CONNECT SERIES SERVICE MANUAL
1
ENGLISH
Safety Notifications
PROHIBITED:
• Do not pierce or burn.
• Please note that refrigerant may be odorless.
• The appliance shall be stored in a room without continuously operating ignition sources (For example:
open flames, an operating gas appliance or an operating electric heater).
• Indoor unit adopts special joints that can’t be detached. The installation method is the same with the
common joints. Because the joint can’t be detached and if it is leaking; it must be cut out and replaced
with a braze joint.
• Using unsuitable parts or tools may lead to electric shock or fire hazard.
• Please ventilate the room immediately if refrigerant leaks during maintenance. Heavy leakage may lead to
breathing difficulty, severe injury or death.
• Disconnect power before disassembling the appliance for maintenance.
• The appliance should be maintained and cared by authorized technical personnel with necessary
qualifications.
WARNING:
NOTICE:
• If the unit location is more than 6 feet high, please wear a safety helmet, gloves and a safety belt.
• Never mix any other substances except the specified refrigerant into the refrigerant circuit.
• Check the location to see if the weight can be properly supported before installing the unit.
• Please test the system for leaks prior to charging. Leaks discovered after the unit start up require
refrigerant pump-down, leak repair and recharging. Do not allow refrigerant to leak into unventilated
spaces.
• Prepare suitable tools and protectors.
• Please isolate all power to the system while making repairs and performing maintenance.
Maintenance Safety
• This unit requires a proper earth ground per local and national electrical codes.
• Never repair the unit with wet hands. Operating the unit with wet hands may lead to electric shock.
• Isolate all power sources before cleaning the unit.
• All field installed wiring must conform to local and national electric codes.
• Brazing, welding and cutting must de done in properly ventilated areas.
• Gas appliances, heaters and other fire sources should be kept away from the installation and maintenance
site.
• Maintenance should be done according to manufacturer’s instructions.
OBSERVED:
• Check all condensate drain outlets during maintenance and operational checks.
• Unit should be installed level and on a surface that will sufficiently support it’s weight.
• Disassembly of the unit, handling of the refrigerant, oil and accessories should all be done according to
applicable local rules and regulations.
Summary of Contents for GE APPLIANCES Connect Series
Page 13: ...CONNECT SERIES SERVICE MANUAL 11 ENGLISH Troubleshooting Model AUH4860ZGDA ...
Page 22: ...CONNECT SERIES SERVICE MANUAL 20 ENGLISH Troubleshooting AUH4860ZGDAA ...
Page 84: ...CONNECT SERIES SERVICE MANUAL 82 ENGLISH Maintenance AUH4860ZGDA ...
Page 96: ...CONNECT SERIES SERVICE MANUAL ENGLISH Appendices 94 ...
Page 97: ...CONNECT SERIES SERVICE MANUAL 95 ENGLISH Appendices ...
Page 98: ...CONNECT SERIES SERVICE MANUAL 96 ENGLISH Appendices ...
Page 99: ...CONNECT SERIES SERVICE MANUAL 97 ENGLISH Appendices ...
Page 101: ......