126
3.2 Maintenance-free battery with battery display
:
Users need to add a little water and
electrolyte in the use.
3.2.1. Battery check
When the battery volume status is normal and electrolyte density reaches the standard, the small
ball is in green; when the battery volume is insufficient and electrolyte density drops, the color is
white; if the ball is in red, that means the electrolyte is badly insufficient, you should check whether
there is fracture, leakage or fault to battery.
1
:
Green
:
Sufficiently charged.
2
:
White
:
Insufficiently charged.
3
:
Red
:
Replace battery.
The indicator of battery refers to the prompt on the battery label.
3.2.2. Battery maintenance
1)
Insure the green status visual in inner indicator;
2)
Disconnect negative earth wire to avoid discharging by additional current release;
3)
Keep the battery charged completely when the battery cannot be removed from the truck
;
4)
Make a general schedule, charge every 30-45 days if truck is not used during this period;
5)
Check battery when the green status of indicator at battery are invisible,
charge, add distilled
water or replace battery.
3.3 Ordinary lead-acid battery
:
Users need to notice the liquid level and add water and
electrolyte timely in the use.
3.3.1. Battery check
As the forklift is used in a high temperature ambient, and the battery easily consumes water, you
should do pay attention to the liquid level when using the forklift. There is an aperture for adding
liquid in the cover of the battery. Please add enough water up to the UPPER LEVEL when the liquid
level is below the LOWER LEVEL and be sure the water is not so much that spill out to erode your
forklift.