Wagenbouw HAPERT
35
5.2
T
IPPING SYSTEM
5.2.1
T
IPPING RANGE
Tipping range, tipping backwards
To the end of the cylinder
Tipping range, tipping sideways (only type
COBALT HM and )
Until the safety cable is tight or by
means of a stop switch (electric
operation)
5.2.2
H
YDRAULIC PUMP
Hand pump COBALT
HB, HM, and
Hand pump INDIGO
HT and INDIGO LT
(double-acting)
Electric pump COBALT HB,
HM, and INDIGO
HT
Nominal pressure
180 bar
250 bar
170 bar
Pressure relief valve
setting
220 bar
300 bar
200 bar
Oil reservoir
Volume
Effective volume
5 litres
4.5 litres
1 litre
1 litre
5 litres
4.5 litres
Hydraulic oil
Tellus 46, Shell HM46 or
similar
Tellus 46, Shell
HM46 or similar
Tellus 46, Shell HM46 or
similar
Battery
Type
Capacity
N/A
N/A
12 V starter battery
90 Ah
Electric motor capacity
N/A
N/A
2 kW
Maximum sound level
<70 dB(A)
<70 dB(A)
<70 dB(A)
5.3
P
HYSICAL CONDITIONS OF USE
Ambient temperature:
* Working
* During transport/storage
-5 to +40 degrees Celsius (with
hydraulic system)
-25 to +40 degrees Celsius
-25 to +55 degrees Celsius
Relative humidity (RH)
30% to 95%, non-condensing
Lighting
E4 / normal ambient lighting
The trailer is not suitable for use in an explosion-hazardous environment.