20
21
INLET PRESSURE TEST POINT
NOTE:
On the CBX 38, the
inlet pressure test
point is situated on
the gas service cock.
DHW FLOW RATE (CBX APPLIANCES ONLY)
5.3
LOCKOUT INDICATION
5.5
A flow regulator is supplied factory fitted to the appliance to ensure that
no adjustment is necessary. Should the mains flow rate be below the
minimum required, it is possible to remove the flow regulator from the
appliance as instructed in section 9. The nominal pre-adjusted flow rate
may vary by ± 5 % due to factory tolerances and mains water pressure
fluctuation.
In the event of failure during an ignition sequence, (5 attempts) the
Reset
LED will show steady RED. By pressing and holding the
Reset
button for 3 seconds the
Reset
LED will flash RED and LEDs 1 to 4 will
display the error code (0011). To
Reset
the appliance and initiate a
further ignition attempt, press the
Reset
button.
NOTE:
In the event of failure during normal running, the Reset LED will
show steady RED.
To access the relevant error codes, press the
Reset
button for three
seconds. The
Reset
LED will flash RED. To reset the appliance press the
Reset
button. Refer to 'fault finding' Section 8.
FINAL CHECKS
5.4
a)
Turn both the DHW and CH temperature control knobs to standby.
b)
Turn the appliance on/off switch to the off ('O') position, remove the
manometer and tighten the appliance inlet pressure test point
screw. Re-light the burner and test for gas tightness.
c)
Fit the appliance casing as described and illustrated in Figure 21: Fit
each side panel with two screws at the top and bottom of each panel.
Position and fit controls cover in place using screws provided.
Ensure it hinges correctly. Fit the front panel in position using
locating studs and ensure it’s correctly seated by pressing.
d)
Set the heating and hot water controls to the required settings. For
CBX appliances ensure that the clock override switch is in the timed
position and check that the time clock is set at the desired time
periods. Set the room thermostat (if fitted) to the required setting.
e)
For SBX appliances if the cylinder / tank sensor if fitted set the hot
water sensor to the required setting. Refer to separate cylinder /
tank sensor instructions.
FROST PROTECTION
5.6
The appliance is fitted with a frost protection device. In the event of very
cold conditions, the pump may operate and the appliance light for a few
minutes to protect the appliance and system from potential frost
damage. This can only function if the gas and electricity supplies are
maintained and the ON/OFF switch on the appliance is left ON. (‘l’) On
CBX appliances the time clock can be switched to the OFF setting.
OVERHEAT PROTECTION
5.7
The appliance incorporates flow and return thermostats, which monitor
the appliance's operating temperature. Abnormal temperatures such
as overheating will cause the appliance to go to lockout and the
Reset
button will show steady RED, if the error codes are accessed the LED 4
(code 0001) will illuminate. Allow the appliance to cool, and then press
the
Reset
button to clear.
CASING
SIDE PANEL
SECURING SCREWS
(4 PER SIDE)
BALL STUD
RUBBER GROMMET
LOWER DOOR
HINGE FIXINGS
(M4 SCREWS)
RUBBER
GROMMETS
(3 PER SIDE)
BALL STUDS
(3 PER SIDE)
23