background image

3

4. 

INITIAL SETUP

1. Insert the blades fully and match the 

V-groove on the blades to the V-groove 

on the mounting flange.  Push until blades 

are flush with mounting flange.

2. Insert the hexagon socket set screws but do 

not tighten.

 NOTE 

Blades will not heat up unless both blades are 

fully inserted.  Be sure to use the blades as a set. 

3. Adjust and align the blades manually then 

tighten the hexagon socket set screws with 

the hexagon wrench to secure the blades.

Hexagon wrench

Hexagon socket set screw 

(M2.5 × 2.5)

V-groove

1. Switch off the power and wait until the blades 

have cooled down.

2. Remove the screws with the hexagonal 

wrench and remove the blades using the main 

body blade removal plate.

 CAUTION

• When pulling out or inserting blades, be sure 

that the power is switched off.

• Before pulling out the blades, check that the 

blades have cooled down sufficiently.

4-1-3 Blade holder

The removed blades can be placed in the holder 

as shown at right.

Hex wrench can placed in the position of the 

arrow.

 NOTE 

Place the removed blade in the blade holder.

4-1 Blades

4-1-1 Attaching blades

4-1-2 Removing blades

Blade removal plate

Blade removal plate

Blade guard

Summary of Contents for FT-8003

Page 1: ...r purchasing the HAKKO FT 802 Thermal Wire Stripper Be sure to read this manual before operating the HAKKO FT 802 Keep this manual readily accessible for reference Instruction Manual THERMAL WIRE STRI...

Page 2: ...NAMES 1 2 SPECIFICATIONS 1 3 WARNINGS CAUTIONS AND NOTES 2 4 INITIAL SETUP 3 4 1 Blades 3 4 1 1 Attaching blades 3 4 1 2 Removing blades 3 4 1 3 Blade holder 3 4 2 Station 4 5 HOW TO USE 4 5 1 Operati...

Page 3: ...wer Consumption 76 W HAKKO FT 802 Power Consumption Length of Cord Length w o cord blade Weight w o cord blade 72 W 20 V 1 6 m 5 2 ft 153 mm 6 0 in 47 g 0 10 lb Handle HAKKO FT 8004 Output Outside dim...

Page 4: ...on the handle holder when not using the HAKKO FT 802 The unit is for a counter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physica...

Page 5: ...xagon socket set screw M2 5 2 5 V groove 1 Switch off the power and wait until the blades have cooled down 2 Remove the screws with the hexagonal wrench and remove the blades using the main body blade...

Page 6: ...s depending on blade oxidation and maintenance conditions CAUTION The factory default value is set to 50 Since the blades will become hot place the handle on the handle holder when it is not being use...

Page 7: ...l with the blade surface The lead adjuster can be removed with the handle cover attached to the handle 5 3 Handle 5 3 1 Attaching the lead adjuster NOTE The output value range is 5 to 100 The output v...

Page 8: ...5 mm 1 to 35 mm Adjuster plate 5 HOW TO USE continued 1 Align the wire end with the lead adjuster 2 Pinch the wire with the blades according to the diameter of the wire to be stripped The pinched area...

Page 9: ...sumption Auto shutoff enable disable setting The auto shut off function can be enabled or disabled Auto shutoff time setting After the set time has elapsed the output will be switched off and the unit...

Page 10: ...ped to the parameter number selection screen again NOTE 2 Select the parameter number Initially the parameter number will be blinking Change the parameter number to the parameter to be set by pressing...

Page 11: ...ress the button three times to change to the password input screen Press the ENTER button Press the ENTER button Press the button three times Press the ENTER button Press the ENTER button Press the EN...

Page 12: ...to sleep function The auto sleep function saves the set output by approx 50 reducing the blade temperature and power consumption This function extends the service life of blades When the auto sleep fu...

Page 13: ...Auto sleep is set to 10 min and auto shutoff is 20 min When the handle is placed on the handle holder Time until auto sleep starts In sleep mode Auto shutoff Display is lit to The auto sleep time can...

Page 14: ...normal value is 3 5 10 If the measured resistance value is abnormal replace the blade with a new one Measure the resistance of this section of the heating element Attach normal blades whose resistanc...

Page 15: ...ce the fuse with a new one If the replaced fuse blows again please request repair Insert the blade fully to the end Refer to the items in disconnection of connection cord and blowing of heating elemen...

Page 16: ...cord 3 core American plug Power cord 3 core SI plug Power cord 3 core BR plug Fuse 250 V 2 A Fuse 250 V 1 A Specifications for HAKKO FT 802 120 V USA India 220 V KC 230 V CE 230 V CE U K China Taiwan...