![HAMPTON BAY H15E-NG11 Owners & Installation Manual Download Page 25](http://html1.mh-extra.com/html/hampton-bay/h15e-ng11/h15e-ng11_owners-and-installation-manual_3521998025.webp)
Hampton®H15E-11DirectVentFreestandingGasStove
| 25
installation
H1
H
V
Vertical Venting with Two (2) 90
o
Elbows
Vertical Venting with Two (2) 90
o
Elbows
V1
V
H
One 90
o
elbow = Two 45
o
elbow
Option
H + H1
V
Withtheseoptions,maxi-
mum total pipe length is
30 feet with minimum of
6 feet total vertical and
maximum 6 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
2'Max.
2'Min.
B)
3'Max.
3'Min.
C)
4'Max.
4'Min.
D)
5'Max.
5'Min.
E)
6'Max.
6'Min.
Lengthsdonotincludeelbowindicated.
VentrestrictorpositionA(fullyopen),refertothe"Vent
RestrictorPosition"section.
One 90
o
elbow = Two 45
o
elbow
Option
V
H
V + V1
With these options, maxi-
mumtotalpipelengthis30
feetwithminimumof6feet
totalverticalandmaximum
8feettotalhorizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
1'Min.
4'Max. 2'Min.
B)
2'Min.
5'Max. 3'Min.
C)
3'Min.
6'Max. 4'Min.
D)
4'Min.
7'Max. 5'Min.
E)
5'Min.
8'Max. 6'Min.
Lengthsdonotincludeelbowindicated.
VentrestrictorpositionA(fullyopen),refertothe"VentRestric-