07205R26_10/14
Quick Reference (Auto-
light)
1 T
urn Mode Selector to OFF
.
2
Use
heat
exchanger cleanout
rods
to
clean
the
heat
exchanger
tubes.**
3 Scrape the air holes in the burnpot.**
4 Fill the hopper with pellets.
5 T
urn Feed
Adjuster to “T
est”.*
6 Check the Combustion Blower and Feeder Motor for operation.*
7 T
urn Feed
Adjuster back to the #4 setting.
8 T
urn the MAX. T
eMP
. dial to the desired temperature.
9 T
urn MIN. T
eMP
. dial to the desired settings.*
10 Flip the igniter switch to
Auto.*
The
boiler
will
ignite
if
the temperature of
the boiler
water is less than
the temperature set on MAX. T
eMP
. dial..
*See the
section
on
Operation
for
information
about Manual
lighting and
emergency Power
.
**S
ee th
e sect
io
n o
n M
ai
nt
en
an
ce f
or mo
re
details about cleaning.