34
MINIVATOR 2000 INSTALLATION MANUAL
Appendix 2
Code:
Meaning:
d
Relay not open (stopped).
Description:
The main power relay is welded closed.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
Meaning:
F
F
Brake semi-conductor failed.
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
Meaning:
g
Brake not connected.
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check brake.
Code:
Meaning:
H
H
Relay not open (Pre delay).
Description:
The main power relay is closed early.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
Meaning:
n
Half speed.
Description:
Telephone fault finding action:
Send engineer if permanently showing.
On site fault finding action:
Check reed switches and dipswitch settings.
Check battery voltage.
Code:
Meaning:
L
L
Current limit exceeded.
Description:
Telephone fault finding action:
Check client understands loading limits.
Send engineer if persistent fault.
On site fault finding action:
Check motor and track for obstructions.
Code:
Meaning:
E
E
Relay not closed.
Description:
The main power relay did not close.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check battery voltage and replace if necessary,
otherwise replace main board.
Code:
Meaning:
L
J
Hinge interlock switch error.
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace hinge interlock roller switch.