background image

™ 

User’s Guide

2020/4820/4820 

i

2D Cordless Imaging System

Summary of Contents for 2020

Page 1: ... User s Guide 2020 4820 4820 i 2D Cordless Imaging System ...

Page 2: ...ein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Hand Held Products 2005 2008 Hand Held Products Inc All...

Page 3: ...erate this equipment Agency Compliance Statements Canadian Compliance This Class B digital apparatus complies with Canadian ICES 003 Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 3 To prevent radio interference to the licensed service thi...

Page 4: ...l essential requirements of the R TTE Directive 1999 5 EC and the 2006 95 EC Low Voltage Directive For further information please contact Hand Held Products Inc Nijverheidsweg 9 13 5627 BT Eindhoven The Netherlands Hand Held Products shall not be liable for use of our product with equipment i e power supplies personal computers etc that is not CE marked and does not comply with the Low Voltage Dir...

Page 5: ... issued a GS certificate showing compliance to IEC 60950 1 and IEC 60825 1 UL and cUL Statement UL and cUL listed UL60950 1 and CSA C22 2 No 60950 1 03 C Tick Statement Conforms to AS NZS 3548 C Tick number N10410 Mexico Safety approval conforms to NOM 019 Comision Federal de Telecomunicaciones radio approval Solids and Water Protection The 2020 and 4820 have ratings of IP41 immunity of foreign pa...

Page 6: ...Required Safety Labels Scanner Compliance Label locations Item Number Serial Number and Revision Information location ...

Page 7: ...Base Compliance Label locations Item Number Serial Number and Revision Information location ...

Page 8: ......

Page 9: ...nking Image Scanner to Base 1 8 Communication Between the Cordless System and the Host 1 8 Reading Techniques 1 10 Chapter 2 Programming the Interface Introduction 2 1 Programming the Interface Plug and Play 2 1 Keyboard Wedge Connection 2 1 Laptop Direct Connect 2 1 RS 232 2 2 Wand Emulation Plug Play 2 2 IBM 4683 Ports 5B 9B and 17 Interface 2 3 IBM SurePos 2 4 USB PC or Macintosh Keyboard 2 5 U...

Page 10: ... 25 Chapter 3 Basic System Operation Cordless Base 3 1 RF Radio Frequency Module Operation 3 1 Cordless Image Scanner 3 1 System Conditions 3 2 Linking Process 3 2 Image Scanner Is Out of Range 3 2 Image Scanner Is Moved Back Into Range 3 2 Out of Range and Back into Range with Data Accumulation Mode On 3 2 Base Charge Mode 3 3 Beeper and LED Sequences and Meaning 3 4 Image Scanner LED Sequences a...

Page 11: ...of Setting Up a Mobility System Device Dol phin 7900 running Windows Mobile 5 0 3 13 Changing the Image Scanner s Bluetooth PIN Code 3 20 Starting ScanWedge 3 22 Out of Range Alarm 3 22 Duration 3 22 Alarm Sound Type 3 22 Data Accumulation Mode 3 23 Batch Mode Transmit Delay 3 23 Chapter 4 Output Good Read Indicators 4 1 Beeper Good Read 4 1 Beeper Volume Good Read 4 1 Beeper Pitch Good Read 4 2 B...

Page 12: ...ed Symbology 4 14 Output Sequence Overview 4 17 Output Sequence Editor 4 19 Require Output Sequence 4 19 Multiple Symbols 4 20 No Read 4 20 Print Weight 4 21 Video Reverse 4 21 Working Orientation 4 22 FIPS Encryption Indicators 4 23 LED and Beeper Indicators 4 23 Scanner Indicators 4 23 Base Indicators 4 24 Chapter 5 Data Editing Prefix Suffix Overview 5 1 To Add a Prefix or Suffix 5 1 To Clear O...

Page 13: ...ormat Editor 6 4 Data Formatter 6 5 Alternate Data Formats 6 5 Chapter 7 Symbologies All Symbologies 7 2 Message Length Description 7 2 Codabar 7 3 Codabar Start Stop Characters 7 3 Codabar Check Character 7 3 Codabar Concatenation 7 4 Codabar Message Length 7 5 Code 39 7 5 Code 39 Start Stop Characters 7 6 Code 39 Check Character 7 6 Code 39 Message Length 7 7 Code 39 Append 7 7 Code 32 Pharmaceu...

Page 14: ...d 7 16 Code 11 Message Length 7 16 Code 128 7 16 ISBT 128 Concatenation 7 17 Code 128 Message Length 7 17 Code 128 Code Page 7 18 Telepen 7 18 Telepen Output 7 19 Telepen Message Length 7 19 UPC A 7 19 UPC A Check Digit 7 20 UPC A Number System 7 20 UPC A Addenda 7 21 UPC A Addenda Required 7 21 UPC A Addenda Separator 7 21 UPC A EAN 13 with Extended Coupon Code 7 22 UPC E0 7 22 UPC E0 7 22 UPC E0...

Page 15: ...h 7 30 Plessey Code 7 30 Plessey Message Length 7 31 GS1 DataBar Omnidirectional 7 31 GS1 DataBar Limited 7 32 GS1 DataBar Expanded 7 32 GS1 DataBar Expanded Message Length 7 33 PosiCode 7 33 PosiCode Message Length 7 34 Trioptic Code 7 34 Codablock F 7 35 Codablock F Message Length 7 35 Code 16K 7 35 Code 16K Message Length 7 36 Code 49 7 36 Code 49 Message Length 7 37 PDF417 7 37 PDF417 Message ...

Page 16: ...e Length 7 45 Korea Post 7 46 Korea Post Message Length 7 46 QR Code 7 47 QR Code Message Length 7 47 Data Matrix 7 48 Data Matrix Message Length 7 48 MaxiCode 7 49 MaxiCode Message Length 7 49 Aztec Code 7 50 Aztec Code Message Length 7 50 Aztec Runes 7 51 Chapter 8 Imaging Commands Single Use Basis 8 1 Command Syntax 8 1 Image Snap IMGSNP 8 2 IMGSNP Modifiers 8 2 Image Ship IMGSHP 8 6 IMGSHP Mod...

Page 17: ...Modulo 10 Check Character 9 9 OCR Modulo 36 Check Character 9 9 OCR User Defined Check Character 9 9 Weighting Options 9 10 OCR ISBN Application Example 9 12 OCR Template Codes 9 13 Chapter 10 Interface Keys Keyboard Function Relationships 10 1 Supported Interface Keys 10 3 Chapter 11 Utilities To Add a Test Code I D Prefix to All Symbologies 11 1 Show Decoder Revision 11 1 Show Engine Revision 11...

Page 18: ...ventions 12 1 Menu Command Syntax 12 1 Query Commands 12 2 Concatenation of Multiple Commands 12 2 Responses 12 3 Examples of Query Commands 12 3 Trigger Commands 12 4 Menu Commands 12 5 Programming the Interface 12 5 Basic System Operation 12 8 Output Selections 12 9 Prefix Suffix Selections 12 12 Data Formatter Selections 12 13 Symbologies 12 13 Imaging Default Commands 12 22 OCR Selections 12 2...

Page 19: ...SCII Conversion Chart Code Page 1252 A 4 Code Page Mapping of Printed Barcodes A 6 Chapter 15 Customer Support Technical Assistance 15 1 Online Technical Assistance 15 2 For Further Information 15 2 Product Service and Repair 15 2 Online Product Service and Repair Assistance 15 3 Limited Warranty 15 3 Appendix 16 Minimizing Bluetooth ISM Band Network Activ ity Auto Reconnect Mode 16 1 Maximum Link...

Page 20: ...xii ...

Page 21: ...containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the carton match your order Save the shipping container for later storage or shipping Image Scanner Models Models Description 4820SF0C1CBE Cordless Area Image Scanner Green aimer Spe cial Focus 4820SR0C1CBE Cordless Area Image Sca...

Page 22: ...h image scanner is shipped with a battery See Product Specifications beginning on page 13 1 Charging Information The battery is designed to charge while the image scanner is positioned in the cordless base unit Refer to 2020 LED Sequences and Meaning on page 3 4 for an interpretation of the Charge Status indicators Place the image scanner in the base that is connected to an appropriate power suppl...

Page 23: ...e end of its useful life the battery should be disposed of by a qualified recycler or hazardous materials handler Do not incinerate the battery or dispose of the battery with general waste materials You may send batteries to Hand Held Products postage paid The shipper is responsible for complying with all federal state and local laws and regulations related to the packing labeling manifesting and ...

Page 24: ...flat on a horizontal surface 2 Program the base for the USB interface by scanning the appropriate programming barcode See page 2 5 3 Verify the base operation by scanning a barcode from the Sample Symbols in the back of this manual For additional USB programming and technical information refer to the Hand Held Products USB Application Note available at www handheld com Connecting the Base with Key...

Page 25: ...bles are secured in the wireways in the bottom of the base and that the base sits flat on a horizontal surface 3 Turn the terminal computer power back on 4 Program the base for the keyboard wedge interface See Keyboard Wedge Connection on page 2 1 5 Verify the base operation by scanning a barcode from the Sample Symbols in the back of this manual ...

Page 26: ...ur type of terminal computer 3 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 4 Once the image scanner has been fully connected power up the computer Connecting the Base with RS 232 Wedge The 2020 uses TTL signal levels to wedge into an RS 232 serial network Use only 2020 serial wedge cables to prevent damage to the base R...

Page 27: ...r the base to work properly you must have the correct cable for your type of computer 4 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 5 Plug the other serial connector into the host connection and tighten the two screws 6 Plug the power supply to the base and plug into the AC source 7 Once the base has been fully connecte...

Page 28: ...etermine if your cordless system is set up correctly scan one of the sample barcodes in the back of this manual If the image scanner provides a single good read beep and the green LED lights the image scanner has successfully linked to the base If you receive a triple error beep and the red LED lights the image scanner has not linked to the base Refer to page 14 4 for troubleshooting information C...

Page 29: ... image scanner recognizes data acknowledgement ACK from the base unit If it cannot be determined that the data has been properly sent to the base the image scanner issues an error indication You must then check to see if the scanned data was received by the host system 3 Base sends data to host 1 Good Read 2 ACK from base ...

Page 30: ...de and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit To read single or multiple symbols on a page or on an object hold the image scanner at an appropriate distance from the target pull the trigger and center the aiming beam on the sym...

Page 31: ...effect Keyboard Wedge Connection If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard scan the barcode below Keyboard wedge is the default interface Note The following barcode also programs a carriage return CR suffix Laptop Direct Connect For most laptops scanning the Laptop Direct Connect barcode allows operation of the image scanner in...

Page 32: ...mits UPC EAN Code 128 and Interleaved 2 of 5 without any changes but converts all other symbologies to Code 39 The Wand Emulation Plug Play Code 39 Format barcode below sets the terminal ID to 61 The Wand Emulation Plug Play Same Code Format barcode sets the terminal ID to 64 These Plug Play barcodes also set the Transmission Rate to 25 inches per second Output Polarity to black high and Idle Stat...

Page 33: ...ms the following suffixes for each symbology Suffixes programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR 2 Interface Symbology Suffix EAN 8 0C EAN 13 16 UPC A 0D UPC E 0A Code 39 00 0A 0B Interleaved 2 of 5 00 0D 0B Code 128 00 0A 0B Code 128 00 18 0B IBM 4683 Port 5B Interface IBM 4683 ...

Page 34: ...USB Tabletop image scanner Note After scanning one of these codes you must power cycle the cash register Each barcode above also programs the following suffixes for each symbology Symbology Suffix EAN 8 0C EAN 13 16 UPC A 0D UPC E 0A Code 39 00 0A 0B Interleaved 2 of 5 00 0D 0B Code 128 00 18 0B IBM SurePos USB Handheld Scanner Interface IBM SurePos USB Tabletop Scanner Interface ...

Page 35: ...anning these codes adds a CR and LF along with selecting the terminal ID USB PC Keyboard 124 USB Macintosh Keyboard 125 USB PC Japanese Keyboard 134 USB HID Scan the following code to program the image scanner for USB HID barcode image scanners Scanning this code changes the terminal ID to 131 USB Keyboard PC USB Keyboard Mac USB Japanese Keyboard PC USB HID Barcode Image ...

Page 36: ... Products website www handheld com The driver will use the next available Com Port number Apple Macintosh computers recognize the image scanner as a USB CDC class device and automatically uses a class driver Scanning the code below changes the terminal ID to 130 Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode USB COM Port Emulation CTS RTS Emulation On CTS RTS...

Page 37: ...below then scan the numeric barcode s from the Programming Chart inside the back cover of this manual to program the image scanner for your terminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID barcode then 0 0 3 from the Programming Chart inside the back cover of this manual then Save If you make an error while scanning...

Page 38: ...3 3191 3192 3194 3196 3197 3471 3472 3476 3477 006 IBM 122 key 3191 3192 3471 3472 007 IBM 122 key 3196 3197 3476 3477 3486 3482 3488 008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Hand Held Image Scan ner 128 IBM SurePOS USB Tabletop Image Scanner 129 IBM Thinkpad 360 CSE 340 750 097 IBM Thinkpad 106 IBM Thinkpad 365 755CV 00...

Page 39: ... 1191 1192 1471 1472 1476 1477 1483 025 Telex 88 key Data Entry Keyboard 112 Telex 102 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1483 045 Telex 122 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1482 1483 046 USB COM Port Emulation 130 USB PC Keyboard 124 USB Mac Keyboard 125 USB Japanese Keyboard PC 134 USB HID POS 131 Wand Emulation Code 39 Format 061 Wand Emulation Same...

Page 40: ...o program the keyboard for your country As a general rule the following characters are supported but need special care for countries other than the United States United States Brazil Czech Republic Denmark Finland Sweden France Germany Austria Greece Hungary Belgium Canada French Israel Hebrew ...

Page 41: ...2020 4820 4820 i User s Guide 2 11 Keyboard Country continued Latin America Norway Poland Portugal Romania Russia SCS Slovakia Italy Netherlands Dutch Spain Sweden Switzerland German ...

Page 42: ...ry barcode below then scan the numeric barcode s for the appropriate country from the inside back cover then the Save barcode Keyboard Style This programs keyboard styles such as Caps Lock and Shift Lock Default Regular Regular is used when you normally have the Caps Lock key off Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock ...

Page 43: ...ance where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similarly to the regular Autocaps but uses the NumLock key to retrieve the current state of the Caps Lock Emulate External Keyboard should be scanned if you do not have an external keyboard IBM AT or equivalent Note After scanning the Emulate External Keyboard barcode you must power cycle your computer Keyboar...

Page 44: ...s should use the Windows mode Refer to Keyboard Function Relationships page 10 1 for CTRL ASCII Values Default Off Turbo Mode The image scanner sends characters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off Windows Mode Control ASCII Control ASCII Mode Off DOS Mode...

Page 45: ...s Guide 2 15 Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Page 46: ...2 Baud Rate Baud Rate sends the data from the image scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the image scanner Default 115 200 300 2400 600 1200 4800 38400 9600 19200 115 200 57 600 ...

Page 47: ... bits For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 8 Data...

Page 48: ...his manual then scanning Save The range is 0 to 300 seconds Default 0 seconds no time out always on RS 232 Handshaking RS 232 Handshaking allows control of data transmission from the image scanner using software commands from the host device CTS RTS operates in mode 2 When this feature is turned Off no data flow control is used When Data Flow Control is turned On the host device suspends transmiss...

Page 49: ...commended that each image scanner is assigned to its own group in host ACK mode The commands to which the image scanner responds are listed on page 2 21 The ESC is a 1B in hex A typical command string is y ESC x where y is the application work group number ESC x is the escape command and the comma is the terminator which is required Commands may be strung together to create custom response sequenc...

Page 50: ...2 20 2020 4820 4820 i User s Guide Host ACK Enable 1 Good Read 3 ACK Host to Base 4 ACK Base to Image Scanner 2 Base sends data to host Host ACK On Host ACK Off ...

Page 51: ...me when multiple blinks ESC 2 Illuminate green LED for two seconds followed by at least 500 mSecs dark time when multiple blinks ESC 3 Illuminate green LED for five seconds followed by at least 500 mSecs dark time when multiple blinks ESC 4 One beep at low pitch tone ESC 5 One beep at medium pitch tone ESC 6 One beep at high pitch tone ESC 7 Indicate as successful decode and communication to host ...

Page 52: ... page 2 2 for further information In Wand Emulation mode the image scanner decodes the barcode then sends data in the same format as a wand scanner The Code 39 Format converts all symbologies to Code 39 The Same Code Format transmits UPC EAN Code 128 and Interleaved 2 of 5 without any changes but converts all other symbologies to Code 39 2D symbologies are converted to Code 128 The Code 39 Format ...

Page 53: ...ll Checksum When this option is turned on a computed check character is added at the end of the entire message The check character is the character which when Exclusive OR d with every preceding character of the message yields a result of 0x00 00H Default Off 5ms 500ms 50ms 150ms Wand Emulation Overall Checksum On Wand Emulation Overall Checksum Off ...

Page 54: ...e is limited by the terminal s ability to receive data without dropping characters Default 25 inches second Wand Emulation Polarity The Polarity can be sent as standard with black bars high or reversed with white spaces high Default Black High 10 80 25 40 120 150 200 Black High White High ...

Page 55: ...e describes the state of the image scanner when no data is being transmitted When in Wand Emulation mode you must set the image scanner s idle state to match the idle state for the device to which the image scanner is connected Default Idle High Idle High Idle Low ...

Page 56: ...2 26 2020 4820 4820 i User s Guide ...

Page 57: ...e point applications the radio operates using a license free ISM band which sends relatively small data packets at a fast data rate over a radio signal with randomly changing frequencies makes the cordless system highly responsive to a wide variety of data collection applications and resistant to noisy RF environments Bluetooth Class 2 power level provides a communication range of 33 feet 10m betw...

Page 58: ... is out of range and you scan a barcode the image scanner issues a triple beep indicating no communication with the base In addition your image scanner and base can sound an alarm if programmed to emit an alarm Refer to Out of Range Alarm on page 3 22 Image Scanner Is Moved Back Into Range The image scanner re links if the image scanner or the base have been reset or the image scanner comes back i...

Page 59: ...te If you attach the 4820 system to a host with a 12V power source the 12V host is dominant the system pulls power from the host and not the 9V power supply For example if you have a host system with a 12 volt available to the base it will supersede the 9V power supply The 9V supply is not needed for 12V host applications and only serves as a backup if the system goes down Scan the appropriate bar...

Page 60: ... that indicates the status of the unit and verifies its communication with the host system and a green LED that indicates image scanner battery charge condition Note Charging only occurs with external power applied to the 2020 or 12 volt host power LED Indication Beeper Indication Cause Normal Operation Red Flash None Battery low Green Flash 1 beep Successful communication or linking Red blinking ...

Page 61: ...the base scan the Unlink Image Scanner barcode below Single Image Scanner Operation There are two link modes to accommodate different applications Locked Link Mode and Open Link Mode Scan the appropriate barcodes included in the Open Link and Locked Link Mode explanations that follow to switch from one mode to another Default Locked Link Mode System Condition System Status Indicator Red LED Power ...

Page 62: ...and image scanner are not linked By placing an image scanner into the base they establish a link Placing a different image scanner into the base establishes a new link and the old image scanner is unlinked Each time an image scanner is placed into the base it becomes the linked image scanner the old image scanner is unlinked Override Locked Image Scanner If you need to replace a broken or lost ima...

Page 63: ... to one base You cannot join an eighth image scanner until you unlink one of the 7 image scanners or take an image scanner out of range To put the image scanner in multiple image scanner mode scan the barcode below Once you scan this barcode the image scanner is unlinked from the base and must be placed into the base to re link Multiple Image Scanner ...

Page 64: ...scanner linked to a base and they all have the default names the first image scanner linked to the base receives commands You can change the name of an image scanner using a serial command refer to Image Scanner Name on page 12 8 or using a barcode command To change the name serially unlink all except one of the image scanners from the base Send 4820 BT_NAMname or 4820i BT_NAMname where name is th...

Page 65: ...end serial commands to the base One way to do this is to scan the barcode below and scan a number for the image scanner name For example if you had 7 image scanners to one base scan the barcode below with the first image scanner scan the 1 barcode on the Programming Chart inside the back cover of this manual and scan Save Then scan the Reset barcode and wait for the scanner to re link to the base ...

Page 66: ...que work group and may program each image scanner independently For example you might want to have multiple work groups in a retail warehouse application where you need to have different data appended to barcodes used in the warehouse area versus the retail area You could assign all of the image scanners in the retail area to one work group and those in the warehouse to another Consequently any de...

Page 67: ... programming selection allows you to assign an image scanner to a work group by scanning the barcode below You may then program the settings e g beeper volume prefix suffix data formatter that your application requires Group 0 Group 1 Group 2 Group 4 Group 6 Group 3 Group 5 ...

Page 68: ...12 5 list the factory default settings for each of the commands indicated by an asterisk on the programming pages Note Scanning this barcode also causes both the image scanner and the base to perform a reset and become unlinked The image scanner must be placed in its base to re establish the link before any setup codes are entered Refer to Image Scanner Modes on page 3 5 for additional information...

Page 69: ...ll not reconnect to the Bluetooth device when it is back in range If you want to re link to the 2020 base refer to Override Locked Image Scanner on page 3 6 or Resetting the Standard Product Default Settings Current Application Work Group on page 3 12 Note The multiple work groups option is not available when you are using the image scanner with Bluetooth devices other than the 2020 base PDA Mobil...

Page 70: ...3 14 2020 4820 4820 i User s Guide 2 Tap the Start flag at the top left of the Today screen 3 Select Settings at the bottom of the menu ...

Page 71: ...de 3 15 4 Tap the Connections tab at the bottom of the screen and then tap the Radio Manager icon 5 Enable one of the Bluetooth modes e g Bluetooth only or 80211b Bluetooth The screen below shows that only the GSM radio is active ...

Page 72: ... The status changes to Success 7 Tap OK in the top right of the screen and tap X on the upper right corner to return to the Today screen The Bluetooth icon displays in the bottom right part of the screen 8 Tap the Bluetooth icon in the bottom right part of the screen ...

Page 73: ...eatures Bluetooth Devices Note If you have already used Bluetooth and changed any of the default settings you may want to first select My Bluetooth device and ensure that it is connectable and the Bluetooth com port is enabled 10 Tap Tools Device Discovery ...

Page 74: ... default radio button selection of Any Bluetooth device and select Next The Mobility Systems device searches for other Bluetooth devices If the 4820i is in BT Connection PDA Mobility Systems Mode see BT Connection PDA Mobility Systems Device on page 3 13 it will appear in the device discovery window ...

Page 75: ...2020 4820 4820 i User s Guide 3 19 13 Select the 4820i by checking the box and select Next and Finish 14 Select Next and Finish 15 Select the X to return to the desktop ...

Page 76: ...t time you connect to your PDA or PC The PIN code must be between 1 and 16 characters To change the PIN scan the barcode below and then scan the appropriate numeric barcodes from the Programming Chart inside the back cover of this manual Scan Save to save your selection When authentication is enabled on the Mobility Systems device you must enter the PIN of the image scanner 1 Select Advanced Featu...

Page 77: ...er a passkey for the Mobility Systems device The PIN entered for the Mobility Systems device must match the one configured on the image scanner Once you select the 4820i device in Step 13 page page 3 19 the following screen appears 1 In the Bluetooth Passkey box enter the image scanner s PIN code The same Bluetooth passkey PIN code is required for each device 2 Tap Reply ...

Page 78: ...then set the time out duration from 0 3000 seconds by scanning digits on the Programming Chart inside the back cover then scanning Save Default 0 sec no alarm Note If you are out of range when you scan a barcode you will receive an error beep even if you do not have the alarm set You receive the error beep since the data could not be communicated to the base or the host Alarm Sound Type If you hav...

Page 79: ...d transmitted once the image scanner is back in range Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system the transmission of those scans is too fast for the application to process To program a transmit delay between accumulated scans scan one of the following delays Note In most cases a short 250 ms milliseconds delay is ideal however longer delays may be progra...

Page 80: ...3 24 2020 4820 4820 i User s Guide ...

Page 81: ...ood read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the image scanner emits on a good read Default Medium Beeper Good Read On Beeper Good Read Off High Medium Off Low ...

Page 82: ...d read Default Medium Beeper Duration Good Read The beeper duration codes modify the length of the beep the image scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On Low 1600 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep LED Good Read On LED Good Read Off ...

Page 83: ...scan the barcode below and then scan a digit 1 9 barcode and the Save barcode on the Programming Chart inside the back cover of this manual Default One Good Read Delay This sets the minimum amount of time before the image scanner can read another barcode Default 0 ms No Delay User Specified Good Read Delay If you want to set your own length for the good read delay scan the barcode below then set t...

Page 84: ... Use this selection to set a time out in milliseconds of the image scanner s trigger when using serial commands to trigger the image scanner Once the image scanner has timed out you can activate the image scanner either by pressing the trigger or using a serial trigger command After scanning the Read Time Out barcode set the time out duration from 0 300 000 milliseconds by scanning digits on the P...

Page 85: ...r time out timer is reset If the image scanner is placed in the 2020 cradle and the battery is in the process of being charged the image scanner will not go into power down mode Note When the image scanner is in power down mode pull the trigger to power the unit back up There will be a set of power up beeps and a delay of up to a few seconds for the radio to join The image scanner will then be rea...

Page 86: ... scanner automatically adjusts the illumination LEDs to the lowest light level possible to maintain a good lock on the Scan Stand symbol When a symbol is presented the image scanner s light levels adjust to the saved setting see LED Power Level on page 4 10 This mode requires at least 50 lux of ambient light to operate correctly Scan Stand Symbol When a unit is in Scan Stand mode the LEDs shine at...

Page 87: ...o read the code If the light level in the room is not high enough Presentation Mode may not work properly Presentation LED Behavior after Decode When an image scanner is in presentation mode the LEDs remain on and continue scanning for a short time after a barcode is decoded If you wish to turn the LEDs off immediately after a barcode is decoded scan the LEDs Off barcode below Default LEDs On Pres...

Page 88: ...If the image scanner s trigger is pulled when using a hands free mode the image scanner changes to manual trigger mode You can set the time the image scanner should remain in manual trigger mode by setting the Hands Free Time Out Once the time out value is reached if there have been no further trigger pulls the image scanner reverts to the original hands free mode Scan the Hands Free Time Out barc...

Page 89: ...ed Reread Delay If you want to set your own length for the reread delay scan the barcode below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Short 500 ms Medium 750 ms Long 1000 ms Extra Long 2000 ms Extra Long 2000 ms User Specified Reread Delay ...

Page 90: ...evel Note If you scan the Off barcode both the aimer and illumination lights turn off making it impossible to scan barcodes in low light To turn the LED Power Level back on move to a brightly lit area and scan either the Low or the High barcode below Illumination Lights If you want the illumination lights on while reading a barcode scan the Lights On barcode below However if you want to turn just ...

Page 91: ...n t turn on until the delay time is over User Specified Aimer Delay If you want to set your own length for the duration of the delay scan the barcode below then set the time out by scanning digits 0 4 000 ms from the Programming Chart inside the back cover of this manual then scan Save Aimer Mode This feature allows you to turn the aimer on and off When the Interlaced barcode is scanned the aimer ...

Page 92: ...r Delay and Centering features the image scanner can emulate the operation of older systems such as linear laser barcode image scanners In the example below the gray area is the full image scanner field of view and the white area is the centering window Barcode 1 will not be read while Barcode 2 will be The default centering window is a 128x96 pixel area in the center of the image scanner s field ...

Page 93: ...ng the Top Bottom Left or Right barcodes Scan Centering On then scan one of the following barcodes to change the top bottom left or right of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Top and Left 60 for Bottom and Right Left of Centering Window Top of Centering Window Rig...

Page 94: ...e both bar code symbologies appear on the same label but the lower priority symbology cannot be disabled For example you may be using the imager in a retail setting to read UPC symbols but have occasional need to read a code on a drivers license Since some licenses have a Code 39 symbol as well as the PDF417 symbol you can use Preferred Symbology to specify that the PDF417 symbol be read instead o...

Page 95: ... Scan Save to save your selection Default None Low Priority Symbology To specify the low priority symbology scan the Low Priority Symbology bar code below On the Symbology Chart on page A 1 find the symbology you want to set as low priority Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside back cover If you want to set additional low priority ...

Page 96: ... imager will search for a high priority bar code after a low priority bar code has been encountered Scan the bar code below then set the delay from 1 3 000 milliseconds by scanning digits from the inside back cover then scanning Save Default 500 ms Preferred Symbology Default Scan the bar code below to set all Preferred Symbology entries to their default values Preferred Symbology Time out Preferr...

Page 97: ...your application requires Use the Alphanumeric symbols inside back cover to read these options To Add an Output Sequence 1 Scan the Enter Sequence symbol see Require Output Sequence page 4 19 2 Code I D On the Symbology Chart on page A 1 find the symbology to which you want to apply the output sequence format Locate the Hex value for that symbol ogy and scan the 2 digit hex value from the Programm...

Page 98: ...ou would set up the sequence editor with the following command line SEQBLK62999941FF6A999942FF69999943FF The breakdown of the command line is shown below SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39 9999 all lengths 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 9999 ...

Page 99: ...th 11 plus CR suffix 1 12 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 0013 B Code 128 sample length 12 plus CR suffix 1 13 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 0012 C Code 93 sample length 11 plus CR suffix 1 12 43 start character match for Code 93 43h C F...

Page 100: ...old the trigger aiming the image scanner at a series of symbols it reads unique symbols once beeping if turned on for each read The image scanner attempts to find and decode new symbols as long as the trigger is pulled When this programming selection is turned Off the image scanner will only read the symbol closest to the aiming beam No Read With No Read turned On the image scanner notifies you if...

Page 101: ...ormance For consistently light printing a print weight of 2 may help After scanning the Set Print Weight barcode set the print weight from 1 7 by scanning digits from the inside back cover then scanning Save Default 4 Video Reverse Video Reverse is used to allow the image scanner to read barcodes that are inverted The Off barcode below is an example of this type of barcode If additional menuing is...

Page 102: ...de down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the image scanner Default Upright Upright Rotate Code Clockwise 90 Upside Down Rotate Code Counterclockwise 90 Upright Rotate Code Clockwise 90 Rotate Image Scanner Counterclockwise Upside Down Rotate Code Counterclockwise 90 Rotate Image Scanner ...

Page 103: ...ans the FIPS security is working and data transmissions between the scanner and base are encrypted It also means the FIPS software has been loaded in the scanner and base successfully Error Indicator Red LED If it illuminates with every trigger pull it means the FIPS security is not working and transmissions between the scanner and base will not be encrypted It means the FIPS software was installe...

Page 104: ...are has been installed in both the scanner and base successfully Error Indicator Security Warning Double Beep A short double beep and the red LED flashing on the base with every scan means the last transmission between the scanner and base was not encrypted It means the FIPS software has been installed in the base but not in the scanner The following barcode can be scanned to display the scanner a...

Page 105: ...f you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the Code Page Mapping of Printed Barcodes on page A 6 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in ...

Page 106: ... C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leading backslash and then to create the backslash itself Step 8 Scan Save to exit and save or scan Discard to exit without saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for UPC only Step 1 Scan Add Suffix Step ...

Page 107: ...2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Chart beginning on page A 1 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to all Symbologies Sca...

Page 108: ...age scanner transmits the function code to the terminal Charts of these function codes are provided in Supported Interface Keys starting on page 10 3 When the image scanner is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Add Prefix Clear One Prefix Clear All Prefixes Add Suffix Clear One Suffix Clear All Suffixes Enable Disable ...

Page 109: ... 0 495 ms Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data Scan the Intercharacter Delay barcode below then scan the number of milliseconds and the SAVE barcode using the Programming Chart inside the back cover of this manual To remove this delay scan the Intercharacter Delay barcode then set the number ...

Page 110: ...ge A 6 To remove this delay scan the Delay Length barcode and set the number of steps to 0 Scan the SAVE barcode using the Programming Chart inside the back cover of this manual Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string Scan the Interfunction Delay barcode below then scan the number of milliseco...

Page 111: ...low then scan the number of milliseconds and the SAVE barcode using the Programming Chart inside the back cover of this manual To remove this delay scan the Intermessage Delay barcode then set the number of steps to 0 Scan the SAVE barcode using the Programming Chart inside the back cover of this manual 2nd Scan Transmission 1st Scan Transmission Intermessage Delay Intermessage Delay ...

Page 112: ...5 8 2020 4820 4820 i User s Guide ...

Page 113: ... ID Actual Length 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code on page 6 4 To Add a Data Format Step 1 Scan the Enter Data Format symbol page 6 4 ...

Page 114: ...de the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the alternate format you are clearing Scan the Terminal Type and Code I D see Supported Terminals on page 2 8 and the barcode data length for the specific data format that you want to delete All other formats remain unaffected Save from the Programming Chart inside the back cover of this manual This...

Page 115: ... page A 6 F9 Search back for xx character from current cursor position leaving cursor pointing to xx character Syntax F9xx xx stands for the hex value for an ASCII code see Code Page Mapping of Printed Barcodes on page A 6 E6 Search ahead for the first non xx character from the current cursor posi tion leaving cursor pointing to non xx character Syntax E6xx xx stands for the hex value for an ASCII...

Page 116: ...or If characters are not equal no format match Syntax FExx xx stands for the hex value for an ASCII code see Code Page Mapping of Printed Barcodes on page A 6 EC Check to make sure there is an ASCII number at the current cursor position If character is not numeric format is aborted Syntax EC ED Check to make sure there is a non numeric ASCII character at the current cursor position If character is...

Page 117: ...you single shot capability to scan one barcode using a different data format than your primary format When data formats are programmed see page 6 1 you must input whether you are programming the primary format or an alternate format numbered 1 2 or 3 An alternate format is initiated by scanning one of the 3 alternate format barcodes below The image scanner will scan the next barcode formatting the...

Page 118: ...6 6 2020 4820 4820 i User s Guide ...

Page 119: ...therlands Post British Post Korea Post Canadian Post Matrix 2 of 5 China Post MaxiCode Codabar MicroPDF417 Codablock F MSI Code 11 PDF417 Code 128 Planet Code Code 16K Plessey Code Code 39 PosiCode A and B Code 49 Postnet Code 93 QR Code Data Matrix Straight 2 of 5 IATA EAN JAN 13 Straight 2 of 5 Industrial EAN JAN 8 TCIF Linked Code 39 TLC39 EAN UCC Composite Codes Telepen GS1 DataBar Omnidirecti...

Page 120: ...y wish to set the same value for minimum and maximum length to force the image scanner to read fixed length barcode data This helps reduce the chances of a misread EXAMPLE Decode only those barcodes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those barcodes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum m...

Page 121: ...acters are created using different modulos You can program the image scanner to read only Codabar barcodes with Modulo 16 check characters Default No Check Character No Check Character indicates that the image scanner reads and transmits barcode data with or without a check character When Check Character is set to Validate and Transmit the image scanner will only read Codabar barcodes printed with...

Page 122: ... looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Default On Select Require to prevent the image scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Charac...

Page 123: ... below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Code 39 Default All Code 39 Settings Code 39 Minimum Message Length Maximum Message Length On Off ...

Page 124: ...ith or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 barcodes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the image scanner only reads Code 39 barcodes printed with a check character and will transmit this character at the end of...

Page 125: ...arcodes together before transmitting them to the host computer When this function is enabled the image scanner stores those Code 39 barcodes that start with a space excluding the start and stop symbols and does not immediately transmit the data The image scanner stores the data in the order in which the barcodes are read deleting the first space from each The image scanner transmits the appended d...

Page 126: ...For example V will be decoded as the ASCII character SYN and C will be decoded as the ASCII character Default Off NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X ...

Page 127: ...nned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see Code Page Mapping of Printed Barcodes on page A 6 and scan the value and the Save barcode from the Programming Chart on the inside the back cover of this manual The data characters should then appear...

Page 128: ...n Check Digit is set to Validate and Transmit the image scanner only reads Interleaved 2 of 5 barcodes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths ...

Page 129: ...de 93 Code 93 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 130: ...e host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see Code Page Mapping of Printed Barcodes on page A 6 and scan the value and the Save barcode from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Straight 2 of 5 Industrial three bar start stop Default Al...

Page 131: ...e message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Straight 2 of 5 IATA two bar start stop Default All Straight 2 of 5 IATA Settings Straight 2 of 5 IATA Minimum Message Length Maximum Message Length On Off ...

Page 132: ...elow to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 Minimum Message Length Maximum Message Length On Off ...

Page 133: ...odes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 Minimum Message Length Maximum Message Length On Off ...

Page 134: ... Check Digits Code 11 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 128 Default All Code 128 Settings One Check Digit Two Check Digits Minimum Message Length Maximum Message Length ...

Page 135: ...ecommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neighboring symbols and 4 the standard layout for barcodes on a blood product label Use the barcodes below to turn concatenation on or off Default Off Code 128 Message Length Scan the barcodes below to change the message length Refer to Message Le...

Page 136: ... page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see Code Page Mapping of Printed Barcodes on page A 6 and scan the value and the Save barcode from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Telepen Default All...

Page 137: ... start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings Original Telepe...

Page 138: ...er the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On On Off On Off Off On ...

Page 139: ...ge scanner will only read UPC A barcodes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 7 21 Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not...

Page 140: ...isable UPC A and EAN 13 with Extended Coupon Code Default On UPC E0 Default All UPC E Settings UPC E0 Most U P C barcodes lead with the 0 number system For these codes use the UPC E0 selection If you need to read codes that lead with the 1 number system use UPC E1 page 7 25 Default On On Off UPC E0 On UPC E0 Off ...

Page 141: ... Required When Addenda Required is set to on the image scanner will only read UPC E barcodes that have addenda Default Not Required UPC E0 Addenda Separator When this feature is on there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On Off On Not Required Required Off On ...

Page 142: ... numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda Off On Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 143: ... barcodes lead with the 0 number system For these codes use UPC E0 page 7 22 If you need to read codes that lead with the 1 number system use the UPC E1 selection Default Off EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 UPC E1 On UPC E1 Off On Off ...

Page 144: ... 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Addenda Required is set to on the image scanner will only read EAN JAN 13 barcodes that have addenda Default Not Required Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Page 145: ...denda When turned off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 7 22 ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings Off On Off On ...

Page 146: ... check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 147: ...ill only read EAN JAN 8 barcodes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is on there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On MSI Default All MSI Settings MSI Not Required Required Off On On Off ...

Page 148: ...haracter at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read MSI barcodes printed with the specified type check character but will not transmit the check character with the scanned data MSI Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum ...

Page 149: ...ge length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off Minimum Message Length Maximum Message Length On Off ...

Page 150: ...020 4820 4820 i User s Guide GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings GS1 DataBar Expanded On Off On Off ...

Page 151: ...es below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 PosiCode Default All PosiCode Settings PosiCode A and B Minimum Message Length Maximum Message Length On Off ...

Page 152: ... page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Trioptic Code Note If you are going to scan Code 32 Pharmaceutical codes page 7 8 Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media A and B On No Limited A and B and Limited A On Limited B Off A and B and Limited B On Limited A Off Minimum Message Length Maxi...

Page 153: ...Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Code 16K Default All Code 16K Settings On Off Minimum Message Length Maximum Message Length ...

Page 154: ...s below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160 Code 49 Default All Code 49 Settings Code 49 On Off Minimum Message Length Maximum Message Length On Off ...

Page 155: ...es below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 81 PDF417 Default All PDF417 Settings PDF417 Minimum Message Length Maximum Message Length Off On ...

Page 156: ...o change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MicroPDF417 Default All MicroPDF417 Settings MicroPDF417 Maximum Message Length Minimum Message Length Off On ...

Page 157: ...e combined with a unique 2D composite component to form a new class called EAN UCC Composite symbology EAN UCC Composite symbologies allow for the co existence of symbologies already in use UPC EAN Version Scan the UPC EAN Version On barcode to decode EAN UCC Composite symbols that have a UPC or EAN linear component This does not affect EAN UCC Composite symbols with a UCC EAN 128 or GS1 linear co...

Page 158: ...nd Composite symbol EAN UCC data carriers include UPC A and UPC E EAN 13 and EAN 8 ITF 14 UCC EAN 128 and EAN UCC GS1 and Composites Data from 2D symbols such as Aztec Code Data Matrix or QR Code which encode a leading FNC1 also invoke EAN UCC emulation If UCC EAN 128 Emulation is selected the AIM Symbology Identifier is reported as C1 If GS1 Emulation is selected the AIM Symbology Identifier is r...

Page 159: ... Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Postal Codes Note For best performance when reading a postal symbology all other postal symbologies should be turned off The following postal codes can only be read by a 2D image scanner 4 CB 4 State Customer Barcode ID tag UPU 4 State ...

Page 160: ... digit should be transmitted at the end of the scanned data Planet Code Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Off On Don t Transmit Check Digit Transmit Check Digit Off On Don t Transmit Check Digit Transmit Check Digit ...

Page 161: ...anadian Post Kix Netherlands Post Note Kix code can misread when scanned sideways or upside down Use Working Orientation page 4 22 if your Kix codes will not usually be presented upright to the image scanner Australian Post Off On Off On Off On Off On ...

Page 162: ...e symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Japanese Post Numeric N Table Bar Output Alphanumeric C Table Off On ...

Page 163: ...ina Post China Post Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 164: ...rea Post Korea Post Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 165: ... both QR Code and Micro QR Code QR Code Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 3500 Minimum Default 1 Maximum Default 3500 Off On Maximum Message Length Minimum Message Length ...

Page 166: ... Matrix Data Matrix Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 1500 Minimum Default 1 Maximum Default 1500 Off On Maximum Message Length Minimum Message Length ...

Page 167: ...iCode MaxiCode Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Off On Maximum Message Length Minimum Message Length ...

Page 168: ...c Code Aztec Code Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 3750 Minimum Default 1 Maximum Default 3750 Off On Maximum Message Length Minimum Message Length ...

Page 169: ...User s Guide 7 51 Aztec Runes Select Enable Runes if you are scanning Aztec runes which are the smallest type of Aztec Code symbol with the ability to encode a very short license plate message Disable Runes Enable Runes ...

Page 170: ...7 52 2020 4820 4820 i User s Guide ...

Page 171: ... Image Snap command such as setting the Imaging Style to 1P and the Wait for Trigger to 1T you would enter IMGSNP1P1T Note After processing an image capture command IMGSNP or IMGBOX you must follow it with an IMGSHP command if you want to see it on your terminal To add a command to a sequence each new command is separated with a semicolon For example to add the Image Ship command to the above sequ...

Page 172: ...iers P Imaging Style This sets the Image Snap style 0P Decoding Style This processing allows a few frames to be taken until the exposure parameters are met The last frame is then available for further use 1P Photo Style default This mimics a simple digital camera and results in a visually optimized image 2P Manual Style This is an advanced style that should only be used by an experienced user It a...

Page 173: ... E Exposure Exposure is used in Manual Style only 2P and allows you to set the exposure time This is similar to setting a shutter speed on a camera The exposure time determines how long the imager takes to record an image On a bright day exposure times can be very short because plenty of light is available to help record an image At nighttime exposure time can increase dramatically due to the near...

Page 174: ... exposure times and brighter images but if the setting is too high the image may be overexposed Target White Value is only available when using Photo Style 1P Default 125 nW Range 0 255 D Delta for Acceptance This sets the allowable range for the white value setting see W Target White Value Delta is only available when using Photo Style 1P Default 25 nD Range 0 255 U Update Tries This sets the max...

Page 175: ...elow the target white value and 25 of the pixels are above the target white value Altering this setting from the default is not recommended under normal circumstances To alter grayscale values W Target White Value should be used Default 50 n Range 1 99 Example of Target Set Point Percentage at 97 Example of Target Set Point Percentage at 40 Example of Target Set Point Percentage at 50 ...

Page 176: ...emory Modifiers always begin with a number and end with a letter case insensitive Any number of modifiers may be appended to the IMGSHP command For example you can use the following command to snap and ship a bitmap image with gamma correction and document image filtering IMGSNP IMGSHP8F75K26U IMGSHP Modifiers A Infinity Filter Enhances pictures taken from very long distances greater than 10 feet ...

Page 177: ...An edge sharpen filter cleans up the edges of an image making it look cleaner and sharper While edge sharpening does make the image look cleaner it also removes some fine detail from the original image The strength of the edge sharpen filter can be entered from 1 to 24 Entering a 23E gives the sharpest edges but also increases noise in the image 0E Don t sharpen image default 14E Apply edge sharpe...

Page 178: ...to lower right 1 pixel bit 0 padded end of line 5F Uncompressed grayscale upper left to lower right bitmap format 6F JPEG image default 8F BMP format lower right to upper left uncompressed H Histogram Stretch Increases the contrast of the transmitted image Not available with some image formats 0H No stretch default 1H Histogram stretch Example of Histogram Stretch at 0H Example of Histogram Stretc...

Page 179: ...d the Y axis flips picture left to right IF Noise Reduction Used to reduce the salt and pepper noise in an image 0if No salt and pepper noise reduction default 1if Salt and pepper noise reduction Example of image with Invert Image set to 1ix Example of image not inverted Example of image with Invert Image set to 1iy Example of Noise Reduction On 1if Example of Noise Reduction Off 0if ...

Page 180: ...is selected Higher numbers result in higher quality but larger files Smaller numbers result in greater amounts of lossy compression faster transmission times lower quality but smaller files Default 50 nJ Image is compressed as much as possible while preserving quality factor of n n 0 100 0J worst quality smallest file 100J best quality largest file Example of Image Rotate set to 0ir Example of Ima...

Page 181: ...te Image Cropping should not be used with IMGSHP Modifiers see page 8 6 Ships a window of the image by specifying the left right top and bottom pixel coordinates Device columns are numbered 0 through 1279 and device rows are numbered 0 through 959 nL The left edge of the shipped image corresponds to column n of the image in memory Range 000 640 Default 0 nR The right edge of the shipped image corr...

Page 182: ...e remaining center pixels Range 0 238 Default 0 or full image P Protocol Used for shipping an image Protocol covers two features of the image data being sent to the host It addresses the protocol used to send the data Hmodem which is an Xmodem 1K variant that has additional header information and the format of the image data that is sent 0P None raw data 2P None default for USB 3P Hmodem compresse...

Page 183: ... image becomes unusable 1S ship every pixel default 2S ship every 2nd pixel both horizontally and vertically 3S ship every 3rd pixel both horizontally and vertically U Document Image Filter Allows you to input parameters to sharpen the edges and smooth the area between the edges of text in an image This filter should be used with gamma correction see page 8 11 with the imager in a stand and the im...

Page 184: ...ter for typical document image nU Apply document image filter using grayscale threshold n Use lower numbers when the image contrast is lower 1U will have a similar effect to setting E Edge Sharpen page 8 7 to 22e Range 0 255 V Blur Image Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image 0V Don t blur default 1V Blur Example of Document...

Page 185: ...mage Size Compatibility If you prefer that an image ship returns images at the sensor s native resolution 752x480 pixels for the 5X00 engine 640x480 pixels for the 4X00 engine scan the Native Resolution code If you have an image scanner with a 4X00 image engine and have designed applications that expect an image ship to return exactly 640x480 pixels scan the Force VGA Resolution barcode Refer to S...

Page 186: ...ssible IMGBOX command The following IMGBOX example was executed and viewed using QuickView software This software is available at www handheld com Click on Software Downloads Select 4820 from the Products list then select QuickView Software Utility Below is an example of a signature capture application In this example the aimer is centered over the signature capture area and the trigger is pressed...

Page 187: ...f Signature Capture Area page 8 18 and W Width of Signature Capture Area page 8 19 IMGBOX Modifiers A Output Image Width This option is used to size the image horizontally If using this option set the resolution R to zero B Output Image Height This option is used to size the image vertically If using this option set the resolution R to zero D Pixel Depth This indicates the number of bits per pixel...

Page 188: ...of the area to be captured is 3 8 inch resulting in a value of H 375 0 01 37 5 K Gamma Correction Gamma measures the brightness of midtone values produced by the image You can brighten or darken an image using gamma correction A higher gamma correction yields an overall brighter image The lower the setting the darker the image The optimal setting for text images is 50K 0K Gamma correction off defa...

Page 189: ...imensions used in IMGBOX are measured as multiples of the minimum element size of the barcode The barcode aspect ratio allows you to set the ratio of the barcode height to the narrow element width In the example the narrow element width is 010 inches and the barcode height is 0 400 inches resulting in a value of S 0 4 0 01 40 W Width of Signature Capture Area The width of the signature capture are...

Page 190: ...hat Quick View see Quick View on page 11 6 and other applications are able to perform imaging functions as if they were talking directly to an image scanner To accomplish this the image scanner uses a menu command called RF_DID RF Default Imaging Device RF_DID is the name of the image scanner BT_NAM that is to receive imaging commands The default for RF_DID is indicating that imaging commands are ...

Page 191: ...r SEMI fonts See OCR Templates on page 9 3 if you want to create a custom template or character string that defines the length and content of OCR strings that will be read with your image scanner Note Setting the template and check character options are essential for OCR reading OCR Fonts Default All OCR Settings turns off all OCR capability in the image scanner so the image scanner will be able t...

Page 192: ...template can be scanned see Creating an OCR Template page 9 4 U S Currency Font U S Currency On allows you to scan characters in the font used on U S currency The default setting allows you to scan any eight digit combination If you have created an OCR template character combinations that fit the template can be scanned see Creating an OCR Template page 9 4 MICR E13 B Font MICR E13 B On allows you...

Page 193: ... will be retained in memory OCR Templates You can create a custom template or character string that defines the length and content of OCR strings that will be read with your image scanner There are several choices when creating a custom template for your application You can create a template for a single format you can string together several formats and you can create a template for a user define...

Page 194: ...mming Chart after the Sample Codes in the back of this manual to scan the characters for your template Example You need to read any combination of eight digits The template would be a represents any alphanumeric character digit or letter c represents a check character position d represents any digit e represents any available OCR character g represents character from user defined variable g h repr...

Page 195: ...le You need to read three digits three specific characters ABC three digits The template would be ddd414243ddd To create this template you would enable the OCR A font Scan the Enter OCR Template symbol page 9 13 Scan the d from the OCR Programming Chart in the back of this manual three times Then scan 414243 from the inside back cover the hex characters for A B and C and scan the d three more time...

Page 196: ...nging Together Multiple Formats Creating Or Statements You may want to program the image scanner to accept many OCR formats To do this you would string together each format with a t This tells the image scanner to read optical characters that match any one of the formats in the template Example You need to read any combination of eight digits or a combination of four digits two uppercase letters a...

Page 197: ...e Enter User Defined Variable g symbol page 9 13 Scan 414243 from the Programming Chart the hex characters for A B and C Scan Save OCR Template page 9 14 This will let you read either A or B or C in any position where you place the g For example you could create the following template ddddddggg This template would then let you read data that began with six digits and had an A B or C trailing So yo...

Page 198: ...check character uses e g modulo 10 and modulo 36 Scan the OCR Modulo 10 or OCR Modulo 36 Check Character barcode to specify the type of check character used in the OCR strings you re scanning The image scanner will then only read OCR character strings with a valid check character The image scanner transmits the OCR data without the check character data You must specify the location of the check ch...

Page 199: ...its proper order The number of characters you enter determines the modulo value for the calculation By default the check character computation is unweighted but the image scanner also supports two weighted modulo 10 checking schemes Example To program a modulo 11 check character you would enter the following 11 characters in order 0123456789X Also enter the OCR template dddddddc Enable the OCR A f...

Page 200: ...fter you enter all the desired hex values scan the Save barcode on the inside back cover of this manual Weighting Options By default the check character computation is unweighted It is possible to use one of two weighted modulo 10 schemes Weighting is often used to detect if two neighboring characters are transposed a common error when an operator keys in data 3 1 3 1 Weighted Modulo 10 Check Char...

Page 201: ...he multiplication is greater than 9 add both digits to the running sum This is often referred to as the LUHN formula One common application of the LUHN formula is validate credit card numbers This is the modulo 10 checking scheme used in MSI Code and in Code 32 Pharmaceutical PARAF To apply this weighting scheme set the OCR check character to 0123456789x2x1 or scan the following symbol Example Sca...

Page 202: ... which the image scanner is aimed 1 Scan the OCR B On barcode on page 9 2 2 Program the user defined variable g to comprise the ten digits plus the dash 0123456789 3 In Japan it is common for two fields to follow the ISBN number the three digit price field and the four digit price field The first field typically starts with a C uppercase c followed by four digits The second field typically starts ...

Page 203: ...commands can be combined into a single serial programming command OCRENA2 TMP ISBNggggggggggggctCdddd hdddEtCdddd hddddE GPG 0123456789 GPH P CHK 0123456789X These commands can be encoded into the following Aztec Code symbol OCR Template Codes Note Reading more than three rows of OCR is not recommended Contact the factory if you have an application that requires reading four or more rows of OCR On...

Page 204: ...9 14 2020 4820 4820 i User s Guide Exit Selections Save OCR Template Discard OCR Template ...

Page 205: ... that can be used with the image scanner Refer to page 2 14 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E US 1F _ ...

Page 206: ...CTRL column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 207: ... CR Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Backfield B...

Page 208: ... LF 0A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3 13 Back Space Back Space DC4 14 Back Tab Back Field NAK 15 F19 Reserved SYN 16 F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F6 PF6 FS 1C F7 PF7 GS 1D F8 PF8 RS...

Page 209: ... A N A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Escape Escape DLE 10 F11 F11 F11 DC1 11 Insert Insert Home DC2 12 F13 F13 Print DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Back Tab NAK 15 F12 F12 F12 SYN 16 F1 F1 F1 ETB 17 F2 ...

Page 210: ... EOT 04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3 13 BACKSPACE DC4 14 LSHIFT TAB NAK 15 F12 SYN 16 F1 ETB 17 F2 CAN 18 F3 EM 19 F4 SUB 1A F5 ESC 1B F6 FS 1C F7 GS 1D F8 RS 1E F9 US 1F F10 DEL 7F BACKSPACE ...

Page 211: ...ting that will be removed when the unit is power cycled Show Decoder Revision Scan the barcode below to output the decoder revision Show Engine Revision Scan the barcode below to output the engine revision It will return the engine type revision number and status character ACK For example an image scanner with a 5100 engine version 26 would return ENGREVType 1 Revision 26 ACK Show Scan Driver Revi...

Page 212: ...g this barcode causes the image scanner to re link with the base Image Scanner Report Scan the barcode below to generate a report for the connected image scanners The report indicates the port work group image scanner name and address To assign a name to your image scanner refer to Menu Command Syntax on page 12 1 Image Scanner Address Scan the barcode below to determine the address of the image s...

Page 213: ...terisk on the programming pages Note Scanning this barcode also causes both the image scanner and the base to perform a reset and become unlinked The image scanner must be placed in its base to re establish the link before any setup codes are entered Refer to Image Scanner Modes on page 3 5 for additional information Resetting the Standard Product Default Settings All Application Work Groups The f...

Page 214: ... your unit Visual Xpress provides a wide range of PC based programming functions that can be performed on an image scanner connected to your PC s COM port Visual Xpress allows you to download upgrades to the image scanner s firmware change programmed parameters and create and print programming barcodes Using Visual Xpress you can even save open the programming parameters for an image scanner This ...

Page 215: ... or save them to a dcf file Imaging Imaging provides all the image related functions that a 2D Image Scanner can perform You can capture an image using the current settings and the image will be displayed in an image window Images captured from the image scanner can be saved to files in different image formats You can modify the image settings and save the image settings to an INI file which can b...

Page 216: ...ownloading the file exit the web site 7 Using Explorer go to the c windows temp file 8 Double click on the Quickview exe file Follow the screen prompts to install the Quick View program 9 To start Quick View from the Start Menu click on Programs Quick View Quick View Note If you wish you can create a shortcut to the Quick View executable on your desktop Temporary Quick View Configuration For a qui...

Page 217: ... the following syntax spaces have been used for clarity only Prefix Name Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Name To send information to the image scanner with the base connect ed to host use 4820 or 4820i The default factory setting for a 4820 image scanner is 4820 and 4820i for a 4820i image scanner This setting is changed by ...

Page 218: ... place of a Tag field the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command In this case the SubTag and Data fields should not be used because they are ignored by the device SubTag Field Usage When a query is used in place of a SubTag field the query applies only to the subset of commands available that match the Ta...

Page 219: ...rks the period exclamation point comma or semicolon in the command Examples of Query Commands In the following examples a bracketed notation depicts a non displayable response Example 1 What is the range of possible values for Codabar Coding Enable Enter cbrena Response CBRENA0 1 ACK This response indicates that Codabar Coding Enable CBRENA has a range of values from 0 to 1 off and on Example 2 Wh...

Page 220: ...ters and the Default setting DFT has no value Trigger Commands You can activate and deactivate the image scanner with serial trigger com mands First the image scanner must be put in Manual Serial Trigger Mode either by scanning the Manual Serial Trigger Mode barcode page 4 4 or by sending the Manual Serial Menu Command page 12 10 Once the image scanner is in serial trigger mode the trigger is acti...

Page 221: ...enmark KBDCTY8 2 10 Finland Sweden KBDCTY2 2 10 France KBDCTY3 2 10 Germany Austria KBDCTY4 2 10 Greece KBDCTY17 2 10 Hungary KBDCTY19 2 10 Israel Hebrew KBDCTY12 2 10 Italy KBDCTY5 2 11 Latin America KBDCTY14 2 11 Netherlands Dutch KBDCTY11 2 11 Norway KBDCTY9 2 11 Poland KBDCTY20 2 11 Portugal KBDCTY13 2 11 Romania KBDCTY25 2 11 Russia KBDCTY26 2 11 SCS KBDCTY21 2 11 Slovakia KBDCTY22 2 11 Spain...

Page 222: ...AS2 2 14 Turbo Mode Off KBDTMD0 2 14 Turbo Mode On KBDTMD1 2 14 Numeric Keypad Off KBDNPS0 2 14 Numeric Keypad On KBDNPS1 2 14 Auto Direct Conn Off KBDADC0 2 15 Auto Direct Conn On KBDADC1 2 15 Baud Rate 300 BPS 232BAD0 2 16 600 BPS 232BAD1 2 16 1200 BPS 232BAD2 2 16 2400 BPS 232BAD3 2 16 4800 BPS 232BAD4 2 16 9600 BPS 232BAD5 2 16 19200 BPS 232BAD6 2 16 38400 BPS 232BAD7 2 16 57600 BPS 232BAD8 2 ...

Page 223: ...2 17 RS 232 Receiver Time out Range 0 300 seconds 232LPT 2 18 RS 232 Handshaking RTS CTS Off 232CTS0 2 18 RTS CTS On 232CTS2 2 18 XON XOFF Off 232XON0 2 18 XON XOFF On 232XON1 2 18 ACK NAK Off 232ACK0 2 18 ACK NAK On 232ACK1 2 18 Wand Emulation Connec tion Same Code Format TERMID64 2 22 Code 39 Format TERMID61 2 22 Data Block Size 20 WNDBLK0 2 22 40 WNDBLK1 2 22 60 WNDBLK2 2 22 80 WNDBLK3 2 22 Del...

Page 224: ...ry Charge Off BASCHG4 3 3 Image Scanner Modes Single Unlink Image Scanner BT_RMV 3 5 Locked Link Mode BASCON0 DNG 1 3 6 Open Link Mode BASCON1 DNG 1 3 6 Override Locked Image Scan ner BT_RPL1 3 6 Multiple Image Scanner Operation Multiple Image Scanner Oper ation BASCON2 DNG 3 3 7 Image Scanner Name Image Scanner Name BT_NAM 3 9 Image Scanner Report Image Scanner Report RPTSCN 3 10 Application Work...

Page 225: ...Sound Type Base Alarm Type BASORW 3 22 Image Scanner Alarm Type BT_ORW 3 22 Data Accumulation Mode On BATENA1 3 23 Off BATENA0 3 23 Batch Mode Transmit Delay Off BATDLY0 3 23 Short ms BATDLY250 3 23 Medium ms BATDLY500 3 23 Long ms BATDLY1000 3 23 Output Selections Beeper Good Read Off BEPBEP0 4 1 On BEPBEP1 4 1 Beeper Volume Good Read Off BEPLVL0 4 1 Low BEPLVL1 4 1 Medium BEPLVL2 4 1 Beeper Pitc...

Page 226: ...T3600 4 5 BT_LPT7200 4 5 Scan Stand Scan Stand Mode TRGMOD4 4 6 Scan Stand Symbol FNC3 4 6 Presentation Presentation Mode TRGMOD3 4 7 Presentation LED Timer LEDs Off TRGPCK0 4 7 LEDs On TRGPCK1 4 7 Presentation Sensitivity Range 0 20 1 TRGPMS 4 7 Streaming Presentation Streaming Presentation Mode TRGMOD8 4 8 Hands Free Time Out Range 0 300 000 ms TRGPTO 4 8 Reread Delay Short 500 ms DLYRRD500 4 9 ...

Page 227: ... 13 Top of Centering Window 40 DECTOP 4 13 Bottom of Centering Window 60 DECBOT 4 13 Decode Search Mode Full Omnidirectional Default for 2D image scan ners DECMOD0 4 14 Quick Omnidirectional DECMOD1 4 14 Preferred Symbology On PREFENA1 4 15 Off PREFENA0 4 15 High Priority Symbology PRFCOD 4 15 Low Priority Symbology PRFBLK 4 15 Preferred Symbology Timeout PRFPTO 4 16 Preferred Symbology Default PR...

Page 228: ...ctions Add CR Suffix to All Symbologies VSUFCR 5 3 Prefix Add Prefix PREBK2 5 4 Clear One Prefix PRECL2 5 4 Clear All Prefixes PRECA2 5 4 Suffix Add Suffix SUFBK2 5 4 Clear One Suffix SUFCL2 5 4 Clear All Suffixes SUFCA2 5 4 Function Code Transmit Enable RMVFNC0 5 4 Disable RMVFNC1 5 4 Intercharacter Delay Range 0 495 ms DLYCHR 5 5 User Specified Intercharacter Delay Delay Length 0 495 ms DLYCRX 5...

Page 229: ...ll Symbologies On ALLENA1 7 2 Codabar Default All Codabar Settings CBRDFT 7 3 Codabar Off CBRENA0 7 3 On CBRENA1 7 3 Codabar Start Stop Char Don t Transmit CBRSSX0 7 3 Transmit CBRSSX1 7 3 Codabar Check Char No Check Char CBRCK20 7 4 Validate But Don t Transmit CBRCK21 7 4 Validate and Transmit CBRCK22 7 4 Codabar Concatenation Off CBRCCT0 7 4 On CBRCCT1 7 4 Require CBRCCT2 7 4 Codabar Message Len...

Page 230: ...d 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 7 9 Interleaved 2 of 5 Off I25ENA0 7 9 On I25ENA1 7 9 Interleaved 2 of 5 Check Digit No Check Char I25CK20 7 10 Validate But Don t Transmit I25CK21 7 10 Validate and Transmit I25CK22 7 10 Interleaved 2 of 5 Mes sage Length Minimum 2 80 4 I25MIN 7 10 Maximum 2 80 80 I25MAX 7 10 Code 93 Default All Code 93 Settings C93DFT 7 11 Code 93 Off C93EN...

Page 231: ...f 5 Message Length Minimum 1 80 4 X25MIN 7 15 Maximum 1 80 80 X25MAX 7 15 Code 11 Default All Code 11 Settings C11DFT 7 15 Code 11 Off C11ENA0 7 15 On C11ENA1 7 15 Code 11 Check Digits Required 1 Check Digit C11CK20 7 16 2 Check Digits C11CK21 7 16 Code 11 Message Length Minimum 1 80 4 C11MIN 7 16 Maximum 1 80 80 C11MAX 7 16 Code 128 Default All Code 128 Settings 128DFT 7 16 Code 128 Off 128ENA0 7...

Page 232: ... Addenda Off UPAAD20 7 21 On UPAAD21 7 21 UPC A 5 Digit Addenda Off UPAAD50 7 21 On UPAAD51 7 21 UPC A Addenda Required Not Required UPAARQ0 7 21 Required UPAARQ1 7 21 UPC A Addenda Separator Off UPAADS0 7 21 On UPAADS1 7 21 UPC A EAN 13 with Extended Coupon Code On CPNENA1 7 22 Off CPNENA0 7 22 UPC E0 Default All UPC E Settings UPEDFT 7 22 UPC E0 Off UPEEN00 7 22 On UPEEN01 7 22 UPC E0 Expand Off...

Page 233: ... JAN 13 Check Digit Off E13CKX0 7 26 On E13CKX1 7 25 EAN JAN 13 2 Digit Addenda 2 Digit Addenda On E13AD21 7 26 2 Digit Addenda Off E13AD20 7 26 5 Digit Addenda On E13AD51 7 26 5 Digit Addenda Off E13AD50 7 26 EAN JAN 13 Addenda Required Not Required E13ARQ0 7 26 Required E13ARQ1 7 26 EAN JAN 13 Addenda Separator Off E13ADS0 7 27 On E13ADS1 7 27 ISBN Translate Off E13ISB0 7 27 On E13ISB1 7 27 EAN ...

Page 234: ...gth Minimum 4 48 4 MSIMIN 7 30 Maximum 4 48 48 MSIMAX 7 30 Plessey Code Default All Plessey Settings PLSDFT 7 30 Plessey Code Off PLSENA0 7 31 On PLSENA1 7 31 Plessey Message Length Minimum 4 48 4 PLSMIN 7 31 Maximum 4 48 48 PLSMAX 7 31 GS1 DataBar Omnidirec tional Default All GS1 DataBar Omnidirectional Settings RSSDFT 7 31 GS1 DataBar Omnidirec tional Off RSSENA0 7 31 On RSSENA1 7 31 GS1 DataBar...

Page 235: ...ck F Off CBFENA0 7 35 On CBFENA1 7 35 Codablock F Msg Length Minimum 1 2048 1 CBFMIN 7 35 Maximum 1 2048 2048 CBFMAX 7 35 Code 16K Default All Code 16K Settings 16KDFT 7 35 Code 16K Off 16KENA0 7 36 On 16KENA1 7 36 Code 16K Msg Length Minimum 0 160 1 16KMIN 7 36 Maximum 0 160 160 16KMAX 7 36 Code 49 Default All Code 49 Settings C49DFT 7 36 Code 49 Off C49ENA0 7 36 On C49ENA1 7 36 Code 49 Msg Lengt...

Page 236: ...NEMU2 7 40 EAN UCC 128 Emulation EANEMU1 7 40 EAN UCC Emulation Off EANEMU0 7 40 4 CB 4 State Customer Barcode On 4CBENA1 7 41 Off 4CBENA0 7 41 ID tag UPU 4 State On TAGENA1 7 41 Off TAGENA0 7 41 TCIF Linked Code 39 TLC39 On T39ENA1 7 41 Off T39ENA0 7 41 Postnet On NETENA1 7 42 Off NETENA0 7 42 Postnet Check Digit Transmit NETCKX1 7 42 Don t Transmit NETCKX0 7 42 Planet Code On PLNENA1 7 42 Off PL...

Page 237: ...efault All Korea Post Settings KPCDFT 7 46 Korea Post Off KPCENA0 7 46 On KPCENA1 7 46 Korea Post Msg Length Minimum 2 80 4 KPCMIN 7 46 Maximum 2 80 48 KPCMAX 7 46 QR Code Default All QR Code Settings QRCDFT 7 47 QR Code On QRCENA1 7 47 Off QRCENA0 7 47 QR Code Msg Length Minimum 1 3500 1 QRCMIN 7 47 Maximum 1 3500 3500 QRCMAX 7 47 Data Matrix Default All Data Matrix Set tings IDMDFT 7 48 Data Mat...

Page 238: ...1 Imaging Style Decoding SNPSTY0 8 2 Imaging Style Photo SNPSTY1 8 2 Imaging Style Manual SNPSTY2 8 2 Beeper On SNPBEP1 8 2 Beeper Off SNPBEP0 8 2 Exposure 1 7874 microsec onds SNPEXP 8 3 Gain None SNPGAN1 8 4 Gain Medium SNPGAN2 8 4 Gain Heavy SNPGAN4 8 4 Gain Maximum SNPGAN8 8 4 Delta for Acceptance 0 255 25 SNPDEL 8 4 LED State Off SNPLED0 8 3 LED State On SNPLED1 8 3 Wait for Trigger Off SNPTR...

Page 239: ...t KIM IMGFMT0 8 8 File Format TIFF binary IMGFMT1 8 8 File Format TIFF binary group 4 compressed IMGFMT2 8 8 File Format TIFF grayscale IMGFMT3 8 8 File Format Uncompressed binary IMGFMT4 8 8 File Format Uncompressed grayscale IMGFMT5 8 8 File Format BMP IMGFMT8 8 8 Histogram Stretch Off IMGHIS0 8 8 Histogram Stretch On IMGHIS1 8 8 Noise Reduction Off IMGFSP0 8 9 Noise Reduction On IMGFSP1 8 9 Inv...

Page 240: ...op 0 480 0 IMGWNT 8 11 Image Crop Bottom 0 480 479 IMGWNB 8 12 Image Crop Margin 1 238 0 IMGMAR 8 12 Protocol None raw IMGXFR0 8 12 Protocol None default USB IMGXFR2 8 12 Protocol Hmodem Com pressed IMGXFR3 8 12 Protocol Hmodem IMGXFR4 8 12 Ship Every Pixel IMGSUB1 8 13 Ship Every 2nd Pixel IMGSUB2 8 13 Ship Every 3rd Pixel IMGSUB3 8 13 Document Image Filter Off IMGUSH0 8 14 Document Image Filter ...

Page 241: ...OPQRSTU VWXYZ 9 9 OCR User Defined Check Char OCRCHK 9 10 3 1 3 1 Weighted Mod 10 Check Char OCRCHK3 1 3 1 9 10 2 1 2 1 Weighted Mod 10 Check Char OCRCHK2 1 2 1 9 11 OCR Templates Enter OCR Template OCRTMP 9 13 Enter User Defined Variable g OCRGPG 9 13 Enter User Defined Variable h OCRGPH 9 13 Minimizing Bluetooth ISM Band Network Activity Auto Reconnect Mode On BT_ACM1 16 1 Off BT_ACM0 16 1 Maxim...

Page 242: ...12 26 2020 4820 4820 i User s Guide ...

Page 243: ... Trigger Selections 20 inches 50 cm per second 4 inches 10 cm per second Symbol Contrast 45 minimum for Matrix codes 37 5 minimum for all others Battery Lithium Ion 3 6 Volt 1600 mAHr minimum Battery Capacity Standby Heavy Usage 1 scan per second 20 hours 12 hours minimum Storage 5 loss per month Radio Frequency 2 4 to 2 4835 GHz ISM Band Frequency Hopping Bluetooth v 1 2 Range 33 ft 10 m typical ...

Page 244: ...any TUV GS marked for I T E safety Mexico NOM NYCE COFETEL USA FCC Part 15 Subpart C UL listed to 60950 1 Canada RSS 210 cUL listed to CSA C22 2 No 60950 1 3 Parameter Specification Dimensions Typical Height 6 5 in 16 5 cm Length 5 3 inches 13 5 cm Width 3 2 inches 8 1 cm Weight 9 6 oz 272 g Aimer Illumination LEDs Aiming LEDs 626nm 30nm 526nm 30nm Image VGA 640x480 4X00 752x480 5X00 Binary TIFF o...

Page 245: ...o 104 F 5 C to 40 C Storage 40 to 158 F 40 to 70 C Humidity Up to 95 non condensing Mechanical Drop Operational after 50 drops from 6 5 feet 1 9 m to concrete Vibration Withstands 5G peak from 22 to 300 Hz ESD Sensitivity 15 kV to any external surface MTBF per MIL HDBK 217F Ground Benign exceeds 71 000 hours Sealant Rating IP54 Agency Compliance International CB Scheme to IEC60950 1 and IEC60825 1...

Page 246: ... will not charge 9 Volt DC Barrel 100 850mA 12 Volt Host 100 825mA Charge Rate 41 F to 104 F 5 C to 40 C 9 Volt DC Barrel external power Maximum 4 hours full charge for fully discharged battery Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Battery Charge 41 F to 104 F 5 C to 40 C Storage 40 F to 140 F 40 C to 60 C Humidity Up to 95 non condensing Mechanical Drop Operational after 50 drops...

Page 247: ... Japan Equipment Radio Regulations 2006 Australia NZ C Tick marked Europe CE 1995 5 EC R TTE Directive to EN55022 EN55024 EN61000 3 2 EN61000 3 3 2006 95 EC Low Voltage Directive Germany TUV GS marked for I T E safety Mexico NOM NYCE COFETEL USA FCC Part 15 Subpart C UL listed to 60950 1 Canada RSS 210 cUL listed to CSA C22 2 No 60950 1 3 ...

Page 248: ...able Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the base 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input Refer to tables on page 13 1 8 Keyboard data 9 Keyboard clock 10 ...

Page 249: ... to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 6 Barcode data output 7 Supply power input Refer to tables on page 13 1 8 9 10 Barcode data output Supply power input 9 Pin Type D Female connects to your terminal Supply ground Cord shield 1 2 3 4 5 6 7 8 9 ...

Page 250: ...Plug connects to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 Receive data Serial data to image scanner 6 Transmit data Serial data from image scanner 7 Supply power input Refer to tables on page 13 1 8 Request to send data 9 Clear to send data 10 ...

Page 251: ...2020 4820 4820 i User s Guide 13 9 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the base 1 2 Data 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data ...

Page 252: ...13 10 2020 4820 4820 i User s Guide ...

Page 253: ...h or lens tissue dampened with water or a mild detergent water solution If a detergent solution is used rinse with a clean lens tissue dampened with water only The image scanner and base s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the base s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere w...

Page 254: ... release clip 5 Replace with the new cable Insert the connector into the opening and press firmly The connector is keyed to go in only one way and will click into place Changing the Image Scanner Battery 1 Remove the screw on the end cap For a 4820 use a Phil lips screwdriver For a 4820i loosen the thumbwheel screw by hand or use a flat screw driver or hex wrench 2 Remove the battery from the hand...

Page 255: ...he coiled tether to the battery charge sleeve 2 Peel the backing from the metal plate on the coiled tether and affix the metal plate to the back of the 2020 base Note For best adhesion allow a 24 hour cure time before placing stress on the metal plate Remove Battery Remove the end cap of the image scanner turn the thumbwheel or use a hex wrench ...

Page 256: ... Base Note Please visit the Services and Support section of our website www handheld com to check for the latest software for both the image scanner and the base If your base is not functioning properly review the following troubleshooting guidelines to try to isolate the problem Is the red LED on If the red LED isn t illuminated check that The power cable is connected properly and there is power ...

Page 257: ...enter it the Enter Return key or the Tab key for example You need to program a suffix Programming a suffix enables the image scanner to output the barcode data plus the key you need such as CR to enter the data into your application Refer to Prefix Suffix Overview on page 5 1 for further information Does the image scanner read the barcode incorrectly If the image scanner reads a barcode but the da...

Page 258: ...14 6 2020 4820 4820 i User s Guide 2 If the image scanner still can t read the sample barcodes scan All Symbologies on page 7 2 ...

Page 259: ... Codabar Fm 0 1 a 0x61 Codablock F Om 0 1 4 5 6 q 0x71 Code 11 H3 h 0x68 Code 128 Cm 0 1 2 4 j 0x6A Code 16K Km 0 1 2 4 o 0x6F Code 32 Pharmaceutical PARAF X0 0x3C Code 39 Am 0 1 3 4 5 7 b 0x62 Code 49 Tm 0 1 2 4 l 0x6C Code 93 and 93i Gm 0 9 A Z a m i 0x69 Data Matrix dm 0 6 w 0x77 EAN 13 E0 d 0x64 EAN 8 E4 D 0x44 EAN UCC Composite em 0 3 y 0x79 EAN 13 with Extended Coupon Code E3 d 0x64 ID tag U...

Page 260: ... pm 0 1 2 W 0x57 Postnet X0 P 0x50 QR Micro QR Code Qm 0 6 s 0x73 Reduced Space Symbology GS1 DataBar GS1 DataBar Limited GS1 DataBar Expanded em 0 y 0x79 Straight 2 of 5 IATA two bar start stop Rm 0 1 3 f 0x66 Straight 2 of 5 Industrial three bar start stop S0 0 1 3 f 0x66 TCIF Linked Code 39 TLC39 L2 T 0x54 Telepen Bm 0 1 2 4 t 0x74 Trioptic Code X0 0x3D UCC EAN 128 C1 I 0x49 UPC A E0 c 0x63 UPC...

Page 261: ...cification Symbology Identifiers for AIM modifier character details Note Prefix Suffix entries for specific symbologies override the universal All Symbologies 99 entry Refer to Italics Data Editing beginning on page 5 1 and Italics Data Formatting beginning on page 6 1 for information about using Code ID and AIM ID ...

Page 262: ... 41 29 73 49 l 105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F O 111 6F o 16 10 DLE 48 30 0 80 50 P 112 70 p 17 11 DC1 49 31 1 81 51 Q 113 71 q 18 12 DC2 50 32 2 82 52 R 114 72 r 19 13 DC3 51 33 3 83 53 S 115 73 s 20 14 DC4 52 34 4 84 54 T 116 74 t 21 15 NAK...

Page 263: ...B Ë 235 EB ë 140 8C Œ 172 AC 204 CC Ì 236 EC ì 141 8D 173 AD 205 CD Í 237 ED í 142 8E Ž 174 AE 206 CE Î 238 EE î 143 8F 175 AF 207 CF Ï 239 EF ï 144 90 176 B0 208 D0 Ð 240 F0 ð 145 91 177 B1 209 D1 Ñ 241 F1 ñ 146 92 178 B2 210 D2 Ò 242 F2 ò 147 93 179 B3 211 D3 Ó 243 F3 ó 148 94 180 B4 212 D4 Ô 244 F4 ô 149 95 181 B5 µ 213 D5 Õ 245 F5 õ 150 96 182 B6 214 D6 Ö 246 F6 ö 151 97 183 B7 215 D7 247 F7 1...

Page 264: ... option is available for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Charac ters 3 CP Binary 82 ISO 2022 11 Swe Swedish Replacement Characters 83 ISO 2022 69 Fra French Belgium Replacement Characters 81 ISO 2022 25 Fra French Belgium Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 I...

Page 265: ...one 800 782 4263 E mail latechsupport handheld com Brazil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brsuporte handheld com Mexico Telephone 803 835 8000 E mail latechsupport handheld com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail eurosupport handheld com Asia Pacific Telephone Hong Kong 852 3188 3485 or 2511 3050 Telephone China 86 21 6361 3818 ...

Page 266: ...purchase record attached Contact the appropriate location below to obtain a Return Material Authorization number RMA before returning the product North America Telephone 800 782 4263 Fax 803 835 8012 E mail naservice handheld com Latin America Telephone 803 835 8000 Telephone 800 782 4263 Fax 239 263 9689 E mail laservice handheld com Brazil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brs...

Page 267: ...C static electricity or electro static discharge D operation under conditions beyond the specified operating parameters or E repair or service of the product by anyone other than Hand Held Products or its authorized representatives This warranty shall extend from the time of shipment for the duration published by Hand Held Products for the product at the time of purchase Warranty Period Any defect...

Page 268: ...RWISE EXCEED THE ACTUAL AMOUNT PAID TO HAND HELD PRODUCTS FOR THE PRODUCT THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HAND HELD PRODUCTS MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES LOSSES OR DAMAGES SOME STATES PROVINCES OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION...

Page 269: ...n barcode is scanned the image scanner begins the re link process immediately without user intervention Default Auto Reconnect On The table below shows the results of the Auto Reconnect On and Off settings Event Auto Reconnect On Auto Reconnect Off Image scanner out of range Re link occurs automatically If maximum number of link attempts see Maximum Link Attempts on page 16 2 is unsuccessful then ...

Page 270: ... image scanner will again try to link to the base unit When set to zero the image scanner will try to link until the Power Time Out Timer setting see page 4 4 expires Scan the Maximum Link Attempts barcode then scan the number of attempts for the setting from 0 100 from the inside back cover Scan Save to save the setting Default 0 Image scanner power down due to Power Time Out Timer setting see pa...

Page 271: ...e image scanner powers off and batch mode data is lost Maximum Link Attempts set to 15 Other values at default setting When the image scanner goes out of range 15 attempts are made to link to the base unit Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time After 15 cycles 8 15 120 or about 2 minutes the image scanner stops trying to connect to the ba...

Page 272: ...link Time Out set to 10 Image Scanner Power Time Out Timer set to 1800 Note See Image Scanner Power Time Out Timer on page 4 4 The image scanner attempts to connect to the base unit every 15 seconds measured from start of attempt to start of attempt After one half hour the image scanner powers off ...

Page 273: ......

Page 274: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 275: ... 00123456789012 PDF417 Postnet Code 49 Car Registration Zip Code 1234567890 Data Matrix QR Code Test Symbol Numbers Matrix 2 of 5 ID tag UPU 4 State J18CUSA8E6N062315014880T 4 CB 4 State Customer Barcode 01 234 567094 987654321 01234567891 ...

Page 276: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message OCR B with Modulo 10 check character OCR A with Modulo 36 check character ...

Page 277: ...OCR Programming Chart a e d g c h t l Discard Save r ...

Page 278: ...Programming Chart A C B F E D 1 0 2 3 ...

Page 279: ...Programming Chart 6 7 5 4 8 9 Save Discard Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again Reset ...

Page 280: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 4820 UG Rev D 3 08 ...

Reviews: