4
English
anti-pollution function
6
6 6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
6
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6
Do not allow the streams of the shower touch sen-
sitive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
6
The product may not be used as a holding handle. A
separate handle must be installed.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
•
Important!
The fitting must be installed, flushed and
tested after the valid norms.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer’s indications of the dowel
manufacturer have to be taken into account.
• The filter insert must be use to protect the shower
against incoming dirt by pipework. Incoming dirt leads
to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee
claims.
Technical Data
Operating pressure:
max.1 MPa
Recommended operating pressure:
0,15 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150 mm
Connections G 1/2:
cold right - hot left
Symbol description
Adjustment
(see page 38)
After the installation, the output temperature of
the thermostat must be checked. A correction
is necessary if the temperature measured at
the output differs from the temperature set on
the thermostat.
Do not use silicone containing acetic acid!
Safety Function
(see page 39)
The desired maximum temperature for examp-
le max. 42º C can be pre-set thanks to the
safety function.
Maintenance
(see page 44)
• To guarantee the smooth running of the
thermostat, it is necessary from time to time
to turn the thermostat from total hot to total
cold.
• The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional regu-
lations (at least once a year).
Dimensions
(see page 31)
Flow diagram
(see page 31)
Spare parts
(see page 43)
Cleaning
(see page 41)
Operation
(see page 40)
Assembly see page 32
Summary of Contents for Raindance E Showerpipe
Page 31: ...31...
Page 32: ...32 X 1200 mm 1100 mm 1000 mm Y 2240 mm 2140 mm 2040 mm Z 2320 mm 2220 mm 2120 mm...
Page 33: ...33 1 3 6 5 2 27 mm 4 5 mm 5 mm S i l i k o n 1 2...
Page 34: ...34 8 11 10 9 10 mm 10 mm S i l i k o n 7 5 mm 5 mm 12 1 2...
Page 36: ...36 21 18 20 19 22 1 2 3 14 x 1 5mm 4 mm 2 Nm 6 mm 2 Nm 5 mm 2 Nm 4 1 2...
Page 37: ...37 24 26 3 mm 1 5 Nm 25 3 mm 1 5 Nm 23 1 3 2 4 mm 1 5 Nm...
Page 38: ...38 1 3 mm 1 5 Nm 2 3 mm 3...
Page 39: ...39 1 4 2 3 3 mm 3 mm 4 mm 5 3 mm 1 5 Nm 4 mm 1 5 Nm 3 mm 1 5 Nm 6...
Page 40: ...40 1 2 90 90 1 2 3 1 2 3...