background image

12

7. 

MAINTENANCE

Although blades are designed to resist oxidation, if oxidation of  

the blades occurs and prevents you to do wire-stripping work 

smoothly, use a wire brush lightly on the blade to remove the oxide.

Applying a wire brush strongly may damage the blades, resulting in 

reduced service life. Therefore, do not brush blades excessively.

Leaving the unit in a no-load condition for a long time with the blade 

heated highly may cause the surface to be oxidized, resulting in 

reduced service life of blades due to overload applied to the heating 

element.

Be sure to enable auto sleep and place the handle on the handle holder 

when not using it.

Be sure to switch off the power switch if the unit will not be used for a 

long time.

About blades
1. Maintenance

2. Suspension during use

1. Blown heating element

2. How to check whether the 

connection cord is 

connected or disconnected

3. How to replace the fuse

Check that no electrical abnormality occurs in the heating element. 

Measure the resistance at normal temperature (15 to 25℃/59 to 77℉

).

The normal value is 3.5 Ω ±10

 If the measured resistance value is 

abnormal, replace the blade with a new one.

Measure the resistance of this section of the heating element.

Attach normal blades (whose resistance value of heating elements is 

normal) to both handles and measure the resistance value between 

the connector pins.

Resistance between Pin 1 and Pin 5: 6.2 Ω to 8.0 Ω

If the resistance value is outside the above value range, replace  

the HAKKO FT-8004 with a new one.

1. Unplug the power cord from the inlet.
2. Pull out the fuse holder.
3. Replace the current fuse with a new one.

4. Reassemble the fuse holder to its original condition.

1

5

 WARNING

Unless otherwise specified, be sure to switch off the power and unplug the power plug when 

performing the following procedures.

The unit should be maintained periodically to be able to use it in proper condition for a long 

time. Since the degree of consumption of the unit varies depending on the use temperature, 

etc., perform maintenance of the unit according to use conditions.

 WARNING

Since the unit can reach a very high temperature, please work carefully. Except for special 

cases, always turn the power switch OFF and disconnect the power plug before performing any 

maintenance procedure.

8. 

INSPECTION

Summary of Contents for FT-8003

Page 1: ...r purchasing the HAKKO FT 802 Thermal Wire Stripper Be sure to read this manual before operating the HAKKO FT 802 Keep this manual readily accessible for reference Instruction Manual THERMAL WIRE STRI...

Page 2: ...NAMES 1 2 SPECIFICATIONS 1 3 WARNINGS CAUTIONS AND NOTES 2 4 INITIAL SETUP 3 4 1 Blades 3 4 1 1 Attaching blades 3 4 1 2 Removing blades 3 4 1 3 Blade holder 3 4 2 Station 4 5 HOW TO USE 4 5 1 Operati...

Page 3: ...wer Consumption 76 W HAKKO FT 802 Power Consumption Length of Cord Length w o cord blade Weight w o cord blade 72 W 20 V 1 6 m 5 2 ft 153 mm 6 0 in 47 g 0 10 lb Handle HAKKO FT 8004 Output Outside dim...

Page 4: ...on the handle holder when not using the HAKKO FT 802 The unit is for a counter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physica...

Page 5: ...xagon socket set screw M2 5 2 5 V groove 1 Switch off the power and wait until the blades have cooled down 2 Remove the screws with the hexagonal wrench and remove the blades using the main body blade...

Page 6: ...s depending on blade oxidation and maintenance conditions CAUTION The factory default value is set to 50 Since the blades will become hot place the handle on the handle holder when it is not being use...

Page 7: ...l with the blade surface The lead adjuster can be removed with the handle cover attached to the handle 5 3 Handle 5 3 1 Attaching the lead adjuster NOTE The output value range is 5 to 100 The output v...

Page 8: ...5 mm 1 to 35 mm Adjuster plate 5 HOW TO USE continued 1 Align the wire end with the lead adjuster 2 Pinch the wire with the blades according to the diameter of the wire to be stripped The pinched area...

Page 9: ...sumption Auto shutoff enable disable setting The auto shut off function can be enabled or disabled Auto shutoff time setting After the set time has elapsed the output will be switched off and the unit...

Page 10: ...ped to the parameter number selection screen again NOTE 2 Select the parameter number Initially the parameter number will be blinking Change the parameter number to the parameter to be set by pressing...

Page 11: ...ress the button three times to change to the password input screen Press the ENTER button Press the ENTER button Press the button three times Press the ENTER button Press the ENTER button Press the EN...

Page 12: ...to sleep function The auto sleep function saves the set output by approx 50 reducing the blade temperature and power consumption This function extends the service life of blades When the auto sleep fu...

Page 13: ...Auto sleep is set to 10 min and auto shutoff is 20 min When the handle is placed on the handle holder Time until auto sleep starts In sleep mode Auto shutoff Display is lit to The auto sleep time can...

Page 14: ...normal value is 3 5 10 If the measured resistance value is abnormal replace the blade with a new one Measure the resistance of this section of the heating element Attach normal blades whose resistanc...

Page 15: ...ce the fuse with a new one If the replaced fuse blows again please request repair Insert the blade fully to the end Refer to the items in disconnection of connection cord and blowing of heating elemen...

Page 16: ...cord 3 core American plug Power cord 3 core SI plug Power cord 3 core BR plug Fuse 250 V 2 A Fuse 250 V 1 A Specifications for HAKKO FT 802 120 V USA India 220 V KC 230 V CE 230 V CE U K China Taiwan...

Reviews: