Maintenance
Electric Box Disassembly and Assembly
Note: Be sure power is isolated and refrigerant is recovered before removing the Electronic Expansion Valve
Step
Picture
Work instruction
3. Remove the electric
element.
Disconnect the electric element from
the wiring terminal.
Loosen screws around the electric
element with a screwdriver.
Remove the electric element from the
electric box.
4. Mount the new
electric element.
Place the electric element at the
proper position.
Tighten the screws around the electric
element with a screwdriver.
Wire the electric element to the wiring
terminal.
5. Reinstall the electric
box.
Place the electric box at the proper
position.
Tighten screws around the electric box
with a screwdriver.
Connect the power cord and control
line properly.
Reassemble the unit as before.