Supplied By www.heating spares.co Tel. 0161 620 6677
15
FIBRE
SEAL FITTED
INTERNAL WALL
SEALING RING
130mm Dia.
HOLE WITH
WALL LINER
TOP
EXTERNAL WALL
SEALING RING
1
INSERT
ASSEMBLED
FLUE SYSTEM
FROM INSIDE
THE ROOM.
EXTERNAL
WALL
SEALING RING
OPENS
2
ALIGN ASSEMBLED FLUE
SYSTEM ELBOW TO
APPLIANCE AND SECURE
3
SLIDE
INTERNAL
WALL
SEALING RING
TO WALL TO
FORM A GOOD
SEAL
INSTALLING THE AIR/FLUE DUCT
FROM INSIDE THE ROOM
4.8.1
ELECTRICAL CONNECTIONS
4.9
Wall thickness up to 800 mm (31in) only.
a)
Push the terminal through the wall liner taking care to ensure that
the terminal is the correct way round and the external wall-sealing
ring does not become dislodged.
b)
Assemble the flue system extension ducts as necessary, referring
to Figure 15.
c)
Pull the flue system towards the appliance to seat the external
sealing ring against the outside wall, ensuring that the duct joints
are not disturbed.
d)
Use the internal sealing ring to make good the internal hole, and
check that the terminal is correctly located on the outside wall
(Where possible this should be visually checked from outside the
building.) Figure 16 shows a view of the flue system, correctly
installed.
e)
Finally locate and secure the elbow to the appliance using the four
screws provided.
INSTALLING THE AIR/FLUE DUCT
FROM OUTSIDE THE ROOM
4.8.2
(Flue hole diameter 100 mm - wall liner not necessary)
a)
Secure the flue elbow with seal to the appliance using 4 screws.
b)
Fit external wall sealing ring over flue and then from outside the
building, push the flue system through the wall taking care to
ensure that the terminal is the correct way around.
c)
Loosely fit the internal wall sealing ring over the inside end of the
flue.
d)
Assemble the flue system extension ducts as necessary, referring
to the flue kit instructions, and fit to the flue elbow.
e)
Fit the flue terminal to the flue system, ensuring that the duct joints
are not disturbed, and that the external sealing ring is seated
against the outside wall.
f)
Finally use the internal sealing ring to make good the internal hole.
Check that the external wall sealing ring and the terminal is
correctly located, on the outside wall from outside the building.
Connect the electricity supply and external controls (using suitable
mains cable) as follows:
Wire the cable(s) into the appropriate connections in the electrical plug
provided, referring to Figure 16. Live supply to L1, Neutral and Earth as
indicated. Check that L2 and L3 are linked.
To provide correct cable retention, fit the piece of tubing supplied over
the cable as it passes through the clamping arrangement. The cable will
be held in position as the plug cover is fitted.
If a programmer/room thermostat is to be fitted remove the red link
between L2 and L3 and connect the device across these terminals. Any
external controls fitted must be rated at 230V 50Hz and have volt free
contacts.
OPTIONAL CYLINDER/TANK TEMPERATURE
SENSOR (SBX APPLIANCES ONLY)
4.10
If this sensor kit is used, refer to the separate kit for instructions for
installation and wiring details.
16
NOTE:
If room
thermostat is to be
fitted, remove the link
and connect room
thermostat across L2
and L3
20
751030 MANUAL (NEW) 21/9/10 08:44 Page 42