Graduation Size Parameter
The Graduation Size is the Minimum increment displayed by the instrument. The Base Graduation Number can be
calculated by dividing the Total Load Cell Capacity by 10,000.
For example, with two decimal points selected, a graduation size of 10 will display increments of .10 units and the
graduation size .50 will display increments of.50 units. For a scale with 10,000 capacity, graduation size = 1
RANGE:1, 2, 5,10, 20, 50, 10, 200, 500, 1000 (default 1)
On the Web page Or Using the Front Panel Display
: from the Decimal Point pull-down list, select the decimal position
for this instrument or select from the list of graduation values supported using the arrow keys.
Instrument ID
Use this parameter to assign a meaningful name to the system to make it easier to identify on a network. The assignment
applies to the Gateway Module only, channels connected to the Gateway may also be assigned a name by following the
Naming the Weight Processing Modules section located in the beginning of this chapter.
Motion Tolerance Parameter
The value you enter for Motion Tolerance sets the amount of deviation to allow for your process. This value must be
greater than or equal to the Graduation Sizes. We recommend 3 times the graduation size.
The base motion number can be calculated by using the following formula:
Base Motion Number = (Total Load Cell Capacity x 0.0003)
RANGE: .000001 - 999999 (default 10)
On the
Web page or Using the
Front Panel Display
: enter the value in the text box provided or input the desired motion
tolerance value using the arrow keys.
Operator ID Parameter
The Operator ID is the ID of the user who is going to operate the Weight Processor or service the instrument. Select three
letters or numbers or any combination of letters and numbers that adequately identifies the user.
On the
Web page or Using the
Front Panel Display
: enter the value in the text box provided or input a value using the
arrow keys, then pressing the enter button to save.
Unit (of Measure) Parameter
The Unit (of measure) parameter sets the scale to either English or Metric units. The Selections are:
Ounces
Pounds
Ton
Gram
Kilogram
Metric Ton
Summary of Contents for HI 6600-EIP
Page 16: ...HI 6600 Series Modular Sensor System User Guide Page 16...
Page 44: ...HI 6600 Series Modular Sensor System User Guide Page 44...
Page 97: ...HI 6600 Series Modular Sensor System User Guide Page 97 A ElectricalandMechanicalReview...
Page 107: ...HI 6600 Series Modular Sensor System User Guide Page 107 H Mechanical Installation...
Page 108: ...HI 6600 Series Modular Sensor System User Guide Page 108 J Electrical Inspection...
Page 109: ...HI 6600 Series Modular Sensor System User Guide Page 109 K InstallationCheckPoints...
Page 128: ...HI 6600 Series Modular Sensor System User Guide Page 128...