![background image](http://html1.mh-extra.com/html/hakko-electronics/fr-701/fr-701_instruction-manual_3297643045.webp)
17. ERROR MESSAGE (Desoldering Tool)
●
Sensor Error
●
Grip Error
●
Low Temp Error
●
Heater Short Error
●
FATAL Error
EXAMPLE:
350
℃
(400
℃
- 50
℃
)
OR
650
℉
(750
℉
-
100
℉
)
Set temperature
Set temperature
Low-temperature alarm tolerance
Low-temperature alarm tolerance
EXAMPLE:
Assume that the temperature setting is 400℃/750℉ and the
tolerance 50℃/100℉. If the temperature continues to decrease
and finally falls below the value indicated while the heating
element is on, "Low Temp Error" is displayed.
When there is the possibility that a failure has occurred in the
sensor or heater (including the sensor circuit), "
Sensor Error" is
displayed and the power is shut down.
"Grip Error
" will be displayed if the connector cord is not attached
to the station OR the wrong handpiece is connected.
If the sensor temperature falls below the difference between the
current temperature setting and the low-temperature alarm
tolerance, "Low Temp Error
" is displayed and the warning buzzer
sounds. When the nozzle temperature rises to a value within the
set tolerance, the buzzer will stop sounding.
"Heater Short Error
" will flash, and the buzzer will sound
continuously, when an incompatible heater circuit is inserted, or if a
foreign object has found it's way into the connector.
This is displayed when the system is unable to operate normally.
Should this error be displayed, please contact your HAKKO
representative.
43
18. TROUBLE SHOOTING GUIDE
Before checking the inside of the HAKKO FR-701 or replacing parts, be sure to disconnect the power plug.
WARNING
CHECK
: Is the power cord and/or connecting plug disconnected?
ACTION : Connect it.
CHECK
: Is the fuse blown?
ACTION : Determine why the fue blew and eliminate the cause, then replace the
fuse.
a. Is the inside of the handpiece short-circuited?
b. Is the grounding spring touching the heating element?
c. Is the heating element lead twisted and short-circuited?
Try replacing the fuse even if the cause cannot be identified.
If it still blows, return the product for repair.
CHECK
: Is the cord assembly broken? Is the heating element/
sensor broken?
ACTION : If the cord assembly is broken, replace the HAKKO FX-8801.
If the heating element / sensor is broken, replace the heating element.
●
Nothing happens when the power
switch is turned on.
●
The heater lamp lights up but the tip
does not heat up. (Soldering iron)
CHECK
:
Is the plug of the handpiece properly connected?
ACTION :
Connect it tightly.
CHECK
:
Is the nozzle or hole in the heating element clogged?
ACTION :
Clean it.
CHECK
:
Is the filter pipe full of solder?
ACTION :
Clean it.
CHECK
:
Is the ceramic paper Filter hardened?
ACTION :
Replace it with a new one.
CHECK
:
Is there a vacuum leak?
ACTION :
Check the connections and filter pipe seals and replace any worn parts.
CHECK
:
Is the heater tube or nozzle clogged?
ACTION :
Clean it.
CHECK
:
Is the plug of the handpiece properly connected?
ACTION :
Connect it tightly.
CHECK
:
Is the heating element damaged?
ACTION :
Replace it with a new one.
●
Pump does not operate. (Desoldering
Tool)
●
Solder is not being absorbed.
(Desoldering Tool)
●
The nozzle does not heat up.
(Desoldering Tool)
CHECK
: Is the tip or nozzle temperature too high?
ACTION : Set an appropriate temperature.
CHECK
: Is the tip coated with black oxide?
ACTION : Remove the black oxide. (Refer to “Tip Maintenance”.)
CHECK
: Is the tip or nozzle coated with black oxide?
ACTION : Remove the black oxide. (Refer to “Tip Maintenance”.)
CHECK
: Is the tip or nozzle temperature adjusted correctly?
ACTION : Perform the temperature adjustment.
CHECK
: Is the tip seized? Is the tip swollen because of deterioration?
ACTION : Replace the tip and the heating element.
CHECK
: Is the tip or nozzle temperature adjusted correctly?
ACTION : Perform the temperature adjustment.
●
Solder does not wet to the tip or
nozzle.
●
The tip or nozzle temperature is too
low.
●
The tip can not be pulled off.
(Soldering iron)
●
The tip or nozzle doesn’t hold the
desired temperature.
CHECK
: Is the heater broken?
ACTION : If the heater is broken, replace the heating element.
CHECK
: Is the setting value for the low-temperature alarm tolerance too low?
ACTION : Increase the setting value.
CHECK
: Is the cord assembly broken?
ACTION : If the cord assembly is broken, replace the HAKKO FX-8801.
●
The Heater-error is displayed.
(Soldering iron)
●
The tip heats up intermittently.
(Soldering iron)
NOTE :
When repairs are needed, please send both the handpiece and the station to your sales agent.