HI 6600 Series Modular Sensor System User Guide
Page | 9
The system is used for front end signal processing of strain-gage type sensors and load cells for all types of
industrial and machine weighing applications. Operating blind or with an optional display, the Modular
Sensor System conditions, converts and communicates stable processed weight readings from connected
load sensors or scales to a variety of control and monitoring systems.
The HardyNet Gateway Module (HGM or HI 6600) offers users many communication choices including
Ethernet TCP/IP, Modbus RTU, Modbus TCP and either EtherNet/IP or Profibus-DP.
The HI 6600 series can be used with or without an optional Hardy HI 6110 display. The display is a bright
4.3” high-contrast LCD capable of high-resolution graphics and help text discrete messaging. The HI 6110
display can be panel mounted near the Gateway Module or remotely up to 100 feet away to provide a user
interface for operating, calibrating or setting-up the system.
The modular array, small enclosures and low power consumption enable high density cabinet design for
systems that require up to 28 channels of processed weight.
Summary of Contents for HI 6110
Page 16: ...HI 6600 Series Modular Sensor System User Guide Page 16 ...
Page 44: ...HI 6600 Series Modular Sensor System User Guide Page 44 ...
Page 97: ...HI 6600 Series Modular Sensor System User Guide Page 97 A ElectricalandMechanicalReview ...
Page 107: ...HI 6600 Series Modular Sensor System User Guide Page 107 H Mechanical Installation ...
Page 108: ...HI 6600 Series Modular Sensor System User Guide Page 108 J Electrical Inspection ...
Page 109: ...HI 6600 Series Modular Sensor System User Guide Page 109 K InstallationCheckPoints ...
Page 128: ...HI 6600 Series Modular Sensor System User Guide Page 128 ...