26
MINIVATOR SIM INSTALLATION MANUAL
Code:
None
Meaning: Description:
No display.
Telephone fault finding action:
Ask client to press toggle and see if display comes on.
Ask if main power switch on the lift is turned on.
If does not correct fault – send engineer.
On site fault finding action:
Check batteries. Check display board is working correctly.
Check comms circuit for short circuits.
Code:
2
Meaning: Description:
Off charge.
Code:
4
Meaning: Description:
Top pressure – Right hand. Safety edge (up/down direction)
Bottom pressure – Left hand. activated – footplate.
Code:
3
Meaning: Description:
Top stop – Right hand. End limits activated.
Bottom stop – Left hand.
Code:
1
Meaning: Description:
Requires charge.
Code:
Okay
Meaning: Description:
Charging.
Code:
0
Meaning: Description:
Final limit activated. Key switch, seat swivel, OSG,
overrun activated, short circuit.
3
1
0
2
4
Appendix 1
Diagnostic codes
Telephone fault finding action:
Ask client to tap footplate edges. If this does not correct the fault
– send engineer.
On site fault finding action:
Check footplate leading edge.
Telephone fault finding action:
Ask client to tap trunnion guards in case they are stuck.
If this does not correct the fault – send engineer.
On site fault finding action:
Check end limit circuit and trunnion guards.
Telephone fault finding action:
Ask client to drive lift to charge contacts – if ‘Okay’ code does
not show send engineer.
On site fault finding action:
Drive lift to charge contacts. Check charging circuit if ‘Okay’
code not displayed.
Telephone fault finding action:
Ask client to drive lift to charge contacts – if ‘Okay’ code does
not show send engineer.
On site fault finding action:
Drive lift to charge contacts. Check charging circuit if ‘Okay’
code not displayed.
Telephone fault finding action:
Ask client to ensure key switch is on and seat is fully swivelled to
drive position. If this does not correct the fault – send engineer.
On site fault finding action:
Test each item in turn to determine fault.
Telephone fault finding action:
If no other code is displayed and lift does not drive – are the arms
fully down? Ask client if 8 or 9 show in the display when the toggle
switch is activated – if no send an engineer.
On site fault finding action:
Send engineer to check toggle and arm circuit.
05029 Sim Install MULTI ENG:Layout 1 17/06/2010 14:47 Page 26