ESP Control

3  blinks:

  Indicates  that  the  ESP  (Exhaust  Sensing 

Probe)  has  failed,  has  a  broken  connection,  or  has 

gone  out  of  range  too  many  times. This  requires  a 

manual reset*.

4 blinks:

 Can occur only in Room Temp Mode and 

indicates Room Sensing Probe failed or not installed. 

If a Room Sensing Probe is then installed, the status 

light will automatically reset.

NOTE:  Unit  will  not  start  in  "AUTO"  with  this  status 

error.

5 blinks (In Igniter Auto. mode Only):

  Indicates that 

the unit has failed to light within the 36 minute start 

cycle. To reset - Turn Mode Selector to "OFF", then turn 

to either mode again.)

6 blinks 

: Indicates that the control has calculated poor 

or incomplete combustion occurring for more than 50 

minutes. 

A six blink status may be set if the stove is allowed to 

run out of pellets. To reset, turn mode selector to "OFF" 

then back on to the desired mode. If the unit was not 

out of pellets, see Troubleshooting section, Page 33, 

for more details.

* manual reset

- disconnect power cord for a few sec-

onds and reconnect. If error still occurs call your Dealer.

Feed adjuster

Sets the maximum feed 

rate

Test

Runs all motors at full 

speed for one minute 

to check operation. 

Afterwards the 

control will simulate 

a minimum burn with 

the combustion blower 

remaining on low.

Distribution Blower 

speed adjustment 

range. 

L = low

H = high

Variable speed 

anywhere between L 

and H; although as the 

stove temp. goes up , so 

does the L and H scale.

Temp dial

Allows you to adjust the room temperature setting, in Room 

Temp  Mode,  using  the  outer  scale  marked  in  degrees 

Fahrenheit. It also allows you to adjust the stove temperature 

setting, while in Stove Temp Mode, using the inner scale 

marked from 1 to 7.

Mode Selector 

Allows you to choose between 

Room Temp Mode, Stove Temp 

Mode, or OFF. Also allows you 

to  vary  the  distribution  blower 

speed by turning the knob to the 

high or low side of each mode.

Power Light

Indicates power to the 

control.

     

Indicates power to the 

feed motor.

 Indicates power to 

combustion blower

Status Light

Will be lit in either stove 

or room temp mode 

when pointer is not 

within off position band 

except after normal 

shut down. Blinks to 

indicate errors listed  

below.   

Indicates power to 

distribution blower.

Dealer Diagnostic Port

For dealer maintenance  

only. Requires special 

DDM monitor supplied 

to Harman Dealers 

exclusively.

Status light error messages:

Indicates igniter is on.

Igniter switch

Set to appropriate 

Start-Up mode.

Summary of Contents for Accentra

Page 1: ...ESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to determine the need fo...

Page 2: ...nstall and use only in accordance with the manufacturer s installa tion and operation instructions Contact local building or fire officials about restrictions and inspection in your area WARNING FOR M...

Page 3: ...xible inox double peau 125 mm l aide d un adaptateur ad quat comme indiqu dans la notice d utilisation Ne pas raccorder ce po le un conduit de chemin e d j utilis pour un autre appareil FONCTIONNEEXCL...

Page 4: ...ment to operate if the view door is open 4 Adjust Feed Rate If this is your first fire or you are trying different pellets set the feed adjuster to 4 Fig 1 This is a conservative number and will proba...

Page 5: ...xact room temperature Therefore as it gets colder more pellets will be burned automatically The distribution blower speed will vary according to the position of the mode selector pointer and fire size...

Page 6: ...1 Fines are small pieces of broken pellets sawdust Fines do not flow easily and often build up on the hopper funnel bottom angles These fines can be pushed into the feeder opening and then fill the h...

Page 7: ...ing operation with the temperature dial set at 4 or less the distribution fan will not operate A 4 on the temperature dial and a 4 on the feed adjuster is approximately 80 output It is not necessary t...

Page 8: ...Runs all motors at full speed for one minute to check operation Afterwards the control will simulate a minimum burn with the combustion blower remaining on low Distribution Blower speed adjustment ra...

Page 9: ...om the underside with a 3 8 socket The cast top and lid assembly bolt down bars On each side of the stove body underneath the cast top are 2 1 4 flange head bolts See Fig 12 These bolts pull the cast...

Page 10: ...ts flat on the firebox bottom Rotate the edge of the heat exchanger closest to the burnpot until it is in front of the burnpot Tip the top of the heat exchanger toward the middle of the opening until...

Page 11: ...The left and right side wings should be standing up aligned with the side of the mounting frame and slid inward towards the center Note The wings mount on the rear side below the notch and on the fron...

Page 12: ...ir sensor Harman highly recommends that the room sensor be installed If you are installing the room sensor as a wall sensor the long black 2 wire cable must be wire tied to the power cord This wire is...

Page 13: ...g tip is in the middle of the front return air opening See Fig 25 Wire tie the sensor wire to the inside of the mounting frame up to the cord grounding location Follow the power wiring to where you ma...

Page 14: ...ed insulation wrapped around the flue pipe from the mounting frame upward Fig 29 Flue Pipe Stub Assembly Floor protection must be used from hearth opening to 6 152mm in front of door glass and 6 152mm...

Page 15: ...losed Connecting the power cord The white from the mounting frame connects to the white of the insert body The black from the mounting frame connects to the brown of the insert body 16 Place the stove...

Page 16: ...t the silicone sponge gasket on the top edge of the hopper If it is okay put the cast top hopper lid assembly see Fig 35 into place over the hopper Make sure the hopper lid is open to install the top...

Page 17: ...reely for control board access 22 Slide the stove body into the mounting frame Note The two spring latches on the bottom right and left side of the body must be in the proper position to enter the lat...

Page 18: ...bracket with the two thumb screws provided Center the log in the firebox opening with the bottom front edge over the thumb screws The log branch tips only rest on the bracket arms for easy installati...

Page 19: ...eeder motor or the igniter to operate After the installation is completed but before the first fire is lit check and record the high and low draft readings A simple draft test should be performed afte...

Page 20: ...ra in a mobile home several requirements must be followed 1 The unit must be bolted to the floor This can be done with 1 4 lag screws through the 5 holes in the base plate shown in Fig 26 2 The unit m...

Page 21: ...NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Avoiding Smoke and Odors Negative Pressure Shut down and Power Failure To reduce the probability of back drafting or burn back in the...

Page 22: ...mney Intake Extension Part 1 00 674104 Vent Configurations To reduce probability of reverse drafting during shut down conditions Hearth Home Technologies strongly recommends Installing the pellet vent...

Page 23: ...CONNECTOR PIPE MAY NOT PASS THROUGH CONCEALED SPACES INCLUDING AN ATTIC ROOF SPACE CLOSET FLOOR OR CEILING Fig 49 Height of existing hearth The chimney top must be capped to prevent rain and or snow...

Page 24: ...r 30 feet A3 or 4 PL vent pipe should be used with the needed swivel flue stub NOTE The flue stub insulation wrap must still be used with this method See page 14 Fig 27 29 With a 100 outside air kit t...

Page 25: ...manufactured fireplace right down to the outer sheet metal which must be left in place for floor protection under the insert mounting frame Floor protection guidelines as listed on page 14 must also b...

Page 26: ...56 Accentra Insert Zero Clearance Cabinet Be sure to use approved pellet vent pipe wall and ceiling pass through fittings to go through combustible walls and ceilings Be sure to use a starting collar...

Page 27: ...is fully open on a minimum of 2 sides beneath the floor Venting Requirements for Terminating the Venting WARNING Venting terminals must not be recessed into a wall or siding NOTE Only PL or L vent pi...

Page 28: ...should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pend...

Page 29: ...er element Figure 60 The igniter is made to be removable for service by insulated male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads t...

Page 30: ...n chamber You will need to use the entire length of the cleaning brush handle to properly clean this tube Cleaning the Heat Exchanger tubes The accordion heat exchanger surfaces are the primary source...

Page 31: ...he fan blade by pulling it directly away from the blower housing The cord on the motor is long enough to allow the motor to be set down on the black plastic fan cover This allows for easy access to in...

Page 32: ...the control sends a status alert and at the same time the unit goes down to minimum feed minimum burn as a safety condition Accentra Insert Motor Component Locations Accentra Pellet Insert Safety Devi...

Page 33: ...the combustion through feed settings and ESP temperatures When the control board has calculated poor or incomplete combustion it will shut down the unit as a safety feature Poor or incomplete combusti...

Page 34: ...ellets Outside Air Size 3 inches Fuse Rating 6 amp BTU Range 0 to 42 000 Feed Rate 75 lbs hr on minimum on maintenance 5 lbs hr on maximum Vent Size 4 inch Pellet Vent Pipe standard 3 inch Pellet Vent...

Page 35: ...E WHITE BONDED TO STOVE WING GREEN WIRE IS GROUND RED GREEN 6 AMP GLASS FUSE HARMAN ACCENTRA INSERT PELLET STOVE 1 90 00674 B R O W N GREEN YELLOW WHITE GREEN WIRE IS GROUND BONDED TO STOVE BODY BLACK...

Page 36: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Page 37: ...as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated...

Page 38: ...90 00676 3 Goldenfire june 2011 1 90 00676 4 Metallic Blue jan 2010 1 90 00676 5 Honey Glo june 2009 1 90 00676 10 Mojave Red jan 2010 1 90 00676 12 Forest Green jan 2010 1 90 00675 2 Charcoal june 2...

Page 39: ...it Kit 1 10 01782A Y 1 00 232108 Y Post 008244667 1 10 01782A Y Feeder Hopper Assembly Height 24 Pre 008240096 1 10 674063A Y 008240096 thru 008244667 Must also order Switch retrofit Kit 1 10 01780A Y...

Page 40: ...9 Y Glass 3 40 674090 Y Glass Clip Pkg of 4 1 00 249140 Y Rope 3 16 Gasket w PSA Glass 10 Ft 1 00 1186258229 Y Rope 3 8 Gasket Door 30 Ft 1 00 00888 Y Wood Handle Bolt Pkg of 2 1 00 00247 Y 27 Cast Bo...

Page 41: ...37 6 Feed Cover and Gasket 2 Sets 1 00 677152 Y 37 7 Auger Assembly 3 50 00465 Y 37 8 Cam Bearing 3 31 3014 Y 37 9 Bearing Flange w Hardware 1 00 04035 Y 37 10 Bracket Gear Motor Pkg of 2 1 00 01534 Y...

Page 42: ...38 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 38 8 Ultra Feeder Weldment 1 10 724132 Y 38 9 UL Feeder Pusher Arm 1 10 677187W Y 38 10 Fines Deflector No longer available 2 00 677138 10 38 1...

Page 43: ...0 674038B Diagnostic Display Module 3 20 05401 Y DDM Replacement Cable 1 00 05402 Disconnects Male 1 4 Pkg of 25 1 00 00957 Y Disconnects Male 3 16 Pkg of 25 1 00 521102 Y Ball Plungers Pkg of 3 3 31...

Page 44: ...eration Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition In Automatic setting units equipped with automat...

Page 45: ...to dry and tends to cool the appliance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system Size Pellets are either 1 4 i...

Page 46: ...to 2 or 3 Set temperature knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed...

Page 47: ...47 3 90 00674R20_08 12 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 48: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Reviews: