MINIVATOR SIM INSTALLATION MANUAL
29
E
N
G
L
IS
H
Code:
N/A
Meaning: Description:
Lift is in “sleep mode”
to conserve battery power.
Code:
U
Meaning: Description:
No float indication V1.19 Faulty power supply.
software and later only.
Code:
Y
Meaning: Description:
Main board error. The main control board
has a fault.
Code:
o
Meaning: Description:
Default Eeprom. The Eeprom has been reset
to its default value (Flash Failure).
Code:
P
Meaning: Description:
PS no reply. Powered swivel did not respond.
Code:
N/A
Meaning: Description:
Over current.
Code:
r
Meaning: Description:
No charge current.
Activated.
P
u
.8.
NOTE: If the display is showing
anything but the diagnostic codes
listed it requires resetting.
Drive the lift off the charge contacts.
Turn the main switch on the unit off
for 10 seconds and then back on.
Telephone fault finding action:
None.
On site fault finding action:
Press toggle or handset button to wake lift.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check power supply.
Telephone fault finding action:
Check that power supply is switched on from mains supply.
If yes send engineer.
On site fault finding action:
Check power supply.
Telephone fault finding action:
NOT YET ACTIVE.
On site fault finding action:
NOT YET ACTIVE.
Telephone fault finding action:
Send engineer with a service exchange power pack.
On site fault finding action:
Replace power pack.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Appendix 1
05029 Sim Install MULTI ENG:Layout 1 17/06/2010 14:47 Page 29