background image

41

If the refrigerator is left unused in areas where supervision is unavailable for a long time, 

make sure children will not get close to the refrigerator and the door can not be completely 

closed. 

Do not place containers with water or heavy stuffs on the refrigerator. Personal injuries may 

be caused by falling articles and electrical leakage or shock may be caused by out flowed 

water due to deterioration of insulation. 

Do not ground the refrigerator through gas pipes, water supply pipes, telephone lines or 

lightning conductors. As electric shock or other dangers may be caused. 
Do not touch electrical parts such as power plug or switches with wet hands to prevent 

electric shock. 
Hold the power plug rather than the wire when pulling the plug from the socket. As electric 

shock or fire due to short circuit may be caused. 

Pull out the power plug when the refrigerator is under abnormal performance. As electric 

shock or fire may be caused. 

Users are not allowed to dismantle, repair or refit the refrigerator by themselves. As fire or 

personal injuries may be caused due to improper operation. 
Disconnect the refrigerator when repairs or maintenance are performed on the refrigerator 

to prevent electric shock or personal injuries. 

Make sure medicines or airborne particles inside or around the refrigerator will be not be 

inhaled during maintenance as health hazard may be caused. 
The refrigerator shall be used in safe regions when toxic, harmful or radioactive articles are 

stored inside. As improper use may pose danger to human health or environment. 

Pull out the power plug if the refrigerator is out of service for long time to prevent electric 

shock, leakage or fire caused by aging power lines. 

If the power line needs to be extended, the extended line shall be no smaller than 2mm² in 

sectional area and no longer than 3m in length. Otherwise, fire or electric shock may be 

caused. 
The power line for this refrigerator is provided with a standard three wire (grounding) plug, 

which complies with 16A. Do not remove or dismantle the grounding pin of power line in 

any case. Make sure the power plug is securely and reliably plugged into the socket to 

prevent fire. 
Apply socket with ground wire to prevent electric shock. 

If the socket fails to be grounded, ground wires must be installed by technician. 

Do not use the refrigerator outdoors. Electric leakage or shock may be caused if the 

refrigerator gets wet by rainwater. 
Do not place the refrigerator in humid places or places where the refrigerator may suffer 

splashing water. To prevent electric leakage or shock due to deterioration of insulation. 

Do not pour water on the refrigerator to prevent electric shock or short circuit. 

Apply the dedicated power supply marked on the nameplate of refrigerator to prevent fire 

or electric shock. 

If voltage below 198V or above 242V is applied, automatic voltage regulator above 4000W 

and appropriate for motor load shall be installed. 

Do not store inflammable, explosive or volatile articles inside the refrigerator and do not use 

flammable sprays nearby as explosion or fire may be caused. 

4

HXC-1308B

12 Drawers

HXC-1308

Blood Bank Refrigerator 

External dimensions (W X D X H) 

mm

 

Internal dimensions (W X D X H) 

mm

 

Effective volume 

Door 

Insulating materials 

Compressor 

Shelf / Drawer

Refrigeration mode 

Outer plate / inner plate 
Condenser / evaporator 

Refrigerant 

Headlamp 

Net weight 

Temperature of temperature 

measurement box 

Rated power supply 

Rated power / current 

Alarm system 

Rechargeable battery 

1440x925x1980 

1320x700x1500 

1308L 

Electrical heating glass door 

Hard polyurethane foam (fluorine-free) 

Totally enclosed imported compressor 

12 shelves / 48 baskets 

Forced Wind Cooling Circulation 

Spraying steel plate / stainless steel plate 

Fin / fin 

Computer control system 

R134a  490g  

LED   5W

310kg

4

±1.5

220-240V~/50Hz

850W/4.2A

High-low temperature alarm, sensor fault alarm, power failure 

alarm,  low battery alarm and door opening alarm 

DC 12 V rechargeable battery 

Name 
Model 

Duration time of power failure alarm

48 hours (when battery is fully charged) 

I

Temperature controller 

USB function / temperature recorder 

Standard / standard 

Y

Electric shock resistance type 

Power connect style

Climate Type

Foaming Agent

Noise Level

4

45dB(A)

CP/IP

Note: Climate Type 4 means the temperature is +30

,the relative humidity is 55%.Technical 

information may vary from the appliance that you have just purchased due to technical improvements.

The loading of each shelf

Max:30kg

Specification

Summary of Contents for HXC-158B

Page 1: ...echnology Development Zone Qingdao 266510 P R China Web www haiermedical com Version 1st 2016 Dedicated code 0270501029 V13026 Read the Operation Manual carefully before using your appliance Keep the...

Page 2: ......

Page 3: ...ent from the figure in the manual due to product improvement The manual may be subject to changes without further notice Computer panel control digital display of temperature temperature display accur...

Page 4: ...ety Precautions Precautions for Use Product Installation Component Names Control Panel Application method Alarm Cleaning and Maintenance FAQ Refrigeration Schematic Circuit Diagram Specification 2 3 6...

Page 5: ...t to prevent personal injuries and refrigerator damage In case of flammable gas leakage such as coal gas shut off the valve of leaked gas open windows for ventilation and exhaust do not plug in or pul...

Page 6: ...gged into the socket to prevent fire Apply socket with ground wire to prevent electric shock If the socket fails to be grounded ground wires must be installed by technician Do not use the refrigerator...

Page 7: ...o children And the flammable foaming needs to be disposed by professional persons CP IP foaming materials are flammable need professional processing HXC 608B 6 Drawers HXC 608 Blood Bank Refrigerator...

Page 8: ...solvent such as gasoline Shut off the power as well as the battery switch if the refrigerator will be out of service for a long time 39 6 Precautions for Use Specification HXC 608 115V 60Hz Blood Ban...

Page 9: ...The refrigerator shall be grounded in a reliable manner If the socket is provided with grounding wire check if it is well grounded before operation If the socket is not provided with grounding wire a...

Page 10: ...ilure alarm 48 hours when battery is fully charged I Temperature controller USB function temperature recorder Optional optional Y Electric shock resistance type Power connect style Climate Type Foamin...

Page 11: ...control panel Internal fan Display panel Sensor Defrosting Control Lower temperature Upper temperature Alarm VCC GND Heating strip at the cabinet outlet Heating strip of center sill Door heating trans...

Page 12: ...the articles gradually into the refrigerator after complete examination of refrigerator 35 10 Circuit Diagram HXC 158 158B 358 358B 608 608B CN2 Cooling fan Compressor Defrosting heating strip CN2 CN...

Page 13: ...rature at one time If so the compressor may not stop for a long time with temperature reducing slowly which will reduce service life Articles must be put in batches and the temperature shall be reduce...

Page 14: ...ean data tested in the standard laboratory without noise in which the refrigerator without storage of articles is laid on the rubber pad and is steadily operated after closing the door to measure out...

Page 15: ...e for detailed information Purchasing of backup battery of the recorder Battery in the same specification and the same brand can be purchased in proper shops 9V DC In order to guarantee the reliabilit...

Page 16: ...pment and may lead to the occurrence of fault Compressor and other mechanical parts are in fully closed state and they do not need to be lubricated Clean the refrigerator Cleaning and Maintenance Comp...

Page 17: ...attery switch is on or off the remote alarm can be started The remote alarm port coordinates with the audible alarm on the refrigerator Thus the remote alarm can be stopped by pressing the key of buzz...

Page 18: ...or the refrigerator He is in charge of examining the running status of the refrigerator and making the record If the temperature inside the refrigerator is too high or too low or other abnormal phenom...

Page 19: ...ack to the normal display mode The original temperature set value 4 flickers Please do the next operation within 60s Otherwise the display panel will return to display TS SN Alarm items Buzzing Light...

Page 20: ...fter a period of Fd user parameters can be set the default value is 30 min the buzzer and remote alarm will be restarted 1Hz Continuously Buzzing 1Hz Continuously Buzzing Alarm light flashes Display b...

Page 21: ...til the pen returns to the paper At this moment the pen will pause at the most external temperature scaling line of the recording paper this scaling line does not have to be marked with temperature va...

Page 22: ...g the change of temperature in the box In order to use the disk recorder in a right and reasonable way please read the instruction bellow carefully Get familiar with your temperature recorder Adjustme...

Page 23: ...ction The computer panel has USB output function which can make use of U disk to export temperature and other test data Plug in U disk the machine begins to automatic identification and import data in...

Page 24: ...position can also be adjusted finely 3s later the scriber will slide to appointed scale according to the present perceived temperature then the calibration ends After retightening hold down bolt and...