– 27 –
3. Disconnect pressure hose from the pressure
sensor, mounted on the control board.
Remove water valve cover by pulling rear side
of the washer.
4. Disconnect the RJ45 connector by pressing
on the release tab and pushing through the
opening.
5. Disconnect the speaker assembly (for
900/905 models) by removing hex-head
screw and pressing the snap at the bottom of
the speaker housing then push through the
opening.
Backsplash Removal
Backsplash assembly contains, user interface
board, main board, RJ45 connector, speaker
assembly (900/905 models only) and voice
module on some models.
1. Remove two 1/4-in. hex-head screws that
secure the backsplash rear panel to the
backsplash assembly.
2. Remove backsplash rear panel by lifting from
the bottom and sliding to the right.
RJ45
Control Panel Housing
Rear Panel
Pressure
Sensor Hose
Water Valve
Cover
Snap
Screw
Cabinet and Structure
(
Continued next page
)
Screws
Control Panel Housing / Backsplash
Assembly
PRESSURE SENSOR
Before disconnecting hose from pressure
sensor, be sure water level in machine
is below bottom of wash basket. After
reconnecting hose, put machine in spin for at
least one minute before checking operation of