CONNECT SERIES SERVICE MANUAL
71
ENGLISH
Maintenance
Compressor/Gas Liquid Separator Removal
Note: Be sure power is isolated and refrigerant is recovered before removing the gas liquid separator.
Step
Picture
Work instruction
4. Install the new gas liquid
separator
Install the gas liquid separator by
referring to the positions of entering
and leaving pipes. Braze the two
joints
Nitrogen welding: the pressure of
nitrogen is 2” to 3” W.C
Note: When brazing the pipes, do
not let the flame burn the other
components.
Tighten the screws of gas liquid
separator.
5. Secure the electric box and
Put the electric box back in place
and tighten up the screws.
Arrange the wires as original.
6. Check and open the upper
and side panels.
Check whether each component and
connection wire is well connected.
If everything is OK, install the upper,
left and right panels. Tighten up the
screws.