Hampton®H15E-11DirectVentFreestandingGasStove
installation
4) AssemblethedesiredlengthsofBlackPipeand
Elbowsnecessarytoreachfromtheappliance
adapterupthroughthesupportboxandflash-
ingtoproperheightasperDia.12,localcodes.
Ensurethatallpipeandelbowconnectionsare
intheirfullytwistlockposition.
5) Ensureventisverticalandsecureflashingto
theroofwithroofingnails.Slidethestormcollar
overthepipesectionandsealwithamastic.
6) Twistlocktheventcapontothelastsection.
Support Extensions - Round (RDSE)
or Square (SQSE)
Steeppitchedcathedralceilingsmayrequirethe
useofasupportextension.Thispiecefitsdown
insidethesupportandcanbeadjustedtoincrease
thesupport'slengthbyupto22".Theextensionis
attachedtothesupportusingtheeightmetalscrews
provided.Besurethereisatleasta2inchoverlap
wheretheextensionjoinsthesupport.
HIGH ELEVATION
ThisunitisapprovedinCanadaforaltitudeto4500ft.
(CAN/CGA-2.17-M91).ForNaturalGasinstallations
above4500ft.followcurrentCAN/CGA-B149.1.
GAS CONNECTION
Thegasconnectionisa3/8"NPT90
o
elbow.The
gaslinecanberigidpipeortomakeinstallation
easier,usealistedflexibleconnectorand/orcop-
pertubingifallowedbylocalcodes.Sincesome
municipalitieshaveadditionallocalcodesitisalways
besttoconsultwithyourlocalauthoritiesandthe
CAN/CGAB149installationcodes.
ForUSAinstallationsfollowlocalcodesand/orthe
currentNationalFuelGasCode,ANSIZ223.1.
When using copper or flex connectors use only
approvedfittings.Alwaysprovideaunionsothat
gas lines can be easily disconnected for burner
and/orvalveservicing.Flarenutsforcopperlines
andflexconnectorsareusuallyconsideredtomeet
thisrequirement.
CATHEDRAL CEILINGS
Round Support (RDS) &
Square Support (SQS)
Ifyourhomehasacathedralceiling(noatticspace
betweentheceilingandtheroof),installthechimney
andsupportasfollows.
1) Situatethechimneyinaconvenientlocation
asnearaspossibletotheapplianceoutlet.Cut
andframeaholeintheroofforthesupport.The
sidesofthisholemustbeverticalwith1-1/4"
clearance.
2) Placethesupportintheopening.Loweritto
thecorrectheightasdeterminedbythetable
anddiagrambelow.
Usingalevel,makesurethesupportisvertical.
Ifthesupportextendsabovetheroof,cutit
flushwiththetopoftheroof.Nailthesupport
totheframeopeningusing(8)3"spiralnails
or#8x1-1/2"screws.
Note: If you are using a 6" square support you
may find it difficult to screw it in place
because it is fairly small inside.
SimpsonDura-Venthasprovidedanglebrack-
etswiththissupportwhichcanbescrewed
totheoutsideofthesupportboxandnailed
to surroundingframingas required.Use a
minimumoffour#8x1/2"screwsperbracket.
Insomecasesthesebracketsmayneedtobe
trimmed(e.g.:tofitunderaflashing).Place
theFinishCollararoundthesupportandfasten
ittotheceilingusingthescrewsprovided.
3) Useappropriateroofflashing.Placetheflash-
ingundertheuppershinglesandontopofthe
lowershinglesapproximatelyhalfoftheflashing
shouldbeundertheshingles.
Slope
"X"
0/12 -2/12
4"
2/12 -7/12
5-1/2"
7/12 -12/12
6-3/4"
12/12 -24/12
7-1/2"
24/12+
12-1/2"
IMPORTANT:
ALWAYS CHECK FOR GAS
LEAKS WITH A SOAP AND WATER SOLU-
TION OR GAS LEAK DETECTOR. DO NOT
USE OPEN FLAME FOR LEAK TESTING.
Note: Prior to any pressure testing of the gas
supply piping system that exceeds test
pressures of 1/2 psig, this appliance
must be disconnected from the piping
system. If test pressures equal to or less
than 1/2 psig are used then this appli-
ance must be isolated from the piping
system by closing its individual manual
shut-off valve during the testing.
H15E-NG11 System Data
For0to4500feetaltitude
Burner Inlet Orifice Sizes:
#47
Max. Input Rating 18,000Btu/h
Min. Input Rating
12,700Btu/h
Supply Pressure
min.5.0"w.c.
Manifold Pressure
(High)
3.5"w.c.
H15E-LP11 System Data
ConversionKit
For0to4500feetaltitude
Burner Inlet Orifice Sizes:
#55
Max. Input Rating 18,000Btu/h
Min. Input Rating
15,500Btu/h
Supply Pressure
min.11.0"w.c.
Manifold Pressure
(High)
10"w.c.