– 9 –
Electrical Specifications
AC Voltage
• Circulation Pump
: 120 VAC, .8 amps – 3.8
LRA (Locked Rotor Amps), 8GPM @ 5PSI
• Drain Pump
: 120 VAC, .3-5 ohms, .65 amps,
~70 second cycle
• Tub TCO
: 120 VAC, 210°F +/- 10°F Manual
Reset
• Main Control
: Input 120 VAC, Output 120
VAC, and Output 5 and 13.5 VDC
• Heater
DC Voltage
•
Turbidity Sensor
: 5 VDC to LED, 10k ohms
Thermistor Specifications
(in Turbidity Sensor)
Resistance Temperature
20k
50°F
11k
75°F
5.8k
100°F
3.4k
125°F
2.1k
150°F
1.3k
175°F
DC Voltage (continued)
•
Door Switch
: 13.5 VDC
• Water Valve
: 13.5 VDC, 32 ohms, .83 GPM,
~1-minute cycle time
•
User Interface (UI) Control
: 13.5 VDC (some
models have 13.5 VDC output to detergent
module)
•
Power Dry Fan:
12 - 13.5 VDC, 6,000 RPM
•
Detergent Cup
: 13.5 VDC, 25 ohms, 1
second to release detergent cup
• Rinse Aid Dispenser:
15 seconds to release
rinse aid, capacity 100 ml
• Pressure Switch
:
Heater 120 VAC
Wet
Dry
Watts
800
500
+/- 5%
Ohms
18
26.8 (hot)
14.5 (Room Temp)
+/- 5%
Amps
6.67
4.17
+/- 5%
0 - 5VDC Freq.
Output (Hz)
Internal Water Level
Description
44.27 - 43.94
Dry
40.77 - 40.44
Typical Fill
40.11 - 39.69
Flood Trip Point - Drain
Pump Runs
39.61 - 39.12
Water Over Tub Lip