![background image](http://html.mh-extra.com/html/hand-held-products/2020/2020_user-manual_589664271.webp)
2020/4820/4820 i User’s Guide
16 - 3
Relink Time-Out
Relink Time-Out controls the idle time between re-link attempts. An attempt to
link an image scanner to a base unit typically lasts up to 5 seconds. This is the
time when the image scanner is actually attempting to contact base unit. Relink
Time-Out controls the amount of time, in seconds, that elapses between the end
of one connection attempt and the start of the next.
Note: The length of time for an attempt depends on the number of image
scanners connected to a base unit. An extra 7 seconds may be required
when a connection is successful.
Scan the
Relink Time-Out
barcode, then scan the number of seconds for the
setting (from 1-100) from the inside back cover. Scan Save to save the setting.
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values:
When the image scanner goes out of range, the image scanner repeatedly
attempts to connect to base unit. Each attempt consists of approximately 5
seconds of active time followed by 3 seconds of idle time. After one hour, the
image scanner powers off and batch mode data is lost.
Maximum Link Attempts set to 15
Other values at default setting:
When the image scanner goes out of range, 15 attempts are made to link to
the base unit. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2
minutes, the image scanner stops trying to connect to the base unit, but retains
any barcodes that may have been saved in batch mode. After one hour, the
image scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default setting:
When the image scanner goes out of range, no action is taken to re-link. When
the trigger is pulled, 15 attempts are made to link to the base unit. Each
attempt consists of approximately 5 seconds of active time followed by 3
seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the
image scanner stops trying to connect to the base unit, but retains any
barcodes that may have been saved in batch mode. After one hour, the image
scanner powers off and batch mode data is lost. Refer to
Auto Reconnect
Mode
, page 16-1, to review other events that can start the re-link process.
Relink Time-Out
Summary of Contents for 2020
Page 1: ... User s Guide 2020 4820 4820 i 2D Cordless Imaging System ...
Page 7: ...Base Compliance Label locations Item Number Serial Number and Revision Information location ...
Page 8: ......
Page 20: ...xii ...
Page 56: ...2 26 2020 4820 4820 i User s Guide ...
Page 80: ...3 24 2020 4820 4820 i User s Guide ...
Page 112: ...5 8 2020 4820 4820 i User s Guide ...
Page 118: ...6 6 2020 4820 4820 i User s Guide ...
Page 170: ...7 52 2020 4820 4820 i User s Guide ...
Page 204: ...9 14 2020 4820 4820 i User s Guide Exit Selections Save OCR Template Discard OCR Template ...
Page 242: ...12 26 2020 4820 4820 i User s Guide ...
Page 252: ...13 10 2020 4820 4820 i User s Guide ...
Page 273: ......
Page 277: ...OCR Programming Chart a e d g c h t l Discard Save r ...