Bit 1
:
Drag error
set:
- If the set maximum speed is not reached after the end of the acceleration
phase
reset:
- with each new run command
Bit 2
:
Reverse jog key active
set:
- If Pin 3 of the key connector is connected with Pin 1 (+24V),
reset:
- If Pin 3 of the key connector is disconnected with Pin 1 (+24V),
Bit 3
:
Forward jog key active
set:
- If Pin 2 of the key connector is connected with Pin 1 (+24V),
reset:
- If Pin 2 of the key connector is disconnected with Pin 1 (+24V),
Bit 4
:
Motor power present
set:
- If the motor supply voltage is above the Umot limit (ISDU 181) and below
30V
reset:
- If the motor supply voltage is below the Umot limit or above 30V
Bit 5
:
Positioning run aborted
set:
- if a positioning run is cancelled by cancelling the release in the control word
reset:
- when a new run command is sent
Bit 6
:
Drive is running
set:
- with rotating drive
reset:
- at standstill
Bit 7
:
Temperature exceedance
set:
- If the temperature inside the device exceeds the limit value from ISDU 182
deleted:
- If the temperature inside the device exceeds the limit value by 5°C
Bit 8
:
Movement opposite loop direction
set:
- for manual drive against the positioning direction (a subsequent manual
travel in positioning direction no longer deletes this bit)
- during a positioning operation against the loop direction
reset:
- After a successful arrival to a transferred target position in loop direction
- after a initial reference loop
Bit 9
:
Error
set: