Assembly and Parts, Cont.

Brine Valve Housing Assembly

Current Part #

Description

Quantity

1

100237712

Piston Assembly (includes O-Ring & Spring)

1

2

100252699

O-Ring

1

3

100237707

Housing

1

4

100241875

0.5 gpm Flow Control

1

5

100242033

O-Ring

1

6

100037735

Salt Monitor Probe - JG Elbow

1

7

100238197

Screw, self-tapping

2

8

100236202

3/8-inch Locking Clip

1

100359580

Entire Assembly (all of the above parts)

Figure 16: Brine Valve Housing Assembly

100237712

  

Brine Piston

The Piston should have an O-Ring on the shaft side of the flange and a spring pressed onto a boss on 

the other side. The O-Ring should be free of defects such as cuts or debris on the shaft side.

100237707

  

Housing

Just inside the entrance hole for the Brine Piston is a concave seat area that must be free of defects such 

as nicks, indentations, or debris. This seat area ensures a leak-free seal for the static O Ring on the Brine 

Piston. If any defects are detected by visual inspection, repair or replace as needed.

100241875

  

0.5 gpm  

Flow Control

The Flow Button has two distinct and different sides. One is “flat”; the other is “concave.” The button 

should be centered in the housing opening with the four locator “ribs” with the concave side facing the 

Salt Monitor Probe.

100037735

  

Salt Monitor Probe 

- JG Elbow

The Salt Monitor Probe is held in place by two 3/4-inch self-tapping screws that engage the 

The Salt Monitor Probe is held in place by two 3/4-inch self-tapping screws that engage the 

Housing flange. An O Ring seals the Salt Monitor Probe and Housing. Place the O-Ring onto the 

Housing flange. An O Ring seals the Salt Monitor Probe and Housing. Place the O-Ring onto the 

housing end cap, lubricate with silicone grease and then using a twisting action, insert the Salt 

housing end cap, lubricate with silicone grease and then using a twisting action, insert the Salt 

Monitor Probe into the housing.  

Monitor Probe into the housing.  

Caution:

Caution:

 The 3/8-inch locking clip must be installed to prevent air from being drawn into the 

 The 3/8-inch locking clip must be installed to prevent air from being drawn into the 

appliance during brine rinse.

appliance during brine rinse.

Current Part #

Description

Quantity

1

100241865

O-Ring

1

2

100241822

Drain End Cap

1

3

100242255

Drain Line Flow Control

1

4

100241821

Retainer

1

Entire Assembly (all the above parts)

2.4 GPM = 100238229

3.0 GPM = 100241852

5.0 GPM = 100241853

7.0 GPM = 100241854

1

Figure 17: Drain End Cap Assembly

100241822

  

Drain End Cap

The Drain End Cap seals the left opening on the Main Control Valve. The opening is sealed with an 

O-Ring used as axial or “face” seal. The O-Ring sits in a groove in the End Cap. This groove must be free 

of defects such as pits or scratches and also free of debris. When assembling the End Cap to the Main 

Control Valve, care should be taken to make sure that the O-Ring stays in the groove in the End Cap. If 

misaligned, the O-Ring can become pinched and leak.

Drain Line Flow 

Control

The Drain Line Flow Control (DLFC) maintains a constant (plus or minus 10%) backwash flow rate at 

varying pressures. Care should be taken when replacing DLFCs to ensure that the correct rate is being 

used for a particular model. See 

Specifications

. When assembling the flow control, ensure that the 

rounded (radiused) side of the hole faces in toward the water flow. Available parts:

●  

●  

100242255 - 2.4*          

●  

●  

100242258 - 5.0* 

●  

●  

100242256 - 3.0*          

●  

●  

100242259 - 7.0*  

* Indicates the backwash flow rate in gpm.

100241821 Retainer

The Retainer holds the backwash Flow Control in place. One side is smooth and the other has a groove 

for a screwdriver. When assembling the retainer to the Drain End Cap, the retainer should be screwed in 

until it stops. If the retainer is not fully engaged, the Flow Control may not function properly.

Assembly and Parts, Cont.

Drain End Cap Assembly

Summary of Contents for WATERMAX SIGNATURE Series

Page 1: ...Water Conditioning Appliance SIGNATURE SERIES Owner s Manual and Installation Guide Version 1 0...

Page 2: ...ing these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise Hague Quality Water In...

Page 3: ...s potassium chloride in place of water conditioner salt A Hague dealer should be contacted before a switch is made to a salt substitute If potassium chloride is used in place of salt the technician mu...

Page 4: ...0 F 4 49 C Drain Drain the appliance to an appropriate drain such as a floor drain or washer drain that will comply with all local and state plumbing codes To prevent back siphoning provide an adequat...

Page 5: ...should make the shortest run to the suitable drain C The drain line may be elevated up to 8 feet 2 4 meters from the discharge on the appliance as long as the water pressure in your system is 40 psi...

Page 6: ...old water faucet to depressurize the lines 3 Close the faucet to eliminate any siphoning action 4 Repair all leaks 5 Turn on the water supply 6 Place the bypass in the Service position to slowly fill...

Page 7: ...jectionable concentrations of ferrous iron or sediment are present Because the blending valve is mixing raw water with softened any ferrous iron or sediment in the raw water will also be blended and r...

Page 8: ...ce Settings History No Total Regenerations Displays the number of regenerations since the last time Service Settings mode was entered Value resets to 0 once the number is viewed 0 Total Gallons Displa...

Page 9: ...m 30 psi available for proper backwash 5 Calcite will add additional hardness to water before softening 6 If iron is present in water supply use salt setting 3 or 4 7 If iron is present in the water s...

Page 10: ...tings Mode 3 is NOT recommended for residential use ST Series 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ3 2AMQ1 2APQ1 3 4 2AKQ3 2AJQ3 5 Mode 1 Yes Yes Yes Yes No Yes No No No Regeneration Frequency As Required...

Page 11: ...ttings To maintain peak performance of the appliance inspect and clean the brine tank and air check draw tube assembly annually or when sediment is present in the brine tank Modes 1 and 3 Mode 2 Salt...

Page 12: ...C Close the tap Remove Water From Media Tank A Remove the fill plug from the media tank using a 3 4 inch socket B Insert the siphon hose into the fill port C Siphon the water into the bucket down to...

Page 13: ...L x 3 ___ ppm mg L 0 2 ppm mg L x 3 0 6 ppm mg L Sulfur ___ ppm mg L x 5 ___ ppm mg L 1 0 ppm mg L x 5 5 0 ppm mg L Total compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75...

Page 14: ...the container when working with potassium permanganate Use care when removing the cover and pouring it into the feeder B Place the cover on the feeder and secure it with the three stainless steel scr...

Page 15: ...4 3 100241828 Drain End Cap and Container No DLFC See Figure 17 1 4 100241865 O Ring 2 5 100242049 Sleeve 2 6 100241807 Fill Plug 1 7 100241870 O Ring 1 8 100242050 O Ring 2 9 100241175 Bypass Valve...

Page 16: ...t draws the brine solution from the Brine Cabinet The small hole in the Injector Nozzle is the one that creates the injection stream that enters the Throat It is important that this hole is round unda...

Page 17: ...the Sensor Housing The cap is then put in place and the self tapping mount ing screw is installed A slot is provided in the cap for the wire to exit The three wire socket connector must be properly in...

Page 18: ...ft that runs through the main drive axle The Drive Gear is attached at the short end and the Magnet Disc at the other end The Slide Cam is assembled inside of the Piston Slide This Cam Shaft should tu...

Page 19: ...e and then using a twisting action insert the Salt Monitor Probe into the housing Monitor Probe into the housing Caution Caution The 3 8 inch locking clip must be installed to prevent air from being d...

Page 20: ...r No electric power at outlet Check power source Make sure outlet is not controlled by a switch Defective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14...

Page 21: ...egenerant potassium permanganate 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ Max Compensated Hardness gpg g L 90 1 5 90 1 5 90 1 5 110 1 9 904 1 5 Iron ppm 1 ferrous clear water Maximum ferrous iron reduction2 0...

Page 22: ...minimum of 200 ppm TDS 8 When adding media in the field check for proper settings See Water Conditioner Specifications above 9 Rate of flow must be verified at the end of 1 2 inch I D drain line 10 T...

Page 23: ...2022 A O Smith All Rights Reserved 100359102 DOCUMENT NUMBER RevA0123 A O Smith Water Treatment North America Inc...

Reviews: