background image

11

10 min.

20 min.

0

Auto shutoff enable/disable setting

Enable or disable the auto shutoff function.

When the auto shutoff function is enabled, the auto shutoff function will operate when the specified time 

has elapsed after the unit entered auto sleep after placing the handle on the handle holder.

The time until the auto shutoff function operates can be set in “             Auto shutoff time setting”.

: Auto shutoff is disabled.
: Auto shutoff is enabled.

Auto shutoff time setting

This function operates when the Auto shutoff enable/disable setting is set to            (enabled).

When the set time has elapsed without action after placing the handle on the handle holder, the auto 

shutoff function will operate. The output will become zero and the unit will enter standby mode.
Display:            is lit.
 

 to 

: Auto shutoff is enabled. (The set time shows the time when the auto shutoff function will 

operate after sleeping.)

 

 

  The auto shutoff time can be set in increments of 1 min. (The initial default set time is  

15 min. and the maximum time is 30 min.)

Example: Auto sleep is set to 10 min. and auto shutoff is 20 min.

When the handle is 

placed on the handle holder

Time until auto

sleep starts

In sleep mode

Auto shutoff

Display:             is lit.
           to           : The auto sleep time can be set in increments of 1 min. 

 

(The initial default set time is 15 min. and the maximum time is 30 min.)

Auto sleep time setting

This function operates when the Auto sleep enable/disable setting is set to            (enabled). Set the time 

until the auto sleep function operates after placing the handle on the handle holder. When the time is set 

to           , the auto sleep function starts immediately after placing the handle on the handle holder.

The auto sleep function does not work when the handle is not placed on the handle holder. When 

the auto sleep function is operating, the unit will become active again when the handle is lifted off 

of the handle holder.

NOTE

 CAUTION

Do not leave the unit in the auto shutoff mode for a long time. If the unit will not be used for a long 

time, be sure to switch off the power.

 NOTE 

The auto shutoff function does not work when the handle is not placed on the handle holder.

If the auto shutoff function operates, switch the power off once and then switch it back on to start 

using the unit again.

Summary of Contents for FT-8003

Page 1: ...r purchasing the HAKKO FT 802 Thermal Wire Stripper Be sure to read this manual before operating the HAKKO FT 802 Keep this manual readily accessible for reference Instruction Manual THERMAL WIRE STRI...

Page 2: ...NAMES 1 2 SPECIFICATIONS 1 3 WARNINGS CAUTIONS AND NOTES 2 4 INITIAL SETUP 3 4 1 Blades 3 4 1 1 Attaching blades 3 4 1 2 Removing blades 3 4 1 3 Blade holder 3 4 2 Station 4 5 HOW TO USE 4 5 1 Operati...

Page 3: ...wer Consumption 76 W HAKKO FT 802 Power Consumption Length of Cord Length w o cord blade Weight w o cord blade 72 W 20 V 1 6 m 5 2 ft 153 mm 6 0 in 47 g 0 10 lb Handle HAKKO FT 8004 Output Outside dim...

Page 4: ...on the handle holder when not using the HAKKO FT 802 The unit is for a counter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physica...

Page 5: ...xagon socket set screw M2 5 2 5 V groove 1 Switch off the power and wait until the blades have cooled down 2 Remove the screws with the hexagonal wrench and remove the blades using the main body blade...

Page 6: ...s depending on blade oxidation and maintenance conditions CAUTION The factory default value is set to 50 Since the blades will become hot place the handle on the handle holder when it is not being use...

Page 7: ...l with the blade surface The lead adjuster can be removed with the handle cover attached to the handle 5 3 Handle 5 3 1 Attaching the lead adjuster NOTE The output value range is 5 to 100 The output v...

Page 8: ...5 mm 1 to 35 mm Adjuster plate 5 HOW TO USE continued 1 Align the wire end with the lead adjuster 2 Pinch the wire with the blades according to the diameter of the wire to be stripped The pinched area...

Page 9: ...sumption Auto shutoff enable disable setting The auto shut off function can be enabled or disabled Auto shutoff time setting After the set time has elapsed the output will be switched off and the unit...

Page 10: ...ped to the parameter number selection screen again NOTE 2 Select the parameter number Initially the parameter number will be blinking Change the parameter number to the parameter to be set by pressing...

Page 11: ...ress the button three times to change to the password input screen Press the ENTER button Press the ENTER button Press the button three times Press the ENTER button Press the ENTER button Press the EN...

Page 12: ...to sleep function The auto sleep function saves the set output by approx 50 reducing the blade temperature and power consumption This function extends the service life of blades When the auto sleep fu...

Page 13: ...Auto sleep is set to 10 min and auto shutoff is 20 min When the handle is placed on the handle holder Time until auto sleep starts In sleep mode Auto shutoff Display is lit to The auto sleep time can...

Page 14: ...normal value is 3 5 10 If the measured resistance value is abnormal replace the blade with a new one Measure the resistance of this section of the heating element Attach normal blades whose resistanc...

Page 15: ...ce the fuse with a new one If the replaced fuse blows again please request repair Insert the blade fully to the end Refer to the items in disconnection of connection cord and blowing of heating elemen...

Page 16: ...cord 3 core American plug Power cord 3 core SI plug Power cord 3 core BR plug Fuse 250 V 2 A Fuse 250 V 1 A Specifications for HAKKO FT 802 120 V USA India 220 V KC 230 V CE 230 V CE U K China Taiwan...

Reviews: