Hampton®H15E-11DirectVentFreestandingGasStove
installation
DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION
Reviewthefollowingsequenceofinstructions
whicharetypicalofmostinstallations.These-
quencemayvarydependingonwallthickness.
Refer to the "Exterior Vent Terminal Loca-
tions" and "Rigid Pipe Venting Systems"
sections for vent location and clearance
dimensions, and the "Vent Restrictor Posi-
tion" for the correct positioning.
1) Settheunitinitsdesiredlocation.Check
todetermineifwallstudswillbeintheway
oftheventingsystem,adjustlocationuntil
all clearances are met and there are no
obstructions.
Note: A 1-1/2"(38mm) clearance around the
outer pipe must be maintained except
that only a 1" (25mm) clearance is
needed at the termination end.
IMPORTANT:
Do not locate termination hood
where excessive snow or ice
buildup may occur. Be sure to check
vent termination area after snow
falls, and clear to prevent accidental
blockage of venting system. When
using snow blowers, make sure
snow is not directed towards vent
termination area.
b) Install wall thimbles on both interior
andexteriorwallwith4woodscrews
(#8x1")perthimble.
c) Attachthe2pieceadjustablepipesec-
tiontotheventterminalandslideinto
positionfromtheexterior.
The larger
diameter end of the adjustable pipe
goes to the vent terminal.
d) Installthe90
o
elbowontotheadjust-
able pipe to determine the vertical
centerline.
Note: if the centerline cannot be met,
the adjustable sections will have to
be cut.
e) Cut the 4 ft. section of rigid pipe to
length.Attachthe45
o
elbowtotherigid
pipe,andensurethatthepipelength
whencut(withthe45
o
elbow)willseat
onto both the starter collar and the
90
o
elbow.
Crimped section of rigid
pipe seats into the 90
o
elbow. Only
cut the uncrimped side of pipe.
Dismantleallpipesectionsincludingvent
terminal.
2) Assemblea
trial fittodeterminethevertical
center-linefortheventtermination.
a) Cut a 9-1/2" x 9-1/2" (241mm x 241
mm) square hole on both the interior
andexteriorwall.
DV STOVE HORIZONTAL VENT KIT
DV2ft.StoveVentKit(Part#946-116)andDV4ft.StoveVentKit(946-216)includesallthepartsneededto
installtheH15-10DirectVentunitwithup&outhorizontalandverticalventdimensions.Forinstallationsthat
requirelongerverticaland/orhorizontalventsusetheDura-Ventsystemasshowninthe"Dura-VentTermina-
tionKit"and"Dura-VentVentingComponents"sections.
Qty.
Description
1) 1 RigidPipeSection(Kit#946-116:2ft.(1.2m)length,
Kit#946-216:4ft.(1.2m)length),6-1/2"(165mm)
insidediameter
2) 1 FlexLiner,compressedaluminium2plyliner,4"(102mm)
insidediameter
3) 4 springspacers
4) 1 90deg.Elbow
5) 1 Adjustablepipesection13-1/2"to24"(343mmx610mm),2pcs.
6) 1 ThimbleCover
7) 1 WallThimble(2pcs.)
8) 1 Adapter
9) 1 AstroCapTerminationCap
10)2 TrimCollars
11)1 tubeofMill-Pac,hightemperaturesealant
12)12 Screws,#8x1/2"Selftapping,StainlessSteel
13)14 Screws,#8x1/2"Selftapping,Black
14)4 Screws#8x1-1/2"DrillPoint,Black
15)4 Screws#8x1-1/2"DrillPoint,StainlessSteel
16)8 Woodscrews#8x1"
Note:
a) Liner sections should be con-
tinuous without any joints or
seams.
b) This is an approved system,
therefore components in this
system must not be substituted
for any other manufacturer's
products.