DUAL DRYER SYSTEM
INSTALLATION/SERVICE
MANUAL (L31279)
®
Outlet Check Valve Assembly
1. Ensure air pressure is at 0 PSI in air system.
2. Remove control manifold to access outlet
check valve plugs.
3. Clean and remove all debris from around the
check valve.
4. Remove check valve from dryer base.
5. Inspect and clean check valve bore as necessary.
6. Retrieve new check valve and grease o-rings.
7. Install new check valve. Tighten to 84-94 in-lbs
(9.5-10.5 Nm).
8. Reinstall control manifold. Apply a small amount
of silicone grease to green part of banjo bolt seals.
Tighten M12 banjo bolts to 130-150 in-lbs
(15-17 Nm).
Turbo-Protection Valve (TPV)
1. Disconnect air line from Consep manifold to
dryer manifold.
2. Disconnect air line from GeminiMDx to system
tanks.
3. Remove outlet manifold and control manifold for
access to turbo-protection valve fitting.
4. Clean and remove all debris around fitting.
5. Loosen and remove fitting from dryer base.
6. Ensure threads and fitting bore are free of debris.
Removal/Installation Instructions (cont’d)
Page 21