Instruction Manual PSx3xxIO
13
Designation
ISDU
Number
Function
Value
range
Secu
red
Delivery R/W
“Bus communication” parameter group
Process data
format
116
0
with time stamp function
1
with 6 bytes of output data
After saving and restarting, the device
reports with the Device ID which
corresponds to the gearbox type:
with time stamp function
odd ID (e.g. 312080
1
)
with 6 bytes of output data
even ID (e.g. 312080
2
)
0
…1
8 bit
yes
1
R/W
Communicati
on timeout
118
Value in milliseconds
If the value is 0, the communication
timeout is disabled. A value > 0 defines
the time within which the master must
send a new message to maintain the
connection. A timeout either results in a
drive cancellation (value of ISDU 137 = 1)
or a drive to the safety position defined by
ISDU 138(value of ISDU 137 = 2).
0
…
10000
16 bit
yes
0
R/W
Stack
behaviour
119
Bit 0: Device sends diagnostic messages
All other bits must be set to 0!
8 bit
yes
1
R/W