FLUE LENGTHS
Length supplied in standard kit - horizontal
815mm
Max horizontal length
(from boiler to chimney - 60/100mm)
2000mm
Min horizontal length
(from boiler to chimney - 60/100mm)
100mm
Max vertical length
(from boiler to chimney - 60/100mm)
2000mm
Min vertical length
(from boiler to chimney - 60/100mm)
200mm
Length supplied in standard kit - vertical
(available in 10m, 20m and 30m length)
N/A
FLEXITUBE MUST BE PURCHASED AS AN ACCESSORY TO COMPLETE THE KIT
(See below)
Flexi tube min length
5m
Flexi tube max length
30m
ACCESSORIES
Description
Part No.
Resistive Length
HORIZONTAL - 60/100 Accessories
Flue extension duct - 500mm
956092
450mm
Flue extension duct - 1000mm (Incl. 1 x support bracket)
956093
950mm
93° extension elbow
956091
1550mm
45° extension elbow (pair)
956090
775mm
Air inlet duct - included in kit
N/A
N/A
Straight adapter (60/80) - included in kit
N/A
N/A
91.5° adapter elbow (80/80) - included in kit
N/A
N/A
Support bracket - 100mm
840517
N/A
93° flanged elbow - included in kit
956082
N/A
Vertical turret socket
956087
N/A
VERTICAL - Accessories
Flexi tube - 10m
956110
10m
Flexi tube - 20m
956111
20m
Flexi tube - 30m
956112
30m
Straight duct (80) - included in kit
N/A
N/A
Chimney terminal - included in kit
N/A
N/A
NOTE: RESISTIVE LENGTH INFORMATION ONLY REQUIRED FOR COAXIAL FLUE PARTS. THE CORRUGATED (FLEXI TUBE)
FLUE PARTS ARE FIXED AND ALL PARTS ARE REQUIRED FOR EVERY APPLICATION.