background image

1

2

3

4

AWG 26

AWG 30

AWG 36

AWG 38

AWG 32
AWG 28

AWG 28
AWG 24
AWG 20

AWG 18

AWG 22

AWG 26

Part name

Wire stripper blade/Straight
Wire stripper blade/18-28AWG
Wire stripper blade/26-38AWG
Hexagon socket set screw/M2.5 × 2.5

Specifications

qty 2

Blade

Item No.

1
2
3
4

Part No.

G4-1601
G4-1602
G4-1603
B5260

1

2

3

4

SEMS screw

M3×6 P2

SEMS screw

M3×18 P2 (2)

Station

Part No.

B5244

B5245

B2419

B2421

B2422

B2424

B2425

B2426

B2436

B3508

B3550

B3616

B3011

B2987

Item No.

1

2

3

4

Part name

Blade removal plate w/screw

Handpiece holder w/screw qty 2

Power cord/3 core & American plug

Power cord/3 cored wire with no plug

Power cord/3 core & BS plug

Power cord/3 core & European plug

Power cord/3 core & BS plug

Power cord/3 core & Australian plug

Power cord/3 core & Chinese plug

Power cord/3 core & American plug

Power cord/3 core & SI plug

Power cord/3 core & BR plug

Fuse/250 V-2 A

Fuse/250 V-1 A

Specifications

for HAKKO FT-802

120 V USA

India

220 V KC, 230 V CE

230 V CE U.K.

China

Taiwan, Philippines, Thailand, Vietnam

100 - 127 V

220 - 240 V

10. PART NUMBER (continued)

2022.6

MA02992XZ220623

© 2018-2022 HAKKO Corporation. All Rights Reserved.

OVERSEAS AFFILIATES

U.S.A.: AMERICAN HAKKO PRODUCTS, INC.

TEL: (661) 294-0090 FAX: (661) 294-0096

Toll Free (800) 88-HAKKO   

                                   4   2   5   5   6

https://www.HakkoUSA.com  E-mail: [email protected] 

SINGAPORE: HAKKO PRODUCTS PTE., LTD.

TEL: 6748-2277 FAX: 6744-0033

https://www.hakko.com.sg     E-mail: [email protected]

HONG KONG: HAKKO DEVELOPMENT CO., LTD.

TEL: 2811-5588 FAX: 2590-0217

https://www.hakko.com.cn     E-mail: [email protected]

Please access the web address below for other distributors.

https://www.hakko.com

HEAD OFFICE

4-5, Shiokusa 2-chome, Naniwa-ku, Osaka 556-0024 JAPAN

TEL: +81-6-6561-3225 FAX: +81-6-6561-8466

https://www.hakko.com  E-mail: [email protected]  

Summary of Contents for FT-8003

Page 1: ...r purchasing the HAKKO FT 802 Thermal Wire Stripper Be sure to read this manual before operating the HAKKO FT 802 Keep this manual readily accessible for reference Instruction Manual THERMAL WIRE STRI...

Page 2: ...NAMES 1 2 SPECIFICATIONS 1 3 WARNINGS CAUTIONS AND NOTES 2 4 INITIAL SETUP 3 4 1 Blades 3 4 1 1 Attaching blades 3 4 1 2 Removing blades 3 4 1 3 Blade holder 3 4 2 Station 4 5 HOW TO USE 4 5 1 Operati...

Page 3: ...wer Consumption 76 W HAKKO FT 802 Power Consumption Length of Cord Length w o cord blade Weight w o cord blade 72 W 20 V 1 6 m 5 2 ft 153 mm 6 0 in 47 g 0 10 lb Handle HAKKO FT 8004 Output Outside dim...

Page 4: ...on the handle holder when not using the HAKKO FT 802 The unit is for a counter or workbench use only This appliance can be used by children aged from 8 years and above and persons with reduced physica...

Page 5: ...xagon socket set screw M2 5 2 5 V groove 1 Switch off the power and wait until the blades have cooled down 2 Remove the screws with the hexagonal wrench and remove the blades using the main body blade...

Page 6: ...s depending on blade oxidation and maintenance conditions CAUTION The factory default value is set to 50 Since the blades will become hot place the handle on the handle holder when it is not being use...

Page 7: ...l with the blade surface The lead adjuster can be removed with the handle cover attached to the handle 5 3 Handle 5 3 1 Attaching the lead adjuster NOTE The output value range is 5 to 100 The output v...

Page 8: ...5 mm 1 to 35 mm Adjuster plate 5 HOW TO USE continued 1 Align the wire end with the lead adjuster 2 Pinch the wire with the blades according to the diameter of the wire to be stripped The pinched area...

Page 9: ...sumption Auto shutoff enable disable setting The auto shut off function can be enabled or disabled Auto shutoff time setting After the set time has elapsed the output will be switched off and the unit...

Page 10: ...ped to the parameter number selection screen again NOTE 2 Select the parameter number Initially the parameter number will be blinking Change the parameter number to the parameter to be set by pressing...

Page 11: ...ress the button three times to change to the password input screen Press the ENTER button Press the ENTER button Press the button three times Press the ENTER button Press the ENTER button Press the EN...

Page 12: ...to sleep function The auto sleep function saves the set output by approx 50 reducing the blade temperature and power consumption This function extends the service life of blades When the auto sleep fu...

Page 13: ...Auto sleep is set to 10 min and auto shutoff is 20 min When the handle is placed on the handle holder Time until auto sleep starts In sleep mode Auto shutoff Display is lit to The auto sleep time can...

Page 14: ...normal value is 3 5 10 If the measured resistance value is abnormal replace the blade with a new one Measure the resistance of this section of the heating element Attach normal blades whose resistanc...

Page 15: ...ce the fuse with a new one If the replaced fuse blows again please request repair Insert the blade fully to the end Refer to the items in disconnection of connection cord and blowing of heating elemen...

Page 16: ...cord 3 core American plug Power cord 3 core SI plug Power cord 3 core BR plug Fuse 250 V 2 A Fuse 250 V 1 A Specifications for HAKKO FT 802 120 V USA India 220 V KC 230 V CE 230 V CE U K China Taiwan...