6 - 2
2020/4820/4820 i User’s Guide
Note: The wildcard for all terminal types is 099.
Step 4. Code I.D.
In the
Symbology Chart,
beginning on page A-1, find the symbology to
which you want to apply the data format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the
Programming Chart
inside the back cover of this manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
for this symbology. Scan the four digit data length from the
Program-
ming Chart
inside the back cover of this manual. (Note: 50 characters is
entered as 0050. 9999 is a universal number, indicating all lengths.)
Step 6. Editor Commands
Refer to
Data Format Editor Commands
(page 6-2). Scan the symbols
that represent the command you want to enter. 94 alphanumeric char-
acters may be entered for each symbology data format.
Step 7.
Scan
Save
from the
Programming Chart
inside the back cover of this
manual to save your entries.
Other Programming Selections
•
Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
primary format, scan
0
from the
Programming Chart
inside the back cover of
this manual. If you are clearing an alternate format, scan
1
,
2
, or
3
, depending
on the alternate format you are clearing. Scan the Terminal Type and Code
I.D. (see
Supported Terminals
on page 2-8), and the barcode data length for
the specific data format that you want to delete. All other formats remain
unaffected.
•
Save
from the
Programming Chart
inside the back cover of this manual
This exits, saving any Data Format changes.
•
Discard
from the
Programming Chart
inside the back cover of this manual
This exits without saving any Data Format changes.
Data Format Editor Commands
Send Commands
F1 Send all characters followed by “xx” key or function code, starting from cur-
rent cursor position.
Syntax = F1xx
(xx stands for the hex value for an
ASCII code, see
Code Page Mapping of Printed Barcodes
on page A-6.)
F2 Send “nn” characters followed by “xx” key or function code, starting from
current cursor position.
Syntax = F2nnxx
(nn stands for the numeric value
(00-99) for the number of characters and xx stands for the hex value for an
ASCII code. See
Code Page Mapping of Printed Barcodes
on page A-6.)
F3 Send up to but not including “ss” character (Search and Send) starting from
current cursor position, leaving cursor pointing to “ss” character followed by
“xx” key or function code.
Syntax = F3ssxx
(ss and xx both stand for the
Summary of Contents for 2020
Page 1: ... User s Guide 2020 4820 4820 i 2D Cordless Imaging System ...
Page 7: ...Base Compliance Label locations Item Number Serial Number and Revision Information location ...
Page 8: ......
Page 20: ...xii ...
Page 56: ...2 26 2020 4820 4820 i User s Guide ...
Page 80: ...3 24 2020 4820 4820 i User s Guide ...
Page 112: ...5 8 2020 4820 4820 i User s Guide ...
Page 118: ...6 6 2020 4820 4820 i User s Guide ...
Page 170: ...7 52 2020 4820 4820 i User s Guide ...
Page 204: ...9 14 2020 4820 4820 i User s Guide Exit Selections Save OCR Template Discard OCR Template ...
Page 242: ...12 26 2020 4820 4820 i User s Guide ...
Page 252: ...13 10 2020 4820 4820 i User s Guide ...
Page 273: ......
Page 277: ...OCR Programming Chart a e d g c h t l Discard Save r ...