4. INITIAL SETUP (continued)

Display

Power switch

PVC
PE
PA
PVDF
ETFE
SI
PTFE

Material

Output value (%)

10
10
20
30
40
45
55

1. Switch on the power.
2.            will be lit for 2 sec.
3. The displayed output value will 

blink. After the temperature has 

increased and stabilized,  

the displayed value will change from 

blinking to lit. The unit is ready for 

use when the displayed value is lit.

* For the output value, set it according 

to the following wire material 

indication table.

ENTER

Increase the 

displayed value.

Decrease the 

displayed value.

Pressing the button 

for a long time 

enters the mode for 

changing the output 

value. 

Finalizes setting of 

the data input value 

and ends the data 

input mode.

 NOTE 

Output values will vary from the values in the 

table above depending on the wire composition 

and wire diameter. In addition, it may be 

necessary to set higher values depending on 

blade oxidation and maintenance conditions.

 CAUTION

• The factory default value is set to 50%.

• Since the blades will become hot, place the 

handle on the handle holder when it is not

 

being used.

5-1 Operation and display (switch and operation buttons)

5-2 Setting/changing output

4-2 Station

1. Connect the power cord to the inlet on the 

rear side of the station.

2. Place the HAKKO FT-8004 on the handle holder 

with the blades facing up.

3. Plug the handle plug into the receptacle.
4. Plug the power cord plug into an electrical outlet.

Handle holder

plug

Receptacle

5.  HOW TO USE 

Example: When changing the output from 50% to 65%:

Temperature is stabilized

Press the         button 3 

times and press 

the [

ENTER

] button.

1. Press the      ,       or [

ENTER

] button for 2 sec 

or longer.

  The unit will enter the output change mode and 

the displayed value will change to blinking.

2. Press the       or       button to finalize setting of 

value.

  After your desired value is displayed, press  

the [

ENTER

] button. When the displayed value 

will change from blinking to lit, the unit is ready 

for use.

Summary of Contents for FT-8003

Page 1: ...r purchasing the HAKKO FT 802 Thermal Wire Stripper Be sure to read this manual before operating the HAKKO FT 802 Keep this manual readily accessible for reference Instruction Manual THERMAL WIRE STRI...

Page 2: ...NAMES 1 2 SPECIFICATIONS 1 3 WARNINGS CAUTIONS AND NOTES 2 4 INITIAL SETUP 3 4 1 Blades 3 4 1 1 Attaching blades 3 4 1 2 Removing blades 3 4 1 3 Blade holder 3 4 2 Station 4 5 HOW TO USE 4 5 1 Operati...

Page 3: ...wer Consumption 76 W HAKKO FT 802 Power Consumption Length of Cord Length w o cord blade Weight w o cord blade 72 W 20 V 1 6 m 5 2 ft 153 mm 6 0 in 47 g 0 10 lb Handle HAKKO FT 8004 Output Outside dim...

Page 4: ...on the handle holder when not using the HAKKO FT 802 The unit is for a counter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physica...

Page 5: ...xagon socket set screw M2 5 2 5 V groove 1 Switch off the power and wait until the blades have cooled down 2 Remove the screws with the hexagonal wrench and remove the blades using the main body blade...

Page 6: ...s depending on blade oxidation and maintenance conditions CAUTION The factory default value is set to 50 Since the blades will become hot place the handle on the handle holder when it is not being use...

Page 7: ...l with the blade surface The lead adjuster can be removed with the handle cover attached to the handle 5 3 Handle 5 3 1 Attaching the lead adjuster NOTE The output value range is 5 to 100 The output v...

Page 8: ...5 mm 1 to 35 mm Adjuster plate 5 HOW TO USE continued 1 Align the wire end with the lead adjuster 2 Pinch the wire with the blades according to the diameter of the wire to be stripped The pinched area...

Page 9: ...sumption Auto shutoff enable disable setting The auto shut off function can be enabled or disabled Auto shutoff time setting After the set time has elapsed the output will be switched off and the unit...

Page 10: ...ped to the parameter number selection screen again NOTE 2 Select the parameter number Initially the parameter number will be blinking Change the parameter number to the parameter to be set by pressing...

Page 11: ...ress the button three times to change to the password input screen Press the ENTER button Press the ENTER button Press the button three times Press the ENTER button Press the ENTER button Press the EN...

Page 12: ...to sleep function The auto sleep function saves the set output by approx 50 reducing the blade temperature and power consumption This function extends the service life of blades When the auto sleep fu...

Page 13: ...Auto sleep is set to 10 min and auto shutoff is 20 min When the handle is placed on the handle holder Time until auto sleep starts In sleep mode Auto shutoff Display is lit to The auto sleep time can...

Page 14: ...normal value is 3 5 10 If the measured resistance value is abnormal replace the blade with a new one Measure the resistance of this section of the heating element Attach normal blades whose resistanc...

Page 15: ...ce the fuse with a new one If the replaced fuse blows again please request repair Insert the blade fully to the end Refer to the items in disconnection of connection cord and blowing of heating elemen...

Page 16: ...cord 3 core American plug Power cord 3 core SI plug Power cord 3 core BR plug Fuse 250 V 2 A Fuse 250 V 1 A Specifications for HAKKO FT 802 120 V USA India 220 V KC 230 V CE 230 V CE U K China Taiwan...