DUAL DRYER SYSTEM
INSTALLATION/SERVICE
MANUAL (L31279)
®
Turbo-Protection Valve (TPV) (cont’d)
7. Retrieve new TPV and grease o-ring.
8. Install TPV in dryer base and tighten to
45-55 ft-lbs (61-75 Nm).
9. Reinstall control manifold and outlet manifold.
Apply a small amount of silicone grease to green
part of banjo bolts seals.
Tighten banjo bolt(s) to:
M22 45-55 ft-lbs (61-75 Nm)
M12 130-150 in-lbs (15-17 Nm)
10. Reconnect air line from system tanks to
GeminiMDx.
11. Reconnect air line from dryer manifold to
Consep manifold.
Removal/Installation Instructions (cont’d)
Page 22
Safety Valve
1. Ensure air pressure is at 0 PSI in air system.
2. Clean and remove all debris from around
safety valve.
3. Remove safety valve from dryer base.
4. Inspect and clean safety valve bore as necessary.
5. Reinstall
safety valve.