7
B. The preset mode (Select the set temperature)
When changing the soldering iron temperature, there is a preset function that selects the temperatures set
(up to 5 can be stored).
Initial preset temperatures
P1: 250℃ (482℉), P2: 300℃ (572℉), P3: 350℃ (662℉), P4: 400℃ (752℉), P5: 450℃ (842℉)
The initial number of active presets is set to 5 at the factory.
The default selected preset is set to P3 at the factory.
Example : Changing preset temperature from preset No.1 (250℃) to No.3 (350℃).
The procedure for making changes to the preset temperatures is the same with “A. The temperature
setting mode” in 6. OPERATION (Soldering iron).
Change the mode on the parameter setting screen. (Refer to “7. Parameter Setting (Soldering Iron)”)
*Preset selection screen
Be displayed
alternately.
Press the button
twice.
Be displayed
alternately.
Press the button
once.
Press the button
once.
Heater control will begin with new
preset temperature.
CAUTION
C. The adjust mode (Performing the temperature adjustment)
When replacing the iron, heater or tip, a temperature adjustment may be required.
Use the adjust mode to perform the temperature adjustment.
• Enter the observed value in the adjust mode after the tip temperature stabilizes.
• The maximum single adjustment that can be made is ±150℃ (270℉) relative to the set temperature.
If a larger adjustment is needed, make the first adjustment at the maximum value of 150℃ (270℉),
then repeat the adjustment process.
Example : If the measured temperature is 380℃ and the set temperature is 400℃.
1. Press and hold the button for at least two seconds.
●
is displayed.
When you press the button, the display will move
to the adjust mode.
2. Changing from to .
●
The procedure for changing the value in adjust mode
is the same
with “A. The temperature setting mode”
in 6. OPERATION (Soldering iron).
3. Press the button to exit the setting after changing
the values.
●
The tip temperature will be adjusted accordingly.
CAUTION
* How to distinguish between
Temperature Setting Mode and Adjust Mode.
The display differs in the temperature setting
and the adjust mode.
I
n the Temperature
Setting Mode
In the Adjust Mode
Identification lamps are on
in the adjust mode.
Please be sure to confirm the status of the
identification lamps so that you do not enter
a value in the wrong mode.
NOTE :
During adjust mode, the hundreds digit will
accept values from 0 through 6 if the temperature
is set to display in ℃, or the values 0 through 9
if the temperature is set to display in ℉.
6. OPERATION (Soldering iron) (continued)
8
D. Password function (Restriction on setting changes)
It is possible to restrict certain setting changes to the unit.
There are three choices for the password setting. (The factory default is "0 : Open")
○
: You can make changes without entering a password.
△
: You can choose whether or not a password is needed to make changes.
×
: A password is required to make changes.
0 : Open
○
○
○
○
1 : Partial
×
△
△
△
2 : Restricted
×
×
×
×
Move to the parameter setting mode
Move to the temperature setting mode
Move to the preset mode
Move to the adjust mode
The letters
for password
Example: The procedure for changing the set temperature when the unit is restricted by a password.
(Password is “AbC”)
Select and input three letters for password
from six letters on the right.
The unit will move to the change setting screen for each mode after entering the password.
Please change the setting for each mode according to the procedure.
Enter the parameter setting to change the mode.
Please refer to “7. PARAMETER SETTING (Soldering iron)”.
Press the button
once.
Press the button
once.
Press and hold the
button for at
least one second.
Press the button
twice.
Press the button
three times.
Press the button
once.
Press the button
once.
CAUTION
• If the password you entered is incorrect, the display will
show three dashes for you to re-enter the password.
• If you enter the password incorrectly twice in a row, the
display will return to the previous screen.