HAMPTON BAY H15E-NG11 Owners & Installation Manual Download Page 45

 

Hampton®H15E-11DirectVentFreestandingGasStove

  |    45

owner's information

COPY OF THE LIGHTING PLATE INSTRUCTIONS 

Part #: 919-089 - Side A

Colours: Black on white,  except for parts indicated as being Red.

       Punch out .25" hole top right corner where indicated.

Size:              100%

                         w- 6.7" x L- 9.95"

                

Mar 01/19:      Created decal

Material: 

Printable white polyester 7mm

Start serial sequence @ 000001

NOTE: This is a double sided decal

        

Part #: 919-089 - Side B

Colours: Black on white,  except for parts indicated as being Red.

       Punch out .25" hole top right corner where indicated.

Size:              100%

                         w- 6.52"

                         h- 11.13"

                

Aug. 14/17:     Created decal

A)    

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)  BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to the floor 

     because some gas is heavier than air and will settle on the floor.
       

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fire department.

C)   

Do not use this appliance if any part has been under water.  Immediately call a qualified service 

      technician to inspect the appliance and replace any part of the control system and any 

       gas control which has been underwater.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B)   AVANT LA MISE EN MARCHE

, reniflez tout autour de l’appareil pour déceler une odeur de gaz. Reniflez au niveau du plancher, car certains gaz 

sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.

      

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

    • Ne tentez pas d’allumer l’appareil

    • Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur. Suivez les instructions du fournisseur.

    • Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie.

C)   

N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter l’appareil par un technicien qualifié et remplacez 

tout élément du système de contrôle ou de commande qui a été plongé dans l’eau.

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, 

or Natural Gas and Propane Installation Codes, CSA B149.1. 

Cet appareil doit être installé conformément aux codes locaux, s’il y a lieu. En l’absence de tels codes, suivre le National Fuel Gas Code, 

ANSI Z223.1/NFPA 54, ou les Natural Gas and Propane Installation Codes, CSA B149.1.

CAUTION:  Hot while in operation. Do not touch. Severe burns may result. Due to high surface temperatures keep 

children, clothing and furniture, gasoline and other liquids having flammable vapors away. Keep burner and control 

compartment clean. See installation and operating instructions accompanying appliance.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or 

property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional 

information consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT : Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher 

un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles.

Tout défaut d'installation, de réglage, de modification, de service ou d'entretien peut entraîner des blessures ou des dom-

mages matériels. Reportez-vous au manuel d'utilisation fourni avec cet équipement. Pour obtenir de l'aide ou des informa-

tions complémentaires, consulter un installateur ou un service d'entretien qualifié, ou le fournisseur de gaz.

FOR YOUR SAFETY READ BEFORE LIGHTING

POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE

Part #:     920-089

Colour: 

Everything black on grey except for items indicated in red.

Size: 

  Printed at 100% 9.891’

’W x 6.213’

’H

Mar. 15/19: Created decal - Double-sized decal

*

Printer

: Start serial sequence at 089000001

C  2" / 50mm

E  2" / 50mm

A  6" / 150mm

B  0" / 0mm

Minimum ceiling height from top of unit:24"/610mm

Hateur min plafond depuis le haut de l'appareil: 

24"/610mm

Minimum clearance of V

ent 
Terminal 

 to Outside Corner & Inside Corner: 

with 
AstroCap 6"/150mm

with Dura-V

ent Cap 12"/300mm

Left Side W

all

Right Side W

all

Horizontal

Pipe

5"    WC/C.E. (1.25 kPa)

3.5" WC/C.E. (0.87 kPa)

1.6" WC/C.E. (0.40 kPa)

Minimum supply pressure

Manifold pressure High

Manifold pressure Low

Maximum Input

Minimum Input

Orifice size

Altitude

Pression d’alimentation minimale

Pression

manifold - 

lev
e

 

é
é

Pression

 - basse

 manifold

18,000 Btu/h (5.28 Kw/h)

12,700 Btu/h (3.72 Kw/h)

#47 DMS       

0-4500 ft/pi   (0-1372m)

D

bit calorifique maximalé

D

bit calorifique minimalé

Taille de l'orifice

Altitude

11"    WC/C.E.   (2.74 kPa)

10" WC/C.E.      (2.49 kPa)

6.4" WC/C.E.     (1.59 kPa)

Minimum supply pressure

Manifold pressure High

Manifold pressure Low

Maximum Input

Minimum Input

Orifice size

Altitude

Pression d'alimentation minimale

Pression

manifold - 

lev
e

 

é
é

Pression

manifold - basse 

18,000 Btu/h     (5.28 Kw/h)

15,500 Btu/h     (4.54 Kw/h)

#55 DMS        

0-4500 ft/pi       (610-1372m)

D

bit calorifique maximalé

D

bit calorifique minimalé

Taille de l'orifice

Altitude

Left Side W

all

Right Side W

all

Vertical

Pipe

See Manual for details / 

Voir manuel pour plus de détails

Model/Modèle:

H15E-LP11

PROP

ANE GAS ST

OVE: 

Model H15E-LP1

1

          APP

AREIL

 FONCTIONNANT 

AU PROP

ANE

          

Modèle H15E-LP1

1

                          

 

DO NOT REMOVE THIS LABEL

 / NE P

AS ENLEVER CETTE ÉTIQUETTE 

                     

468

DUPLICA

TE SERIAL

 NO.

FPI Fireplace Products International Ltd.

Delta, BC, Canada

Made in Canada/Fabriqué au Canada

Minimum Clearances to Combustibles /

Dégagements minimaux

par rapport aux matériaux combustibles

Serial No./ No de série

This appliance must be installed in accordance with local

 codes, if any; if none, follow the National Fuel Gas Code, 

ANSI Z223.1, or Natural Gas and Propane Installation 

Code, CSA

 B149.1.

This 

appliance 

must 

be 

installed 

in 

accordance 

with 
the 
Standard 

CAN/CSA

 Z240 

MH, 

Mobile 

Housing, 

in 

Canada, 

or 

with 
the 
Manufactured 

Home 

Construction 

and 
Safety 

Standard, T

itle 
24 
CFR, 

Part 

3280, 

in 

the 
United 

States, 

or 

when 

such 

standard 

is 

not 
applicable, 

ANSI/NCSBCS 

A225.1/NFP

A 501A, 

Manufactured 

Home 

Installations 

Standard 

or 

ANSI 

A1

19.2 

ou 

NFP
A 501C 

Standard 

for 

Recreational 

Vehicles.

This 

appliance 

is 

only 
for 

use 
with 
the 
type 

of 

gas 
indicated 

on 

the 
rating 

plate 

and 
may 

be 

installed 

in 

an 

aftermarket, 

permanently 

located, 

manufactured 

(mobile) 

home 

where 

not 
prohibited 

by 

local 

codes. 

See 
owner's 

manual 

for 

details. 

Optional 

Fan 
Kit 

(Part 

382-917)

Installer 

l'appareil 

selon 

les 
codes 

ou 
règlements 

locaux, 

ou, 
en 
l'absence 

de 
tels 
règlements, 

selon 

les 
codes 

d'installation 

ANSI 

Z223.1, 

National 

Fuel 

Gas 

Code 

ou 
CSA-

B149.1 

en 

vigueur

.

Installer 

l'appareil 

selon 

la 

norme 

CAN/CSA-Z240, 

Série 

MM, 

Maison 

mobiles 

ou 

CAN/CSA-Z240 

VC, 
Véhicules 

de 

camping, 

ou 

la 

norme 

24 

CFR 

Part 

3280, 

Manufactured 

Home 

Construction 

and 
Safety 

Standard. 

Si 

ces 
normes 

ne 
sont 

pas 
pertinentes, 

utilisez 

la 

norme 

ANSI/NCSBCS 

A225.1/NFP

A 501A, 

Manufactured 

Home 

Installations 

Standard, 

ou 

ANSI 

A1

19.2 

ou 

NFP
A 501C 

Standard 

for 

Recreational 

Vehicles.

Cet 
appareil 

doit 
être 
utilisé 

uniquement 

avec 

le 

type 

de 

gaz 
indiqué 

sur 
la 

plaque 

signalétique. 

Cet 
appareil 

peut 

être 
installé 

dans 

une 
maison 

préfabriquée 

ou 

mobile 

(É.-U. 

seulement) 

installée 

à 

demeure 

si 

les 
règlements 

locaux 

le 

permettent. 

Voir 

la 

notice 

de 
l'utilisateur 

pour 

plus 

de 
renseignements. 

Cet 
appareil 

ne 
peut 

pas 
être 
utilisé 

avec 

d'autres 

gaz 
sauf 

si 

une 
trousse 

de 

conversion 

certifiée 

est 
fournie.

 

This 

vented 

gas 
fireplace 

heater 

is 

not 
for 
use 
with 

air 

filters.          

Ne 
pas 
utiliser 

de 

filtre 

à 

air 

avec 

ce 

foyer 

au 

gaz 
à 

évacuation.                                                    

                                      

For 
use 
with 
glass 

doors 

certified 

with 
the 
appliance 

only
.                      

À 

utiliser 

uniquement 

avec 

les 
portes 

vitrées 

certifiées 

avec 

l'appareil.

468

Model/Modèle:

H15E-NG11

NA

TURAL

 GAS ST

OVE: 

Model H15E-NG1

1

           APP

AREIL

 FONCTIONNANT 

AU GAZ NA

TUREL

           

Modèle H15E-NG1

1

VENTED GAS FIREPLACE HEA

TER - 

NOT FOR USE WITH SOLID FUELS. 

NE P

AS UTILISER 

AVEC UN COMBUSTIBLE SOLIDE. 

FOYER 

AU GAZ À ÉV

ACUA

TION - 

ELECTRICAL

 SUPPL

Y/ALIMENT

ATION ÉLECTRIQUE:

115V_60HZ less than/moins de 2 

AMP

For Use Only with Barrier (Part # 382-005) Follow installation 

instructions.          

Utiliser uniquement avec l’écran de sécurité (pièce n°382-005).

 Suivre les consignes d'installation.

C #: 4001

172

MA
Y BE INST

ALLED IN MANUF

ACTURED (MOBILE) HOMES 

AFTER FIRST SALE

.

Listed/Nom:

 VENTED GAS FIREPLACE  / FOYER 

AU GAZ À ÉV

ACUA

TION

Certified to/Certifi

 : é

ANSI Z21.88-2017 • CSA-2.33-2017

                                    CSA

 2.17-2017

                    

Refer to Intertek's Directory of Building Products for detailed

 information.

Pour plus de détails, se reporter au Répertoire des produits de

 construction de Intertek. 

920-089

CSA
 P

.4.1 Fireplace Ef

ficiency (FE) /

Ef

ficacité énergétique des foyers (EEF) CSA

 P

.4.1

Natural Gas / Gaz naturel 55.33%

Propane Gas / Gaz propane 57.46%

CANADIAN ENERGY

 

PERFORMANCE 

VERIFIED

RENDEMENT

 

ÉNERGÉTIQUE 

VÉRIFIÉ

EP501

1169

Summary of Contents for H15E-NG11

Page 1: ...ng Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Inst...

Page 2: ...nuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position in your remote control transmitter Each time the main burner shuts down manually or throu...

Page 3: ...ns 8 Mobile Manufactured Homes After First Sale 8 Before You Start 8 Lighting Procedure 9 Copy of the Lighting Plate Instructions 10 Proflame II remote control operating Instructions 11 Dura Vent Term...

Page 4: ...RIZONTAL VENT 22 7 8 19 3 8 24 11 16 20 11 16 17 13 16 19 1 8 14 1 4 13 5 8 21 1 4 19 1 8 525mm 451mm 485mm 540mm 626mm 581mm 492mm 345mm 485mm 361mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL...

Page 5: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 5 dimensions UNIT DIMENSIONS WITH VERTICAL VENT...

Page 6: ...bited by local codes See owner s manual for details Optional Fan Kit Part 382 917 Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon les codes d install...

Page 7: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in s...

Page 8: ...ds to make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPL...

Page 9: ...ystem will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF switch or press ON OFF button if...

Page 10: ...cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez tout l ment du syst me de contr le ou de commande qui a t plong dans l eau...

Page 11: ...simple button layout and informative LCD display Fig 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Fig 1 2 Ad...

Page 12: ...height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the...

Page 13: ...oflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adju...

Page 14: ...the fireplace is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as fo...

Page 15: ...bedding material etc It is imperative that control compartments and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction a...

Page 16: ...of the figures but the connector is too close move the stove until the correct clearance to the connector is obtained This appliance may be installed only with the clearances as shown in the situation...

Page 17: ...the legs as shown On either side of the unit there will be slits located on the body of the stove Slide the fan up into the slits until the mounting holes line up with the holes locatedonthefanassemb...

Page 18: ...tem perature 2 Lift off cast top and place on a soft surface 4 Slide the light assembly bracket out of the way 5 Lift both latches securing glass door and re move door 6 To reinstall reverse steps 3...

Page 19: ...s products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room a...

Page 20: ...f center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air in...

Page 21: ...Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A...

Page 22: ...for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Te...

Page 23: ...t Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing o...

Page 24: ...t with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 fee...

Page 25: ...Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Lengths do not include elbow indicated Vent restrictor position A fully open refer to the Vent Restrictor Position section One 90o elbow Two 45o elbow Option V H...

Page 26: ...ontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with hori zontal terminations Maximum one 90O elbow two 45o elbows equ...

Page 27: ...flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will accommodate However...

Page 28: ...pe to length Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimped section of rigid pipe seats...

Page 29: ...on hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia fle...

Page 30: ...1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws 1 946 219 p Pipe Adaptor 380 946 Horizon...

Page 31: ...ter wall of the vent pipe and nearby combustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements from decks windows soffits gas regulators air supply inlets and pub...

Page 32: ...r mination Neverallowtheventtorundownward This could cause high temperatures and may present the possibility of a fire b The location of the horizontal vent termina tion on an exterior wall must meet...

Page 33: ...ommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Diagram 5 c Before connecting the ve...

Page 34: ...is installed under the roofing material and not nailed down until the chimney is installed This allows for small adjustments Note If an offset is necessary in the attic toavoidobstructions itisimporta...

Page 35: ...Pilot Ignition atalltimes Thiswillavoidnuisance pilot outages during operation of this appli ance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the di...

Page 36: ...e chimney in a convenient location as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the...

Page 37: ...specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do...

Page 38: ...6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold...

Page 39: ...enter Front Log e Embers f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log 4 Remove Glass front see instructions in manual 3 Remove Cast Front and set the light as...

Page 40: ...of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top 8 Take the embers and place on the burner...

Page 41: ...Open the right when facing front of appliance access panel by removing 1 screw 2 Install 4 AA batteries into the battery holder Note Remove the batteries when normal opera tion is resumed as the heat...

Page 42: ...ed with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong...

Page 43: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 43 operating instructions WIRING DIAGRAM WITH THERMOSTAT RESET SWITCH Thermostat Optional Millivolt...

Page 44: ...the glass while it is hot DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE starting operatingtheappliance pleasereadthe remote control operating instructions packed with remote control to u...

Page 45: ...cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez tout l ment du syst me de contr le ou de commande qui a t plong dans l eau...

Page 46: ...me pattern has two strong blue flames 1 flowing around the flame sense and 1 flowing across the rear of the burner it does not have to be touching the burner Note If you have an incorrect flame patter...

Page 47: ...rior portions of the system being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Alsocheckmechanicalsupportssuch as...

Page 48: ...ff cast front place front carefully on a soft surface 1 Turn off stove and allow to return to room temperature 2 Shut off electrical supply 3 Lift off cast top and place on a soft surface Lift light a...

Page 49: ...out of the way Screws 7 Carefully remove the logs and embers 8 Remove burner by removing the 2 screws on each side and then lifting the burner tray out Note Use a magnetic type screwdriver if pos sib...

Page 50: ...the list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Oper...

Page 51: ...Comes WithLegs 2PerSide Brown 383 227 Cast Left Right Side Comes WithLegs 2PerSide Cream W801015 Touch Up Paint Brown 938 337 Touch Up Paint Cream 9 382 515 Rear Panel Assembly 11 382 516 Valve Cover...

Page 52: ...Proflm II 7day PV 5 Sec FFRT 0 584 625 911 175 Hand Held Remote Control GTMFL 0 584 042 911 179 ASM 120 Volt Power Cord Assembly 911 173 Valve Remote Wiring Harness 584 924 911 177 4 Position Wire Ha...

Page 53: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 53 notes...

Page 54: ...Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Cryst...

Page 55: ...ndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of...

Page 56: ...de the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the autho...

Page 57: ...low in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Produc...

Page 58: ......

Page 59: ...Hampton H15E 11 Direct Vent Freestanding Gas Stove 59...

Page 60: ...me Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Ph...

Reviews: