CONNECT SERIES SERVICE MANUAL
40
ENGLISH
Maintenance
How to Replace the Compressor
Diagnosis of Compressor Failure: On Condition that the Unit CAN be Started Up
1. Start the unit if it will run and check the current of the faulted compressor. Use manifold gauges to
measure the discharge and suction pressures at the service valves. Refer to the following table based on
the recommended working current. The electric current of an inverter compressor will be different under
different rotation speed or different working conditions. If the compressor is working at 60Hz, the working
current corresponding to different condensing temperature and evaporating temperature is shown below:
Inverter compressor QXFT-F310zN450
2. Judge whether the operating noise of the compressor is normal, and whether there is a sharp noise or
obvious scraping. If there is a normal compressor working nearby, compare their operating noises.
3. Examine whether the electronic expansion valve of the outdoor unit is active and whether the 4-way valve
works or not. How to examine:
I. Electronic Expansion Valve:
The electronic expansion valve will be reset every time when the unit is
powered on or off. Touch the valve and you can feel the movement of the
valve spool. In the last stage of the reset process, you will hear the click of
the valve and feel its vibration.
Touch the electronic expansion valve:
a. Touch the top of the electronic expansion valve and you can feel its move
as it is reset upon startup.
b. Make sure the coil is fixed firmly.
II. 4-way Valve:
During normal operation, the 4 copper tubes
that connect to the valve will have different
temperatures. When the 4-way valve is working,
it will generate some noise and vibration.
This
is
the
position
of
the
4-way
valve.
Do
not
touch
it
directly
with
your
hands.
There
is
hot
refrigerant
at
the
discharge
pipe,
so
be
careful
not
to
be
scalded.
Electronic expansion
This
is
the
position
of
the
4-way
valve.
Do
not
touch
it
directly
with
your
hands.
There
is
hot
refrigerant
at
the
discharge
pipe,
so
be
careful
not
to
be
scalded.
Electronic expansion
Summary of Contents for GE APPLIANCES Connect Series
Page 13: ...CONNECT SERIES SERVICE MANUAL 11 ENGLISH Troubleshooting Model AUH4860ZGDA ...
Page 22: ...CONNECT SERIES SERVICE MANUAL 20 ENGLISH Troubleshooting AUH4860ZGDAA ...
Page 84: ...CONNECT SERIES SERVICE MANUAL 82 ENGLISH Maintenance AUH4860ZGDA ...
Page 96: ...CONNECT SERIES SERVICE MANUAL ENGLISH Appendices 94 ...
Page 97: ...CONNECT SERIES SERVICE MANUAL 95 ENGLISH Appendices ...
Page 98: ...CONNECT SERIES SERVICE MANUAL 96 ENGLISH Appendices ...
Page 99: ...CONNECT SERIES SERVICE MANUAL 97 ENGLISH Appendices ...
Page 101: ......