background image

10

High output setting

Enable or disable the high output function.

This function operates when the password setting mode is set to            (partially enabled) or             

(enabled).

When the high output function is enabled, it is possible to set higher values than usual in “            Output 

upper limit setting”.

When the high output function is enabled, the maximum settable upper limit value and the maximum 

parameter “            Output upper limit setting” will be 

120

.  (When the function is disabled, the maximum 

value for both is 

100

.) 

Output upper limit setting

An upper limit for the blade output value can be set, making it impossible to set the value to higher than 

the upper limit.

This function operates when the password setting mode is set to             (partially enabled) or             

(enabled).

If the set parameter value is 

   

, the maximum settable output value will be 

80

. It is possible to set  

the values in increments of 5%.

(The initially set value is 100%.)

Auto sleep enable/disable setting

Enable or disable the auto sleep function.

The auto sleep function saves the set output by approx. 50%, reducing the blade temperature and power 

consumption.This function extends the service life of blades. 

When the auto sleep function is enabled, the auto sleep function will operate when the specified time has 

elapsed after placing the handle on the handle holder.

The time until the auto sleep function operates can be set in

 

“             Auto sleep time setting”.

: High output function is disabled.
: High output function is enabled.

: Auto-sleep is disabled.
: Auto-sleep is enabled.

In order to achieve high values 

105

 or more for the settable value, parameter “            High output 

setting” should be changed to             , then parameter “            Output upper limit setting” must 

also be changed before changing  the settable value.

When setting the output setting to 

85

 or more, regardless of the ON/OFF setting of the auto sleep 

function, placing the handle on the handle holder will activate the auto sleep function.

NOTE

NOTE

6. SETTING PARAMETERS (continued)

 WARNING

The high temperature at 105% to 120% could shorten blade life or that the blade will glow red.

Place the handle on the handle holder when not using the HAKKO FT-802.

Summary of Contents for FT-8003

Page 1: ...r purchasing the HAKKO FT 802 Thermal Wire Stripper Be sure to read this manual before operating the HAKKO FT 802 Keep this manual readily accessible for reference Instruction Manual THERMAL WIRE STRI...

Page 2: ...NAMES 1 2 SPECIFICATIONS 1 3 WARNINGS CAUTIONS AND NOTES 2 4 INITIAL SETUP 3 4 1 Blades 3 4 1 1 Attaching blades 3 4 1 2 Removing blades 3 4 1 3 Blade holder 3 4 2 Station 4 5 HOW TO USE 4 5 1 Operati...

Page 3: ...wer Consumption 76 W HAKKO FT 802 Power Consumption Length of Cord Length w o cord blade Weight w o cord blade 72 W 20 V 1 6 m 5 2 ft 153 mm 6 0 in 47 g 0 10 lb Handle HAKKO FT 8004 Output Outside dim...

Page 4: ...on the handle holder when not using the HAKKO FT 802 The unit is for a counter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physica...

Page 5: ...xagon socket set screw M2 5 2 5 V groove 1 Switch off the power and wait until the blades have cooled down 2 Remove the screws with the hexagonal wrench and remove the blades using the main body blade...

Page 6: ...s depending on blade oxidation and maintenance conditions CAUTION The factory default value is set to 50 Since the blades will become hot place the handle on the handle holder when it is not being use...

Page 7: ...l with the blade surface The lead adjuster can be removed with the handle cover attached to the handle 5 3 Handle 5 3 1 Attaching the lead adjuster NOTE The output value range is 5 to 100 The output v...

Page 8: ...5 mm 1 to 35 mm Adjuster plate 5 HOW TO USE continued 1 Align the wire end with the lead adjuster 2 Pinch the wire with the blades according to the diameter of the wire to be stripped The pinched area...

Page 9: ...sumption Auto shutoff enable disable setting The auto shut off function can be enabled or disabled Auto shutoff time setting After the set time has elapsed the output will be switched off and the unit...

Page 10: ...ped to the parameter number selection screen again NOTE 2 Select the parameter number Initially the parameter number will be blinking Change the parameter number to the parameter to be set by pressing...

Page 11: ...ress the button three times to change to the password input screen Press the ENTER button Press the ENTER button Press the button three times Press the ENTER button Press the ENTER button Press the EN...

Page 12: ...to sleep function The auto sleep function saves the set output by approx 50 reducing the blade temperature and power consumption This function extends the service life of blades When the auto sleep fu...

Page 13: ...Auto sleep is set to 10 min and auto shutoff is 20 min When the handle is placed on the handle holder Time until auto sleep starts In sleep mode Auto shutoff Display is lit to The auto sleep time can...

Page 14: ...normal value is 3 5 10 If the measured resistance value is abnormal replace the blade with a new one Measure the resistance of this section of the heating element Attach normal blades whose resistanc...

Page 15: ...ce the fuse with a new one If the replaced fuse blows again please request repair Insert the blade fully to the end Refer to the items in disconnection of connection cord and blowing of heating elemen...

Page 16: ...cord 3 core American plug Power cord 3 core SI plug Power cord 3 core BR plug Fuse 250 V 2 A Fuse 250 V 1 A Specifications for HAKKO FT 802 120 V USA India 220 V KC 230 V CE 230 V CE U K China Taiwan...

Reviews: