background image

  

2. Count refrigerator accessories accompanied 

Check the articles inside the refrigerator against 
the packing list; if any difference, contact the 
after-sale service. 

3. Placing conditions 

Leave a gap of 10cm in minimum around the 
refrigerator for ventilation and heat dissipation. 

4. Adjust bracing foot 

Rotate the leveling feet with wrench in clockwise direction to extend them outward and support on 
the ground. Make sure the refrigerator will not move during operation. 

37

HXC-158B

4 Drawers

HXC-158

Blood Bank Refrigerator 

External dimensions (W X D X H) 

mm

 

Internal dimensions (W X D X H) 

mm

 

Effective volume 

Door 

Insulating materials 

Compressor 

Shelf / Drawer

Refrigeration mode 

Outer plate / inner plate 
Condenser / evaporator 

Refrigerant 

Headlamp 

Net weight 

Temperature of temperature 

measurement box 

Rated power supply 

Rated power / current 

Alarm system 

Rechargeable battery 

560×570×1530

460×370×950

158L

Electrical heating glass door 

Hard polyurethane foam (fluorine-free) 

Totally enclosed imported compressor 

Forced Wind Cooling Circulation 

Spraying steel plate / stainless steel plate 

Fin / fin 

Computer control system 

R134a 270g 

LED   3W

107kg

4

±1

220V-240V~/50Hz/60Hz

350W/2.6A

High-low temperature alarm, sensor fault alarm, power failure 

alarm, low battery alarm and door opening alarm 

DC 12 V rechargeable battery 

Name 
Model 

Duration time of power failure alarm

48 hours (when battery is fully charged) 

I

Temperature controller 

USB function / temperature recorder 

Optional / optional 

Y

Electric shock resistance type 

Power connect style

Climate Type

Foaming Agent

Noise Level

4

42dB(A)

CP/IP

Note: Climate Type 4 means the temperature is +30

,the relative humidity is 55%.Technical 

information may vary from the appliance that you have just purchased due to technical improvements.

The loading of each shelf

Max:10 kg

4 shelves / 4 baskets 

Specification

Specification

8

For safety transportation, the bottom of the 
product is installed with fixed connecting plate. 
Prior to use, users are requested to remove 
screws that connect the machine and blocking 
and then rotate the fixed connecting plate to hide 
it at the bottom of the machine. 
To handle the refrigerator before un-packaging, 
forklift or package carrier may be used. If the 
forklift is used, it shall be inserted at the bottom 
of blocking from the front or back of the 
refrigerator to move the refrigerator. If the 
package carrier is used, it shall pick up at the 
bottom of blocking and can only pick up the side 
of the refrigerator. 
After un-packaging, to handle the refrigerator, 
you may push wheels for handling. 
During handling, the inclination angle of 
refrigerator shall not be greater than 45°. 

Preparation before use

1. Remove the packing material and packaging tape 

Remove the all packing materials and packaging 
tapes for transportation. 

> 30cm from the top

> 10cm from 

the back

> 10cm from 

the left

> 10cm from 

the right

Supporting foot

Downward

upward

Summary of Contents for HXC-158B

Page 1: ...echnology Development Zone Qingdao 266510 P R China Web www haiermedical com Version 1st 2016 Dedicated code 0270501029 V13026 Read the Operation Manual carefully before using your appliance Keep the...

Page 2: ......

Page 3: ...ent from the figure in the manual due to product improvement The manual may be subject to changes without further notice Computer panel control digital display of temperature temperature display accur...

Page 4: ...ety Precautions Precautions for Use Product Installation Component Names Control Panel Application method Alarm Cleaning and Maintenance FAQ Refrigeration Schematic Circuit Diagram Specification 2 3 6...

Page 5: ...t to prevent personal injuries and refrigerator damage In case of flammable gas leakage such as coal gas shut off the valve of leaked gas open windows for ventilation and exhaust do not plug in or pul...

Page 6: ...gged into the socket to prevent fire Apply socket with ground wire to prevent electric shock If the socket fails to be grounded ground wires must be installed by technician Do not use the refrigerator...

Page 7: ...o children And the flammable foaming needs to be disposed by professional persons CP IP foaming materials are flammable need professional processing HXC 608B 6 Drawers HXC 608 Blood Bank Refrigerator...

Page 8: ...solvent such as gasoline Shut off the power as well as the battery switch if the refrigerator will be out of service for a long time 39 6 Precautions for Use Specification HXC 608 115V 60Hz Blood Ban...

Page 9: ...The refrigerator shall be grounded in a reliable manner If the socket is provided with grounding wire check if it is well grounded before operation If the socket is not provided with grounding wire a...

Page 10: ...ilure alarm 48 hours when battery is fully charged I Temperature controller USB function temperature recorder Optional optional Y Electric shock resistance type Power connect style Climate Type Foamin...

Page 11: ...control panel Internal fan Display panel Sensor Defrosting Control Lower temperature Upper temperature Alarm VCC GND Heating strip at the cabinet outlet Heating strip of center sill Door heating trans...

Page 12: ...the articles gradually into the refrigerator after complete examination of refrigerator 35 10 Circuit Diagram HXC 158 158B 358 358B 608 608B CN2 Cooling fan Compressor Defrosting heating strip CN2 CN...

Page 13: ...rature at one time If so the compressor may not stop for a long time with temperature reducing slowly which will reduce service life Articles must be put in batches and the temperature shall be reduce...

Page 14: ...ean data tested in the standard laboratory without noise in which the refrigerator without storage of articles is laid on the rubber pad and is steadily operated after closing the door to measure out...

Page 15: ...e for detailed information Purchasing of backup battery of the recorder Battery in the same specification and the same brand can be purchased in proper shops 9V DC In order to guarantee the reliabilit...

Page 16: ...pment and may lead to the occurrence of fault Compressor and other mechanical parts are in fully closed state and they do not need to be lubricated Clean the refrigerator Cleaning and Maintenance Comp...

Page 17: ...attery switch is on or off the remote alarm can be started The remote alarm port coordinates with the audible alarm on the refrigerator Thus the remote alarm can be stopped by pressing the key of buzz...

Page 18: ...or the refrigerator He is in charge of examining the running status of the refrigerator and making the record If the temperature inside the refrigerator is too high or too low or other abnormal phenom...

Page 19: ...ack to the normal display mode The original temperature set value 4 flickers Please do the next operation within 60s Otherwise the display panel will return to display TS SN Alarm items Buzzing Light...

Page 20: ...fter a period of Fd user parameters can be set the default value is 30 min the buzzer and remote alarm will be restarted 1Hz Continuously Buzzing 1Hz Continuously Buzzing Alarm light flashes Display b...

Page 21: ...til the pen returns to the paper At this moment the pen will pause at the most external temperature scaling line of the recording paper this scaling line does not have to be marked with temperature va...

Page 22: ...g the change of temperature in the box In order to use the disk recorder in a right and reasonable way please read the instruction bellow carefully Get familiar with your temperature recorder Adjustme...

Page 23: ...ction The computer panel has USB output function which can make use of U disk to export temperature and other test data Plug in U disk the machine begins to automatic identification and import data in...

Page 24: ...position can also be adjusted finely 3s later the scriber will slide to appointed scale according to the present perceived temperature then the calibration ends After retightening hold down bolt and...

Reviews: